1. |
Haacke E M, Xu Y, Cheng Y C N, et al. Susceptibility weighted imaging (SWI). Magnetic Resonance in Medicine, 2004, 52(3): 612-618.
|
2. |
Gilbert G, Savard G, Bard C, et al. Quantitative comparison between a multiecho sequence and a single-echo sequence for susceptibility-weighted phase imaging. Magn Reson Imaging, 2012, 30(5): 722-730.
|
3. |
Wharton S, Schafer A R. Susceptibility mapping in the human brain using threshold-based k-space division. Magnetic Resonance in Medicine, 2010, 63(5): 1292-1304.
|
4. |
Schweser F, Deistung A, Lehr B W, et al. Quantitative imaging of intrinsic magnetic tissue properties using MRI signal phase: an approach to in vivo brain Iron metabolism? Neuroimage, 2011, 54(4): 2789-2807.
|
5. |
Rydell J, Knutsson H, Pettersson J, et al. Phase sensitive reconstruction for water/fat separation in MR imaging using inverse gradient//Ayache N, Ourselin S, Maeder A. Medical Image Computing and Computer-Assisted Intervention-MICCAI 2007. MICCAI 2007. Lecture Notes in Computer Science, vol 4791. Berlin, Heidelberg: Springer, Berlin, Heidelberg, 2007: 210-218.
|
6. |
Bagher-Ebadian H, Jiang Quan, Ewing J R. A modified Fourier-based phase unwrapping algorithm with an application to MRI venography. Journal of Magnetic Resonance Imaging, 2008, 27(3): 649-652.
|
7. |
Goldstein R M, Zebker H A, Werner C L. Satellite radar interferometry: Two-dimensional phase unwrapping. Radio Science, 1988, 23(4): 713-720.
|
8. |
Cusack R, Huntley J M, Goldrein H T. Improved noise-immune phase-unwrapping algorithm. Appl Opt, 1989, 28(16): 781-789.
|
9. |
Zhao Ming, Huang Lei, Zhang Qican, et al. Quality-guided phase unwrapping technique: comparison of quality maps and guiding strategies. Appl Opt, 2011, 50(33): 6214-6224.
|
10. |
Witoszynskyj S, Rauscher A, Reichenbach J R, et al. Phase unwrapping of MR images using Phi UN--a fast and robust region growing algorithm. Med Image Anal, 2009, 13(2): 257-268.
|
11. |
Jenkinson M. Fast, automated, N-dimensional phase-unwrapping algorithm. Magnetic Resonance in Medicine, 2003, 49(1): 193-197.
|
12. |
Ghiglia D C, Romero L A. Robust two-dimensional weighted and unweighted phase unwrapping that uses fast transforms and iterative methods. Journal of the Optical Society of America A, 1994, 11(1): 107-117.
|
13. |
Chan T F, Vese L A. Active contours without edges. IEEE Trans Image Process, 2001, 10(2): 266-277.
|
14. |
Ye Xiufen, Zhang Zhehui, Liu P X, et al. Sonar image segmentation based on GMRF and level-set models. Ocean Engineering, 2010, 37(10): 891-901.
|
15. |
Henkelman R M. Measurement of signal Intensities in the presence of noise in MR images. Med Phys, 1985, 12(2): 232-233.
|
16. |
Gudbjartsson H, Patz S. The Rician distribution of noisy MRI data. Magnetic Resonance in Medicine, 1996, 34(2): 910-914.
|
17. |
Manjón J V, Coupé P, Buades A. MRI noise estimation and denoising using non-local PCA. Med Image Anal, 2015, 22(1): 35-47.
|
18. |
Buades A, Coll B, Morel J M. A review of image denoising algorithms, with a new one. Multiscale Model Simul, 2005, 4(2): 490-530.
|
19. |
Zhang Lei, Dong Weisheng, Zhang D, et al. Two-stage image denoising by principal component analysis with local pixel grouping. Pattern Recognit, 2010, 43(4): 1531-1549.
|
20. |
Manjón J V, Coupé P, Buades A, et al. New methods for MRI denoising based on sparseness and self-similarity. Med Image Anal, 2012, 16(1): 18-27.
|
21. |
Coupe P, Yger P, Prima S, et al. An optimized blockwise nonlocal means denoising filter for 3-D magnetic resonance images. IEEE Trans Med Imaging, 2008, 27(4): 425-441.
|
22. |
Bouthemy P. Adaptive spatio-temporal restoration for 4D fluorescence microscopic imaging. Lect Notes Comput Sci, 2005, 8(Pt 1): 893-901.
|
23. |
Buades A, Coll B, Morel J M. Nonlocal image and movie denoising. Int J Comput Vis, 2008, 76(2): 123-139.
|