• 1. West China Clinical Medical School, Sichuan University, Chengdu 610041, China2. West China Medical School, Sichuan University, Chengdu 610041, China3. Chinese Cochr ane Centre, West China Hospital, Sichuan University, Chengdu 610041, China4. Books and Information Centre, West China Hospital, Sichuan University, Chengdu 610041, China;
Export PDF Favorites Scan Get Citation

Objective  To evaluate the effectiveness of Medicated γ-IUD compared with other IUDs for contraception.
Methods  CBMdisc (1986 -2005), VIP (1989 -2005) , CNKI (1994-2005) , The Cochrane Library (Issue 4, 2005 ) and 10 related journals were searched for randomized controlled trials (R.CTs) and quasi-randomized controlled trials (quasi-RCTs) on the comparison between γ-IUD and other IUDs. The quality of included trials was critically appraised. RevMan 4.2.8 software was used for statistical analysis.
Results  Ten published studies with 8 381 participants were included. The results of meta-analysis were expressed with Peto OR ( cumulative pregnancy rate, cumulative expulsion rate, cumulative rate of removing for medical reasons) or OIL ( cumulative continuation rate ) and 95% CI. Compared with MSSR-165, Medicated γ-25,200 resulted in lower pregnancy rate at 1, 2, 3 years of follow-up [ with the OR (95% CI) 0. 31 (0.15,0.64) , 0. 31 (0. 17,0.54) , 0. 31 (0.19,0. 51) , respectively], lower cumulative expulsion rate in5 year follow-up [0.26 (0.17,0.40), 0.28 (0.20,0.41), 0.30 (0.21,0.42), 0.29 (0.19,0.44), 0.32 (0.21, 0. 48 ), respectively], lower cumulative rate of removing for medical reasons.after 4 year follow-up [0.57 (0.36,0. 92 ) ], and higher rate of cunmlative continuation in 5 years of follow-up 13.35 ( 2.29,4.89 ) , 2.76 ( 2.06,3, 69 ) , 2.41 (1.89,3.08), 2.22 (1.69,2.91), 1.99 (1.55,2.55), respectively]. Compared with TCu220, Medicated γ-25,200 resulted in lower cumulative pregnancy rate after follow-up 2, 3 years [ 0.46 (0.25 ,0.87 ) ; 0.48 (0.27,0. 85 ) ], lower cumulative expulsion rate after 1 year follow-up [ 0. 58 (0.35,0.97) ] , lower cumulative rate of being removed for medical reasons in5 year follow-up [0.37 (0.23,0.59), 0.38 (0.26,0.56), 0.45 (0.32,0.64), 0.47 (0.30,0.73), 0.58 (0.39,0.87), respectively ] and higher rate of cumulative continuation in 5 years of follow-up [ 2. 15 ( 1.61,2.87 ), 2.02 ( 1.56,2.63), 1.72 ( 1.34,2.20), 1.44 ( 1.08,1.91 ), 1, 39 ( 1.07,1.80), respectively]. Compared with Uterus-Cu, Medicated γ-25,200 resulted in higher rate of cumulative continuation after follow-up 1 year [ 0.51 (0.34, 0.77) ]. Compared with MLCu375, Medicated γ-25,200 resulted in lower cumulative rate of being removed for medical reasons and higher rate of cumulative continuation after follow-up for 3 years [ 0. 22 (0.09,0.52) , 2.84 ( 1.64,4. 94 )]. Compared with TCu380A, Medicated γ-25, 200 resulted in lower cumulative rate of being removed for medical reasons and higher rate of cumulative continuation in follow-up for 2 years [ 0.36 ( 0.18,0.73 ), 0.29 ( 0. 12,0.70 ) ; 3.06 ( 1.72,5.44), 3.61 (1.75,7.47) ].
Conclusions  Available evidence shows that Medicated γ-IUD has better or equal effectiveness when compared with other IUDs. However, more RCTs with high quality and longer follow up period are needed to confirm the conclusion.

Citation: KANG Yukun,WANG Li,WANG Xuan,TAN Shiqiao,TAO Kaiyu,GAN Changping,HE Ling,HUANG Lisa,LI Youping. Comparative Effectiveness of Medicated γ-IUD (Intrauterine Device) with Other IUDs for Contraception:A Systematic Review. Chinese Journal of Evidence-Based Medicine, 2006, 06(1): 30-46. doi: Copy