• Department of Radiology, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, P. R. China;
LiZhenlin, Email: lzlcd01@126.com
Export PDF Favorites Scan Get Citation

Objective To discuss the value of dual-source CT Flash scanning in reducing the dose of radiation in 3D cardiac imaging. Method We collected 60 patients from March to August 2014 who should undergo cardiac 3D CT scanning before radiofrequency ablation. They were randomly divided into group A and B with 30 in each. Patients in group A underwent flash technology scanning, while those in group B accepted conventional retrospective electrocardiography-gated scanning. CARE Dose techniques were used to collect data. Scanning parameters were the same for both groups:collimation was 128×0.6 mm, reconstruction thickness was 0.75 mm, reconstruction interval was 0.7 mm, and field of view was 180-200 mm. After image acquisition, we measured the CT values and noise of left atrium and various branches of the pulmonary veins (upper left, lower left, upper right, and lower right). Statistical software was used for the two groups of images to analyze the carrier noise ratio (CNR), signal noise ratio (SNR), blinded scores, computed tomography dose index (CTDIvol), and dose-length product (DLP) of the left atrium and pulmonary vein. Results CNR and SNR of the left atrium and various pulmonary veins between the two groups had no significant differences (P>0.05) . Blinded scores between the two groups were not significantly different (P>0.05) . CTDIvol in group A and group B was respectively (2.92±0.38) and (20.15±12.09) mGy, with a significant difference (t=?7.803, P<0.001) . DLP of group A was (59.30±6.67) mGy·cm, significantly lower than that in group B [(334.43±216.71) mGy·cm] (t=?6.591, P<0.001) . Flash-efficient radiation dose was (0.83±0.94) mSv in group A, far below that in group B [(4.53±3.03) msv], and the difference was statistically significant (t=?6.684, P<0.001) . Conclusions Dual-source CT Flash technology applied in 3D cardiac scanning can reduce radiation dose as well as meet the needs of image diagnosis.

Citation: ZouMeng, LiZhenlin, PanXuelin, YuanYuan, QianLingling. Application of Dual-source Low-dose CT Flash Scanning in 3D Cardiac Imaging. West China Medical Journal, 2016, 31(3): 531-535. doi: 10.7507/1002-0179.201600140 Copy

  • Previous Article

    Features of Allergic Bronchopulmonary Aspergillosis on X-ray and Computed Tomography
  • Next Article

    Investigation on the Examinees' Cognitive Level of X-ray Radiation