In the present work, Monte Carlo simulations were employed to study the characteristics of the dose distribution of high energy electron beam in the presence of uniform transverse magnetic field. The simulations carried out the transport processes of the 30 MeV electron beam in the homogeneous water phantom with different magnetic field. It was found that the dose distribution of the 30 MeV electron beam had changed significantly because of the magnetic field. The result showed that the range of the electron beam was decreased obviously and it formed a very high dose peak at the end of the range, and the ratio of maximum dose to the dose of the surface was greatly increased. The results of this study demonstrated that we could change the depth dose distribution of electron beam which is analogous to the heavy ion by modulating the energy of the electron and magnetic field. It means that using magnetic fields in conjunction with electron radiation therapy has great application prospect, but it also has brought new challenges for the research of dose algorithm.
Citation: YOUShihu, XUYun, WUZhangwen, HOUQing, GOUChengjun. Study of the Influence of Uniform Transverse Magnetic Field on the Dose Distribution of High Energy Electron Beam Using Monte Carlo Method. Journal of Biomedical Engineering, 2014, 31(6): 1350-1354. doi: 10.7507/1001-5515.20140256 Copy