• 1. Graduate Training Base of Jinzhou Medical University (Chongqing University Three Gorges Hospital), Wanzhou Chongqing, 404100, P. R. China;
  • 2. Orthopedic Center, Chongqing University Three Gorges Hospital, Wanzhou Chongqing, 404100, P. R. China;
CHEN Jian, Email: 284262176@qq.com
Export PDF Favorites Scan Get Citation

Objective  To evaluate the effectiveness of using titanium alloy trabecular bone three-dimensional (3D) printed artificial vertebral body in treating cervical ossification of the posterior longitudinal ligament (OPLL). Methods  A retrospective analysis was conducted on clinical data from 45 patients with cervical OPLL admitted between September 2019 and August 2021 and meeting the selection criteria. All patients underwent anterior cervical corpectomy and decompression, interbody bone graft fusion, and titanium plate internal fixation. During operation, 21 patients in the study group received titanium alloy trabecular bone 3D printed artificial vertebral bodies, while 24 patients in the control group received titanium cages. There was no significant difference in baseline data such as gender, age, disease duration, affected segments, or preoperative pain visual analogue scale (VAS) score, Japanese Orthopaedic Association (JOA) score, Neck Disability Index (NDI), vertebral height, and C2-7 Cobb angle (P>0.05). Operation time, intraoperative blood loss, and occurrence of complications were recorded for both groups. Preoperatively and at 3 and 12 months postoperatively, the functionality and symptom relief were assessed using JOA scores, VAS scores, and NDI evaluations. The vertebral height and C2-7 Cobb angle were detected by imaging examinations and the implant subsidence and intervertebral fusion were observed. Results  The operation time and incidence of complications were significantly lower in the study group than in the control group (P<0.05), while the difference in intraoperative blood loss between the two groups was not significant (P>0.05). All patients were followed up 12-18 months, with the follow-up time of (14.28±4.34) months in the study group and (15.23±3.54) months in the control group, showing no significant difference (t=0.809, P=0.423). The JOA score, VAS score, and NDI of the two groups improved after operation, and further improved at 12 months compared to 3 months, with significant differences (P<0.05). At each time point, the study group exhibited significantly higher JOA scores and improvement rate compared to the control group (P<0.05); but there was no significantly difference in VAS score and NDI between the two groups (P>0.05). Imaging re-examination showed that the vertebral height and C2-7 Cobb angle of the two groups significantly increased at 3 and 12 months after operation (P<0.05), and there was no significant difference between 3 and 12 months after operation (P>0.05). At each time point, the vertebral height and C2-7 Cobb angle of the study group were significantly higher than those of the control group (P<0.05), and the implant subsidence rate was significantly lower than that of the control group (P<0.05). However, there was no significant difference in intervertebral fusion rate between the two groups (P>0.05). Conclusion  Compared to traditional titanium cages, the use of titanium alloy trabecular bone 3D-printed artificial vertebral bodies for treating cervical OPLL results in shorter operative time, fewer postoperative complications, and lower implant subsidence rates, making it superior in vertebral reconstruction.

Citation: CHENG Jun, CHEN Jian, XIE Lizhong, FENG Shilong, ZHOU Jibin, ZHAN Fangbiao. Treatment of cervical ossification of posterior longitudinal ligament with titanium alloy trabecular bone three-dimensional printed artificial vertebral body. Chinese Journal of Reparative and Reconstructive Surgery, 2024, 38(5): 535-541. doi: 10.7507/1002-1892.202403003 Copy

  • Previous Article

    Application of self-stabilizing zero-profile three-dimensional printed artificial vertebral bodies for treatment of cervical spondylotic myelopathy
  • Next Article

    Analysis of imaging characteristics and effectiveness of cervical spondylotic myelopathy with cervical kyphosis