• Department of Orthopaedics, Urumqi General Hospital of Military, Urumqi Xinjiang, 830000, P.R.China;
XU Gang, Email: jxugang@sina.com
Export PDF Favorites Scan Get Citation

Objective To investigate the effectiveness of arthroscopic all-inside combined with outside-in “suture loop” repair for meniscus bucket-handle tear (BHT).Methods Between August 2016 and May 2019, 44 case of meniscus BHT were treated with arthroscopic all-inside combined outside-in “suture loop”. There were 29 males and 15 females with an average age of 26.6 years (range, 18-42 years). The causes of injury included sports injury in 31 cases, falling injury in 7 cases, and sprain in 6 cases. There were 32 cases of medial meniscus posterior horn tears and 12 cases of lateral meniscus posterior horn tears. The disease duration ranged from 6 weeks to 3 months. Thirty-three cases were complicated with anterior cruciate ligament rupture. All patients had normal lower limb alignment. The preoperative Lysholm score was 42.1±9.1. According to the evaluation criteria of MRI and Barrett et al., the healing of meniscus was evaluated, and the effectiveness was evaluated by Lysholm score.Results All the 44 patients were followed up 8-36 months with an average of 16.8 months. At last follow-up, according to the evaluation criteria of Barrett et al., 39 cases were clinically healed, 5 cases were not healed, the clinical healing rate was 88.6%; according to MRI evaluation, 32 cases were completely healed, 7 cases were partially healed, and 5 cases were not healed, the total healing rate was 88.6%, and the complete healing rate was 72.7%. Lysholm score was 87.8±4.8, which was significantly different from that before operation (t=31.060, P=0.000).Conclusion Arthroscopic all-inside combined with outside-in “suture loop” repair is a reliable and effective method for the meniscus BHT, which can obtain good joint function.

Citation: Maimaitikelimu·tusongjiang, JIA Yong, XU Gang, HE Chunqing, ZHANG Fei, LIU Jian, WANG Pengbo, Wumuerbieke. Clinical observation of arthroscopic all-inside combined with outside-in “suture loop” repair for meniscus bucket-handle tear. Chinese Journal of Reparative and Reconstructive Surgery, 2020, 34(10): 1238-1242. doi: 10.7507/1002-1892.202003132 Copy

  • Previous Article

    Optimization location of femoral attachment in medial patellofemoral ligament reconstruction assisted with arthroscopy for patellar dislocation
  • Next Article

    Clincal observation of non-absorbable suture cerclage combined with patella claw fixation for treatment of inferior patella fractures