• 1. Department of Trauma Orthopedics, Wuxi Ninth People’s Hospital, Wuxi Jiangsu, 214062, P. R. China;
  • 2. Department of Record Room, Wuxi Ninth People’s Hospital, Wuxi Jiangsu, 214062, P. R. China;
RUI Yongjun, Email: wxswkryj123@126.com; RUI Yongjun, Email: wxswkryj123@126.com
Export PDF Favorites Scan Get Citation

Objective To explore the effectiveness of using antibiotic bone cement-coated plates internal fixation technology as a primary treatment for Gustilo type ⅢB tibiofibular open fractures. Methods  The clinical data of 24 patients with Gustilo type ⅢB tibiofibular open fractures who were admitted between January 2018 and December 2021 and met the selection criteria was retrospectively analyzed. Among them, there were 18 males and 6 females, aged from 25 to 65 years with an average age of 45.8 years. There were 3 cases of proximal tibial fracture, 6 cases of middle tibial fracture, 15 cases of distal tibial fracture, and 21 cases of fibular fracture. The time from injury to emergency surgery ranged from 3 to 12 hours, with an average of 5.3 hours. All patients had soft tissue defects ranging from 10 cm×5 cm to 32 cm×15 cm. The time from injury to skin flap transplantation for wound coverage ranged from 1 to 7 days, with an average of 4.1 days, and the size of skin flap ranged from 10 cm×5 cm to 33 cm×15 cm. Ten patients had bone defects with length of 2-12 cm (mean, 7.1 cm). After emergency debridement, the tibial fracture end was fixed with antibiotic bone cement-coated plates, and the bone defect area was filled with antibiotic bone cement. Within 7 days, the wound was covered with a free flap, and the bone cement was replaced while performing definitive internal fixation of the fracture. In 10 patients with bone defect, all the bone cement was removed and the bone defect area was grafted after 7-32 weeks (mean, 11.8 weeks). The flap survival, wound healing of the affected limb, complications, and bone healing were observed after operation, and the quality of life was evaluated according to the short-form 36 health survey scale (SF-36 scale) [including physical component summary (PCS) and mental component summary (MCS) scores] at 1 month, 6 months after operation, and at last follow-up. Results All 24 patients were followed up 14-38 months (mean, 21.6 months). All the affected limbs were successfully salvaged and all the transplanted flaps survived. One case had scar hyperplasia in the flap donor site, and 1 case had hypoesthesia (grade S3) of the skin around the scar. There were 2 cases of infection in the recipient area of the leg, one of which was superficial infection after primary flap transplantation and healed after debridement, and the other was sinus formation after secondary bone grafting and was debrided again 3 months later and treated with Ilizarov osteotomy, and healed 8 months later. The bone healing time of the remaining 23 patients ranged from 4 to 9 months, with an average of 6.1 months. The scores of PCS were 44.4±6.5, 68.3±8.3, 80.4±6.9, and the scores of MCS were 59.2±8.2, 79.5±7.8, 90.0±6.6 at 1 month, 6 months after operation, and at last follow-up, respectively. The differences were significant between different time points (P<0.05). Conclusion Antibiotic bone cement-coated plates internal fixation can be used in the primary treatment of Gustilo type ⅢB tibiofibular open fractures, and has the advantages of reduce the risk of infection in fracture fixation, reducing complications, and accelerating the functional recovery of patients.

Citation: KANG Yongqiang, WU Yongwei, RUI Yongjun, ZHANG Qingqing, MA Yunhong, JIA Xueyuan, ZHANG Mingyu, ZHOU Ming, LIN Fang. Application of antibiotic bone cement-coated plates internal fixation for primary treating Gustilo type B tibiofibular open fracture. Chinese Journal of Reparative and Reconstructive Surgery, 2024, 38(4): 426-431. doi: 10.7507/1002-1892.202401099 Copy

  • Previous Article

    Clinical application of anatomical locking plate in treatment of Rockwood type -patella fractures
  • Next Article

    Effectiveness of vertical compression of locking plate combined with hollow screws in treatment of Sanders type and calcaneal fractures