• Department of Orthopedics and Soft Tissue, the Affiliated Cancer Hospital of Zhengzhou University (Henan Cancer Hospital), Zhengzhou Henan, 450003, P. R. China;
ZHANG Peng, Email: zdzp@zzu.edu.cn
Export PDF Favorites Scan Get Citation

Objective  To investigate the clinical application and effectiveness of three-dimensional (3D) printed customized prosthesis with preserved epiphysis and articular surface in the reconstruction of large bone defects in treatment of adolescent femoral malignant tumors. Methods  The clinical data of 10 adolescent patients with femoral primary malignant tumor who met the selection criteria and underwent limb salvage surgery with 3D printed customized prosthesis with preserved epiphysis and articular surface between January 2020 and October 2021 were retrospectively analyzed. There were 6 males and 4 females with an average age of 12.5 years ranging from 7 to 18 years. There were 8 cases of osteosarcoma and 2 cases of Ewing’s sarcoma. Enneking stage was Ⅱb. The length of the lesions ranged from 76 to 240 mm, with an average of 138.0 mm. The length of osteotomy (i. e. length of customized prosthesis) ranged from 130 to 275 mm, with an average of 198.5 mm; the distance between distal osteotomy end and epiphyseal line ranged from 0 to 15 mm, with an average of 8.8 mm; the bone defect after osteotomy accounted for 37.36% to 79.02% of the total length of the lesion bone, with a mean of 49.43%. The operation time, intraoperative blood loss, complications, tumor outcome (refered to RESIST1.1 solid tumor efficacy evaluation criteria), and limb length discrepancy were recorded. The Musculoskeletal Cancer Society (MSTS) 93 score was used to evaluate the function at 6 months after operation, and visual analogue scale (VAS) score was used to evaluate the pain before and after operation. Results  The operation was successfully performed in all the 10 patients, and the postoperative pathological results were consistent with the preoperative pathological results. The operation time was 165-440 minutes, with an average of 263 minutes; and the intraoperative blood loss was 100-800 mL, with an average of 350 mL. All patients were followed up 7-26 months, with an average of 11.8 months. No tumor was found on the osteotomy surface; the customized prosthesis were firmly installed and closely matched with the retained articular surface. The tumor outcome of neoadjuvant chemotherapy was stable in 4 cases and partial remission in 6 cases. No local recurrence or distant metastasis was found in 9 cases after postoperative adjuvant chemotherapy; pulmonary metastasis was found in 1 case at 12 months after operation. Two patients had local incision fat liquefaction, superficial infection, and delayed healing at 14 days after operation; 1 patient had local bone absorption at the contact surface of the prosthesis, and the screw and prosthesis did not loosen at 7 months after operation; the other patients had good incision healing, with no infection, prosthesis loosening, fracture, or other complications. At 6 months after operation, the MSTS93 score was 19-28, with an average of 24.1; 8 cases were excellent and 2 cases were good. The VAS score was 0.9±1.0, which significantly improved when compared with before operation (5.9±1.0) (t=23.717, P<0.001). The height of the patients increased by 1-12 cm, with an average of 4.6 cm. At last follow-up, 4 patients had limb length discrepancy, with a length difference of 1 cm in 2 cases and 2 cm in 2 cases. Conclusion  The application of 3D printed customized prosthesis in the resection and reconstruction of adolescents femoral primary malignant tumors can achieve the purpose of preserving epiphysis and articular surface, and obtain good effectiveness.

Citation: NIU Xiaoying, GAO Shilei, QU Guoxin, LI Zhehuang, LIANG Xiaoxiao, YAO Weitao, ZHANG Peng. Application of three-dimensional printed customized prosthesis with preserved epiphysis and articular surface in the reconstruction of large bone defects in treatment of adolescent femoral malignant tumors. Chinese Journal of Reparative and Reconstructive Surgery, 2022, 36(11): 1374-1380. doi: 10.7507/1002-1892.202206058 Copy

  • Previous Article

    Study of characteristics and treatment of “kissing fracture” of humeroradial joint
  • Next Article

    Low molecular weight heparin combined with aspirin to prevent perioperative venous thromboembolism in patients with splenic rupture and lower extremity fracture