• 1. Department of Orthopedic Trauma and Microsurgery, the Orthopedic Hospital Affiliated to Guangdong University of Traditional Chinese Medicine, Guangzhou Guangdong, 510240, P. R. China;
  • 2. Department of Hand Surgery, Orthopedic Trauma and Microsurgery, the First Affiliated Hospital of Sun Yat-sen University, Guangzhou Guangdong, 510240, P. R. China;
QIJian, Email: speedsnow@126.com
Export PDF Favorites Scan Get Citation

Objective To evaluate the effectiveness of one stage vacuum sealing drainage (VSD) combined with bi-pedicle sliding flap transplantation in repairing open tibiofibular fracture and soft tissue defects of the lower leg. Methods Twenty-five patients with open tibiofibular fracture and soft tissue defects of the lower leg were treated by VSD combined with bi-pedicle sliding flap transplantation between January 2012 and July 2014. There were 18 males and 7 females, aged 12-65 years (mean, 35.2 years). The injury causes included traffic accident injury (20 cases), falling injury from height (3 cases), and heavy pound injury (2 cases). The left side was involved in 14 cases, the right side in 8 cases, and both sides in 3 cases. According to Gustilo classification, injury was rated as type II (6 lower extremities), type III a (19 lower extremities), and type III b (3 lower extremities). The anterior tibial defect area after debridement ranged from 6 cm×3 cm to 12 cm×5 cm. The course of injury and admission was 1-18 hours (mean, 4.5 hours). An anterior tibial bi-pedicle sliding flap of 24 cm×6 cm to 48 cm×8 cm was designed to cover the wound and tibia fracture was fixed with minimally invasive internal fixation. After suturing the anterior tibial wound without tension, the flap was transferred forward. The exposed fibula was fixed with reconstruction plate. The remained wound was covered by VSD. Continuously antibiotic saline irrigation was applied postoperatively. After 15 days, the VSD dressing was removed and free skin graft was used to cover the remained wound. Results After the VSD dressing was removed, the wounds and tension-reduced wound of 18 lower extremities completely healed. Unhealing wounds were covered by skin graft in 9 lower extremities. Infection occurred in 1 lower extremity and was cured after treated with antibiotics. All the wounds healed and flaps survived. The patients were followed up 6-24 months (mean, 18 months). The fractures union was confirmed by X-ray and the average union time was 3.2 months (range, 2.5-5 months). Conclusion The application of one stage VSD combined with bi-pedicle sliding flap transposition is a simple and safe treatment regimen for Gustilo type II-IIIa open tibiofibular fracture and soft tissue defects of the lower leg. It has the advantages of few complications and low costs, short hospitalization, and good effectiveness.

Citation: YEGuoqiang, FUGuo, QIJian. APPLICATION OF ONE STAGE VACUUM SEALING DRAINAGE COMBINED WITH BI-PEDICLE SLIDING FLAP TRANSPLANTATION FOR OPEN TIBIOFIBULAR FRACTURE AND SOFT TISSUE DEFECTS OF THE LOWER LEG. Chinese Journal of Reparative and Reconstructive Surgery, 2015, 29(8): 955-958. doi: 10.7507/1002-1892.20150206 Copy

  • Previous Article

    EFFECTS OF FEMORAL TUNNEL POSITION ON KNEE FUNCTION AFTER MEDIAL PATELLOFEMORAL LIGAMENT RECONSTRUCTION
  • Next Article

    APPLICATION RESEARCH OF USING OSTEOTOMY GUIDE DEVICE IN OSTETOMY WITH MULTIPLE DRILL HOLES