• Department of Orthopedics, West China Hospital, Sichuan University, Chengdu Sichuan, 610041, P. R. China;
HUANGFuguo, Email: huang-f-g@163.com
Export PDF Favorites Scan Get Citation

Objective To investigate the effectiveness of limited internal fixation combined with hinged super-articular external fixator to treat type C3 fracture of the distal humerus. Methods Between September 2007 and November 2012, 37 cases of type C3 fracture of the distal humerus were treated. There were 22 males and 15 females with an average age of 43.6 years (range, 22-66 years). The causes were accident injury in 24 cases, falling injury in 5 cases, falling from height in 4 cases, heavy crush injury in 2 cases, machine injury in 1 case, and other injury in 1 case. There were 22 cases of open injury and 15 cases of closed injury. The time from injury to operation was 3-46 hours (mean, 18 hours). Results Needle tract reaction and incision infection occurred in 3 cases and 1 case respectively, healing of incision by first intension was obtained in the other cases. Thirty-six patients were followed up 9-48 months (mean, 25.4 months). Heterotopic ossification occurred in 3 cases after operation and no recurrence was found by release after fracture healing. Fractures healed in the other patients after 6-14 months (mean, 9 months) of operation except 1 patient who suffered chronic osteomyelitis. One patient had delayed ulnar neuritis at 12 months after operation, and the nerve function returned to normal after the ulnar nerve transposition. There was no bone ischemic necrosis, elbow joint instability, or loosening of internal fixation. At last follow-up, the average range of motion of injured elbow was 105.0° in flexion,-25.0° in extension, 69.2° in pronation, and 75.6° in supination. According to Mayo elbow joint function score (MEPS) and disability of arm shoulder and hand (DASH) score, the results were excellent in 22 cases, good in 8 cases, fair in 4 cases, and poor in 2 cases with an excellent and good rate of 83.3%; and according to Cassebaum elbow joint function score, the results were excellent in 21 cases, good in 7 cases, fair in 5 cases, and poor in 3 cases with an excellent and good rate of 77.8%. Conclusion A combination of limited internal fixation and hinged super-articular external fixator has satisfactory clinical curative effect for type C3 fractures of the distal humerus, relatively few complications.

Citation: XULong, ZHAOSichun, WUShizhou, GUOJinhai, HUANGFuguo. EFFECTIVENESS OF LIMITED INTERNAL FIXATION COMBINED WITH HINGED SUPER-ARTICULAR EXTERNAL FIXATOR FOR TYPE C3 FRACTURE OF DISTAL HUMERUS IN ADULT. Chinese Journal of Reparative and Reconstructive Surgery, 2015, 29(6): 678-682. doi: 10.7507/1002-1892.20150147 Copy

  • Previous Article

    EFFECT OF DIFFERENT NECK-SHAFT ANGLE ON EFFICACY IN TREATMENT OF PROXIMAL HUMERAL FRACTURES WITH LOCKING PLATE
  • Next Article

    EFFECTIVENESS COMPARISON OF EXTERNAL FIXATION AND VOLAR LOCKING COMPRESSION PLATE IN TREATMENT OF DISTAL RADIUS FRACTURES OF TYPE C