WANG Yabo 1,2 , LIU Jie 1,2 , GAO Lilan 1,2,3,4 , TAN Yansong 1,2 , CHEN Ruiqi 1,2 , ZHANG Chunqiu 1,2,3,4
  • 1. Tianjin Key Laboratory for Advanced Mechatronic System Design and Intelligent Control, School of Mechanical Engineering, Tianjin University of Technology, Tianjin 300384, P. R. China;
  • 2. National Demonstration Center for Experimental Mechanical and Electrical Engineering Education, Tianjin University of Technology, Tianjin 300384, P. R. China;
  • 3. Tianjin Key Laboratory of Bone Implant Interface Functionalization and Personality, Tianjin 300190, P. R. China;
  • 4. Just Medical Devices (Tianjin) Co., LTD, Tianjin 300190, P. R. China;
LIU Jie, Email: liujiejane@163.com; GAO Lilan, Email: gaolilan780921@163.com
Export PDF Favorites Scan Get Citation

Superficial cartilage defect is an important factor that causes osteoarthritis. Therefore, it is very important to investigate the influence of superficial cartilage defects on its surface morphology and mechanical properties. In this study, the knee joint cartilage samples of adult pig were prepared, which were treated by enzymolysis with chymotrypsin and physical removal with electric friction pen, respectively. Normal cartilage and surface treated cartilage were divided into five groups: control group (normal cartilage group), chymotrypsin immersion group, chymotrypsin wiping group, removal 10% group with electric friction pen, and removal 20% group with electric friction pen. The surface morphology and structure of five groups of samples were characterized by laser spectrum confocal microscopy and environmental field scanning electron microscopy, and the mechanical properties of each group of samples were evaluated by tensile tests. The results show that the surface arithmetic mean height and fracture strength of the control group were the smallest, and the fracture strain was the largest. The surface arithmetic mean height and fracture strength of the removal 20% group with electric friction pen were the largest, and the fracture strain was the smallest. The surface arithmetic mean height, fracture strength and fracture strain values of the other three groups were all between the above two groups, but the surface arithmetic mean height and fracture strength of the removal 10% group with electric friction pen, the chymotrypsin wiping group and the chymotrypsin soaking group decreased successively, and the fracture strain increased successively. In addition, we carried out a study on the elastic modulus of different groups, and the results showed that the elastic modulus of the control group was the smallest, and the elastic modulus of the removal 20% group with electric friction pen was the largest. The above study revealed that the defect of the superficial area of cartilage changed its surface morphology and structure, and reduced its mechanical properties. The research results are of great significance for the prevention and repair of cartilage injury.

Citation: WANG Yabo, LIU Jie, GAO Lilan, TAN Yansong, CHEN Ruiqi, ZHANG Chunqiu. Effects of removing superficial layer of cartilage on the surface morphology and mechanical behavior of cartilage. Journal of Biomedical Engineering, 2024, 41(2): 328-334. doi: 10.7507/1001-5515.202308032 Copy

  • Previous Article

    Biological function of bladder smooth muscle cells regulated by multi-modal biomimetic stress
  • Next Article

    Screening of place cell and analysis of its influencing factors for pigeons