• Department of Oncology, Nuclear Industry 416 Hospital, Chengdu, Sichuan 610000, P. R. China;
Export PDF Favorites Scan Get Citation

Objective To compare the radiation dose distribution in irradiated target area and organs at risk among conventional radiotherapy, conformal radiotherapy and semi-field conformal radiotherapy in Graves' ophthalmopathy patients. Methods Thirty patients with Grave's ophthalmopathy treated between January 2010 and December 2012 were included in this study.CT scan was performed to obtain images of each patients; three-dimensional planning system (3D-TPS) was done to design conventional radiotherapy, conformal radiotherapy and semi-field conformal radiotherapy for each patient.Then, we counted the standard deviation of study parameters for each radiotherapy technique, and the results were compared among the three groups. Results Average irradiation dose in target area of patients accepting conventional irradiation, conformal irradiation and semi-field conformal irradiation therapy was not significantly different (P > 0.05).V95 and the conformity index values of conformal irradiation and semi-field conformal irradiation therapy were better than those of the conventional irradiation therapy (P < 0.001), while no significant difference between conformal irradiation and semi-field conformal irradiation therapy was detected (P > 0.05).Patients accepting conventional irradiation got the highest cumulative irradiation dose in eye lens, while patients accepting semi-field conformal irradiation therapy got the lowest irradiation dose in eye lens, and the differences were significant (P < 0.05).Patients accepting conventional irradiation got the highest cumulative irradiation dose in pituitary, while cumulative irradiation dose in pituitary in patients accepting conformal irradiation and semi-field conformal irradiation therapy was not significantly different (P > 0.05). Conclusions Conformal irradiation and semi-field conformal irradiation techniques are superior to conventional irradiation technique, with a better target conformal degree and higher does distribution in target area, as well as a lower radiation dose in normal tissues surrounding target area.Semi-field conformal irradiation technique has a better performance than conformal irradiation therapy in eye lens protection.

Citation: HeDan, FuBo. Dosimetric Study of Three Different Irradiation Techniques in Graves' Ophthalmopathy Radiotherapy. West China Medical Journal, 2016, 31(12): 2000-2003. doi: 10.7507/1002-0179.201600548 Copy

  • Previous Article

    Study on Preoperative Observation of Cataract Patients' Zonules by Ultrasound Biomicroscopy
  • Next Article

    Effects of the Operation of Nuclear Medicine Technologists on the Quality and Efficiency of Whole-body Bone Imaging