• Respiratory Department, Renmin Hospital of Wuhan University, Wuhan, Hubei 430060, P. R. China;
HU Ke, Email: hukejx@163.com
Export PDF Favorites Scan Get Citation

Objective  To assess the correlation between central sleep apnea (CSA) and serum leptin (LEP) levels in patients with chronic heart failure. Methods  The level of serum LEP and N-terminal pro-brain natriuretic peptide (NT-proBNP) were measured by forward-looking method in patients with chronic heart failure who underwent polysomnography during hospitalization from December 2015 to April 2017 in Department of Cardiology and Respiratory Medicine, Renmin Hospital of Wuhan University. And its correlation with CSA was analyzed. Patients were divided into three groups according to the left ventricular ejection fraction (LVEF), and then according to the presence or absence of CSA into CSA group and without SDB group. Results  Of the 71 patients with heart failure, 31 had LVEF≥45%, 19 were between 35% and 45% and 21 were≤35% ; 32 of whom were CSA and 39 had no SDB. The lEP concentrations in the LVEF subgroup of CSA groups were significantly lower than those in the control group without SDB, with significantly higher levels of NT-proBNP. Logistic regression showed that CSA was associated with logarithmic LEP (lnLEP) (OR=0.047, 0.030, 0.021, P<0.05). In severe heart failure (LVEF≤35%) group, high NT-proBNP was the risk of CSA (OR=5.942, P=0.045) and the incidence of CSA was as high as 71.4%, which was significantly higher than other groups. However, after adjustment for confounding factors such as age, sex and body mass index (BMI), the correlation no longer existed (OR=6.432, P=0.105). Moreover, CSA with severe cardiac insufficiency had lower LEP than those without SDB. After adjustment for confounding factors such as age, sex and BMI, CSA and lnLEP remained significantly correlated (OR=0.013, P=0.002). Meanwhile, linear correlation analysis also showed that NT-proBNP was negatively correlated with lnLEP (R=–0.751, P<0.001). After adjusting for age, sex, and BMI, this relationship still existed (R=–0.607, P=0.004). Conclusion  Decreased levels of leptin and elevated NT-proBNP in patients with chronic heart failure may indicate the presence of CSA.

Citation: LI Huimin, XIONG Mengqing, HU Ke, DONG Minglin, HU Weihua. The correlation between central sleep apnea and serum leptin levels in patients with chronic heart failure. Chinese Journal of Respiratory and Critical Care Medicine, 2018, 17(5): 499-503. doi: 10.7507/1671-6205.201712006 Copy

  • Previous Article

    Dynamic decrease of platelet count predicts poor outcome of acute respiratory distress syndrome
  • Next Article

    Effect of YC-1 on hypoxia-induced vascular adventitial fibroblast proliferation and collagen synthesis in vitro