- 1. Medical School of Chinese PLA, Beijing 100853, P. R. China;
- 2. Department of Vascular and Endovascular Surgery, The First Medical Centre, Chinese PLA General Hospital, Beijing 100853, P. R. China;
The treatment of aortic dissection has already shifted to endovascular strategies. However, with the evolution of this disease and a deeper understanding of it, experts from various countries have developed a series of innovative endovascular techniques and devices in areas such as lumen reconstruction, false lumen embolization, entry sealing, and branch arteries reconstruction, targeting the long-term complication of chronic post-dissection thoracoabdominal aortic aneurysm. The past few decades have seen that Chinese vascular surgeons have gradually emerged on the world stage and contributed multiple “Chinese solutions” for post-dissection thoracoabdominal aortic aneurysm. The author in this review intends to provide an overview of these techniques and devices mentioned above.
Citation: WANG Jiabin, GUO Wei. Progress in total endovascular aortic repair of chronic post-dissection thoracoabdominal aortic aneurysm. CHINESE JOURNAL OF BASES AND CLINICS IN GENERAL SURGERY, 2024, 31(6): 649-655. doi: 10.7507/1007-9424.202405020 Copy
1. | Writing Committee Members; Isselbacher EM, Preventza O, et al. 2022 ACC/AHA guideline for the diagnosis and management of aortic disease: A report of the American Heart Association/American College of Cardiology Joint Committee on Clinical Practice Guidelines. J Thorac Cardiovasc Surg, 2023, 166(5): e182-e331. doi: 10.1016/j.jtcvs.2023.04.023. |
2. | Xu H, Xiong J, Han X, et al. Computed tomography-based hemodynamic index for aortic dissection. J Thorac Cardiovasc Surg, 2021, 162(2): e165-e176. doi:10.1016/j. jtcvs. 2020. 02. 034. |
3. | Fattori R, Montgomery D, Lovato L, et al. Survival after endovascular therapy in patients with type B aortic dissection: a report from the International Registry of Acute Aortic Dissection (IRAD). JACC Cardiovasc Interv, 2013, 6(8): 876-882. |
4. | Qin YL, Deng G, Li TX, et al. Risk factors of incomplete thrombosis in the false lumen after endovascular treatment of extensive acute type B aortic dissection. J Vasc Surg, 2012, 56(5): 1232-1238. |
5. | Ge YY, Rong D, Ge XH, et al. The 301 classification: a proposed modification to the stanford type B aortic dissection classification for thoracic endovascular aortic repair prognostication. Mayo Clin Proc, 2020, 95(7): 1329-1341. |
6. | Lombardi JV, Gleason TG, Panneton JM, et al. Five-year results of the STABLEⅡ study for the endovascular treatment of complicated, acute type B aortic dissection with a composite device design. J Vasc Surg, 2022, 76(5): 1189-1197. |
7. | Wang R, Kan Y, Yang M, et al. Clinical results and aortic remodeling after endovascular treatment for complicated type B aortic dissection with the “Fabulous” stent system. Front Cardiovasc Med, 2022, 9: 817675. doi: 10.3389/fcvm.2022.817675. |
8. | Żołnierczuk M, Miśkiewicz M, Paduch J, et al. Questionable long-term results of the extended provisional extension to induce complete attachment (E-PETTICOAT) technique in the management of chronic type B aortic dissection. Ann Vasc Surg, 2023, 89: 210-215. |
9. | Mascia D, Rinaldi E, Salvati S, et al. Thoracic endovascular aortic repair with additional distal bare stents in type B aortic dissection does not prevent long-term aneurysmal degeneration. J Endovasc Ther, 2021, 28(3): 425-433. |
10. | Wamala I, Nazari-Shafti MTZ, Heck R, et al. Aortic remodelling and late outcomes following thoracic endovascular repair with a bare-metal stent distal extension among patients with complicated type-B aortic dissection. Interact Cardiovasc Thorac Surg, 2022, 35(5): ivac244. doi: 10.1093/icvts/ivac244. |
11. | Maurin A, Jacquier A, Bartoli A, et al. STABILISE (stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair) is associated with good anatomical results on the distal thoracoabdominal aorta at 2 years. J Endovasc Ther, 2024: 15266028241232923. doi: 10.1177/15266028241232923. |
12. | Bayfield NGR, Bennett A, Ritter JC. Stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair (STABILISE): A meta-analysis of early outcomes. Ann Vasc Surg, 2024, 98: 146-154. |
13. | Vecchini F, Haupert G, Baudry A, et al. Risk factors for incomplete aortic remodeling with stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair for complicated aortic dissection: results of a multicenter study. J Endovasc Ther, 2024, 31(1): 69-79. |
14. | de Beaufort HWL, Vos JA, Heijmen RH. Initial single-center experience with the knickerbocker technique during thoracic endovascular aortic repair to block retrograde false lumen flow in patients with type B aortic dissection. J Endovasc Ther, 2022: 15266028221134889. doi: 10.1177/15266028221134889. |
15. | Blitzer DN, Pereira GA, Drucker C, et al. The Caged Knickerbocker: A novel modification to targeted false lumen management in complex aortic dissection. Vasc Endovascular Surg, 2023, 57(3): 197-202. |
16. | Rohlffs F, Tsilimparis N, Panuccio G, et al. The Knickerbocker Technique: Technical aspects and single-center results of a new endovascular method for false lumen occlusion in chronic aortic dissection. J Endovasc Ther, 2023, 30(4): 609-614. |
17. | Zha B, Xu G, Zhu H, et al. Endovascular repair of type B aortic dissection with the restrictive bare stent technique: morphologic changes, technique details, and outcomes. Ther Clin Risk Manag, 2018, 14: 1993-2002. |
18. | Li X, Zhang Y, Sun Z, et al. Prevention of distal stent graft-induced new entry after endovascular repair for type B aortic dissection: A retrospective cohort study. J Thorac Cardiovasc Surg, 2024, 167(1): 28-38. |
19. | Feng J, Lu Q, Zhao Z, et al. Restrictive bare stent for prevention of stent graft-induced distal redissection after thoracic endovascular aortic repair for type B aortic dissection. J Vasc Surg, 2013, 57(2 Suppl): 44S-52S. doi: 10.1016/j.jvs.2012.06.117. |
20. | Zhao Y, Yin H, Chen Y, et al. Restrictive bare stent prevents distal stent graft-induced new entry in endovascular repair of type B aortic dissection. J Vasc Surg, 2018, 67(1): 93-103. |
21. | Kazimierczak A, Rynio P, Jędrzejczak T, et al. Expanded Petticoat technique to promote the reduction of contrasted false lumen volume in patients with chronic type B aortic dissection. J Vasc Surg, 2019, 70(6): 1782-1791. |
22. | Kazimierczak A, Jedrzejczak T, Rynio P, et al. Favorable remodeling after hybrid arch debranching and modified provisional extension to induce complete attachment technique in type A aortic dissection: A case report. Medicine, 2018, 97(37): e12409. doi: 10.1097/MD.0000000000012409. |
23. | Kazimierczak A, Rynio P, Jędrzejczak T, et al. Aortic remodeling after extended PETTICOAT technique in acute aortic dissection type Ⅲ B. Ann Vasc Surg, 2020, 66: 183-192. |
24. | Mufty H, Katsargyris A, Houthoofd S, et al. Technical note: dissection flap perforation with use of a TIPS-needle during fenestrated endografting for post-dissection thoracoabdominal aneurysms. Cardiovasc Inter Rad, 2018, 41(6): 964-967. |
25. | Correia R, Alves G, Bento R, et al. Dissection flap fenestration with a transjugular intrahepatic portosystemic shunt needle: An adjuvant technique in endovascular treatment of post-dissection thoraco-abdominal aortic aneurysms. EJVES Vasc Forum, 2021, 52: 38-40. |
26. | Tashiro J, Baqai A, Goldstein L J, et al. “Cheese wire” fenestration of a chronic aortic dissection flap for endovascular repair of a contained aneurysm rupture. J Vasc Surg, 2014, 60(2): 497-499. |
27. | Iwakoshi S, Watkins CA, Ogawa Y, et al. “Cheese Wire” fenestration of dissection intimal flap to facilitate thoracic endovascular aortic repair in chronic dissection. J Vasc Interv Radiol, 2020, 31(1): 150-154. |
28. | 杨鑫, 戴向晨, 朱杰昌, 等. Cheese wire结合开窗腔内修复术重建内脏动脉治疗胸腹主动脉夹层动脉瘤一例. 中华血管外科杂志, 2018, 3(2): 120-123. |
29. | Stern JR, Cafasso DE, Schneider DB, et al. Totally percutaneous fenestration via the “cheese-wire” technique to facilitate endovascular aneurysm repair in chronic aortic dissection. Vasc Endovasc Surg, 2018, 52(3): 218-221. |
30. | Han T, Wu Y, Jin C, et al. Reverse “cheese wire” fenestration for abdominal aortic dissection repair: a case report and literature review. BMC Surgery, 2022, 22(1): 145. doi: 10.1186/s12893-022-01581-4. |
31. | Stern JR, Pham XD, Lee JT. Reverse cheese-wire septotomy to create a distal landing zone for thoracic endovascular aortic repair. J Endovasc Ther, 2023, 30(1): 38-44. |
32. | Baghbani-Oskouei A, Savadi S, Mesnard T, et al. Transcatheter electrosurgical septotomy technique for chronic postdissection aortic aneurysms. J Vasc Surg Cases Innov Tech, 2024, 10(2): 101402. doi: 10.1016/j.jvscit.2023.101402. |
33. | Bastianon M, Di Gregorio S, Melani C, et al. Visceral aorta electrocautery septotomy to allow branched endovascular aortic repair in ruptured chronic post-dissection thoraco-abdominal aneurysm. J Endovasc Ther, 2024: 15266028241240900. doi:10.1177/15266028241240900. |
34. | Tanenbaum MT, Figueroa AV, Lee KB, et al. Early results of transcatheter electrosurgical aortic septotomy for endovascular repair of chronic dissecting aortoiliac aneurysms. J Vasc Surg Cases Innov Tech, 2024, 10(3): 101467. doi: 10.1016/j.jvscit.2024.101467. |
35. | Gandet T, Alushi K, Westermann D, et al. “Powered Cheese Wire Technique” for septal fenestration in complex endovascular repair for chronic thoracoabdominal aortic dissection. J Endovasc Ther, 2021, 28(5): 676-681. |
36. | Bozzani A, Farè C, Arici V, et al. Aortic septotomy with scissor-technique. JTCVS Tech, 2022, 16: 14-15. |
37. | Qato K, Conway A, Northfield E, et al. Laser-assisted “Scissor” technique to facilitate thoracic endovascular aortic repair for chronic type B aortic dissection. Ann Vasc Surg, 2021, 77: 347. doi: 10.1016/j.avsg.2021.04.048. |
38. | Fukuhara S, Tchouta L, Pampati R, et al. Laser aortic septotomy during thoracic endovascular aortic repair for chronic type B aortic dissection. J Thorac Cardiovasc Surg, 2022, 164(2): 450-459. |
39. | Fukuhara S, Khaja MS, Williams DM, et al. Aortic septotomy to optimize landing zones during thoracic endovascular aortic repair for chronic type B aortic dissection. J Thorac Cardiovasc Surg, 2023, 165(5): 1776-1786. |
40. | Castro-Ferreira R, Dias PG, Sampaio SM, et al. Simplified hybrid repair with true lumen recycling for retrograde renovisceral perfusion in a complex chronic aortic dissection. J Vasc Surg Cases Innov Tech, 2018, 4(3): 226-230. |
41. | Simring D, Raja J, Morgan-Rowe L, et al. Placement of a branched stent graft into the false lumen of a chronic type B aortic dissection. J Vasc Surg, 2011, 54(6): 1784-1787. |
42. | Vaislic CD. Four-year outcomes with the multilayer flow modulator for repair of thoracoabdominal aneurysms: a follow-up report from the STRATO trial. Sang Thromb Vaiss, 2017, 29(3): 95-105. |
43. | Sultan S, Hynes N. One-year results of the multilayer flow modulator stent in the management of thoracoabdominal aortic aneurysms and type B dissections. J Endovasc Ther, 2013, 20(3): 366-377. |
44. | Lu C, Duan W, Li Z, et al. One-year results of the flowdynamics dense mesh stent for residual dissection after proximal repair of stanford type A or type B aortic dissection: a multicenter, prospective and randomized study. Int J Surg, 2024 Apr 9. doi: 10.1097/JS9.0000000000001440. Online ahead of print. |
45. | Hofferberth SC, Nixon IK, Mossop PJ. Aortic false lumen thrombosis induction by embolotherapy (AFTER) following endovascular repair of aortic dissection. J Endovasc Ther, 2012, 19(4): 538-545. |
46. | Miletic KG, Kindzelski BA, Hodges KE, et al. Impact of endovascular false lumen embolization on thoracic aortic remodeling in chronic dissection. Ann Thorac Surg, 2021, 111(2): 495-501. |
47. | Pellenc Q, Roussel A, De Blic R, et al. False lumen embolization in chronic aortic dissection promotes thoracic aortic remodeling at midterm follow-up. J Vasc Surg, 2019, 70(3): 710-717. |
48. | Rokosh RS, Chen S, Cayne N, et al. Adjunctive false lumen intervention for chronic aortic dissections is safe but offers unclear benefit. Ann Vasc Surg, 2021, 76: 10-19. |
49. | Ge Y, Zhang H, Guo W. First in man: blocking the false lumen backflow of aortic dissection after thoracic endovascular aortic repair by an off-the-shelf EndoSeal™ system. Eur Heart J, 2024 Mar 1: ehae117. doi:10.1093/eurheartj/ehae117. |
50. | Kölbel T, Lohrenz C, Kieback A, et al. Distal false lumen occlusion in aortic dissection with a homemade extra-large vascular plug: the candy-plug technique. J Endovasc Ther, 2013, 20(4): 484-489. |
51. | Rohlffs F, Tsilimparis N, Mogensen J, et al. False lumen occlusion in chronic aortic dissection: the new generation candy-plugⅡ. Ann Vasc Surg, 2019, 57: 261-265. |
52. | Bertoglio L, Bilman V, Rohlffs F, et al. Self-occluding candy-plug: implantation technique to obtain false lumen thrombosis in chronic aortic dissections. J Endovasc Ther, 2023, 30(6): 811-816. |
53. | Eleshra A, Haulon S, Bertoglio L, et al. Custom made candy plug for distal false lumen occlusion in aortic dissection: international experience. Eur J Vasc Endovasc Surg, 2023, 66(1): 50-56. |
54. | Zhou M, Liu F, Shu X, et al. Spot stenting combined with false lumen endovascular occlusive repair for post-dissection abdominal aortic aneurysm. J Endovasc Ther, 2022, 29(5): 705-710. |
55. | 原野, 周旻, 王恩慈, 等. 真腔覆膜支架点状植入联合假腔内栓塞技术治疗腔内修复术后主动脉夹层动脉瘤. 外科理论与实践, 2022, 27(5): 458-462. |
56. | Cao L, Zhang H, Guo W. First in man: sealing the distal re-entry tears of aortic dissection after thoracic endovascular aortic repair by an ENDOPATCHTM system. Eur. Heart J, 2023, 44(3): 237-237. |
57. | Ge YY, Zhang HP, Guo W. A novel endovascular double-disc implant for sealing intimal tears in aortic dissection. JACC Asia, 2023, 3(6): 937-941. |
58. | Mylonas SN, Aras T, Dorweiler B. A systematic review and an updated meta-analysis of fenestrated/branched endovascular aortic repair of chronic post-dissection thoracoabdominal aortic aneurysms. J Clin Med, 2024, 13(2): 410. doi: 10.3390/jcm13020410. |
59. | Liu J, Li Z, Feng J, et al. Total endovascular repair with parallel stent-grafts for postdissection thoracoabdominal aneurysm after prior proximal repair. J Endovasc Ther, 2019, 26(5): 668-675. |
60. | Katsargyris A, Marques De Marino P, Mufty H, et al. Early experience with the use of inner branches in endovascular repair of complex abdominal and thoraco-abdominal aortic aneurysms. Eur J Vasc Endovasc Surg, 2018, 55(5): 640-646. |
61. | Zacà S, Di Stefano L, Desantis C, et al. Total endovascular aortic replacement in post-dissecting thoraco-abdominal aortic aneurysm with a new inner branched device. Ann Vasc Surg, 2022, 78: 378. doi: 10.1016/j.avsg.2021.06.009. |
- 1. Writing Committee Members; Isselbacher EM, Preventza O, et al. 2022 ACC/AHA guideline for the diagnosis and management of aortic disease: A report of the American Heart Association/American College of Cardiology Joint Committee on Clinical Practice Guidelines. J Thorac Cardiovasc Surg, 2023, 166(5): e182-e331. doi: 10.1016/j.jtcvs.2023.04.023.
- 2. Xu H, Xiong J, Han X, et al. Computed tomography-based hemodynamic index for aortic dissection. J Thorac Cardiovasc Surg, 2021, 162(2): e165-e176. doi:10.1016/j. jtcvs. 2020. 02. 034.
- 3. Fattori R, Montgomery D, Lovato L, et al. Survival after endovascular therapy in patients with type B aortic dissection: a report from the International Registry of Acute Aortic Dissection (IRAD). JACC Cardiovasc Interv, 2013, 6(8): 876-882.
- 4. Qin YL, Deng G, Li TX, et al. Risk factors of incomplete thrombosis in the false lumen after endovascular treatment of extensive acute type B aortic dissection. J Vasc Surg, 2012, 56(5): 1232-1238.
- 5. Ge YY, Rong D, Ge XH, et al. The 301 classification: a proposed modification to the stanford type B aortic dissection classification for thoracic endovascular aortic repair prognostication. Mayo Clin Proc, 2020, 95(7): 1329-1341.
- 6. Lombardi JV, Gleason TG, Panneton JM, et al. Five-year results of the STABLEⅡ study for the endovascular treatment of complicated, acute type B aortic dissection with a composite device design. J Vasc Surg, 2022, 76(5): 1189-1197.
- 7. Wang R, Kan Y, Yang M, et al. Clinical results and aortic remodeling after endovascular treatment for complicated type B aortic dissection with the “Fabulous” stent system. Front Cardiovasc Med, 2022, 9: 817675. doi: 10.3389/fcvm.2022.817675.
- 8. Żołnierczuk M, Miśkiewicz M, Paduch J, et al. Questionable long-term results of the extended provisional extension to induce complete attachment (E-PETTICOAT) technique in the management of chronic type B aortic dissection. Ann Vasc Surg, 2023, 89: 210-215.
- 9. Mascia D, Rinaldi E, Salvati S, et al. Thoracic endovascular aortic repair with additional distal bare stents in type B aortic dissection does not prevent long-term aneurysmal degeneration. J Endovasc Ther, 2021, 28(3): 425-433.
- 10. Wamala I, Nazari-Shafti MTZ, Heck R, et al. Aortic remodelling and late outcomes following thoracic endovascular repair with a bare-metal stent distal extension among patients with complicated type-B aortic dissection. Interact Cardiovasc Thorac Surg, 2022, 35(5): ivac244. doi: 10.1093/icvts/ivac244.
- 11. Maurin A, Jacquier A, Bartoli A, et al. STABILISE (stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair) is associated with good anatomical results on the distal thoracoabdominal aorta at 2 years. J Endovasc Ther, 2024: 15266028241232923. doi: 10.1177/15266028241232923.
- 12. Bayfield NGR, Bennett A, Ritter JC. Stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair (STABILISE): A meta-analysis of early outcomes. Ann Vasc Surg, 2024, 98: 146-154.
- 13. Vecchini F, Haupert G, Baudry A, et al. Risk factors for incomplete aortic remodeling with stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair for complicated aortic dissection: results of a multicenter study. J Endovasc Ther, 2024, 31(1): 69-79.
- 14. de Beaufort HWL, Vos JA, Heijmen RH. Initial single-center experience with the knickerbocker technique during thoracic endovascular aortic repair to block retrograde false lumen flow in patients with type B aortic dissection. J Endovasc Ther, 2022: 15266028221134889. doi: 10.1177/15266028221134889.
- 15. Blitzer DN, Pereira GA, Drucker C, et al. The Caged Knickerbocker: A novel modification to targeted false lumen management in complex aortic dissection. Vasc Endovascular Surg, 2023, 57(3): 197-202.
- 16. Rohlffs F, Tsilimparis N, Panuccio G, et al. The Knickerbocker Technique: Technical aspects and single-center results of a new endovascular method for false lumen occlusion in chronic aortic dissection. J Endovasc Ther, 2023, 30(4): 609-614.
- 17. Zha B, Xu G, Zhu H, et al. Endovascular repair of type B aortic dissection with the restrictive bare stent technique: morphologic changes, technique details, and outcomes. Ther Clin Risk Manag, 2018, 14: 1993-2002.
- 18. Li X, Zhang Y, Sun Z, et al. Prevention of distal stent graft-induced new entry after endovascular repair for type B aortic dissection: A retrospective cohort study. J Thorac Cardiovasc Surg, 2024, 167(1): 28-38.
- 19. Feng J, Lu Q, Zhao Z, et al. Restrictive bare stent for prevention of stent graft-induced distal redissection after thoracic endovascular aortic repair for type B aortic dissection. J Vasc Surg, 2013, 57(2 Suppl): 44S-52S. doi: 10.1016/j.jvs.2012.06.117.
- 20. Zhao Y, Yin H, Chen Y, et al. Restrictive bare stent prevents distal stent graft-induced new entry in endovascular repair of type B aortic dissection. J Vasc Surg, 2018, 67(1): 93-103.
- 21. Kazimierczak A, Rynio P, Jędrzejczak T, et al. Expanded Petticoat technique to promote the reduction of contrasted false lumen volume in patients with chronic type B aortic dissection. J Vasc Surg, 2019, 70(6): 1782-1791.
- 22. Kazimierczak A, Jedrzejczak T, Rynio P, et al. Favorable remodeling after hybrid arch debranching and modified provisional extension to induce complete attachment technique in type A aortic dissection: A case report. Medicine, 2018, 97(37): e12409. doi: 10.1097/MD.0000000000012409.
- 23. Kazimierczak A, Rynio P, Jędrzejczak T, et al. Aortic remodeling after extended PETTICOAT technique in acute aortic dissection type Ⅲ B. Ann Vasc Surg, 2020, 66: 183-192.
- 24. Mufty H, Katsargyris A, Houthoofd S, et al. Technical note: dissection flap perforation with use of a TIPS-needle during fenestrated endografting for post-dissection thoracoabdominal aneurysms. Cardiovasc Inter Rad, 2018, 41(6): 964-967.
- 25. Correia R, Alves G, Bento R, et al. Dissection flap fenestration with a transjugular intrahepatic portosystemic shunt needle: An adjuvant technique in endovascular treatment of post-dissection thoraco-abdominal aortic aneurysms. EJVES Vasc Forum, 2021, 52: 38-40.
- 26. Tashiro J, Baqai A, Goldstein L J, et al. “Cheese wire” fenestration of a chronic aortic dissection flap for endovascular repair of a contained aneurysm rupture. J Vasc Surg, 2014, 60(2): 497-499.
- 27. Iwakoshi S, Watkins CA, Ogawa Y, et al. “Cheese Wire” fenestration of dissection intimal flap to facilitate thoracic endovascular aortic repair in chronic dissection. J Vasc Interv Radiol, 2020, 31(1): 150-154.
- 28. 杨鑫, 戴向晨, 朱杰昌, 等. Cheese wire结合开窗腔内修复术重建内脏动脉治疗胸腹主动脉夹层动脉瘤一例. 中华血管外科杂志, 2018, 3(2): 120-123.
- 29. Stern JR, Cafasso DE, Schneider DB, et al. Totally percutaneous fenestration via the “cheese-wire” technique to facilitate endovascular aneurysm repair in chronic aortic dissection. Vasc Endovasc Surg, 2018, 52(3): 218-221.
- 30. Han T, Wu Y, Jin C, et al. Reverse “cheese wire” fenestration for abdominal aortic dissection repair: a case report and literature review. BMC Surgery, 2022, 22(1): 145. doi: 10.1186/s12893-022-01581-4.
- 31. Stern JR, Pham XD, Lee JT. Reverse cheese-wire septotomy to create a distal landing zone for thoracic endovascular aortic repair. J Endovasc Ther, 2023, 30(1): 38-44.
- 32. Baghbani-Oskouei A, Savadi S, Mesnard T, et al. Transcatheter electrosurgical septotomy technique for chronic postdissection aortic aneurysms. J Vasc Surg Cases Innov Tech, 2024, 10(2): 101402. doi: 10.1016/j.jvscit.2023.101402.
- 33. Bastianon M, Di Gregorio S, Melani C, et al. Visceral aorta electrocautery septotomy to allow branched endovascular aortic repair in ruptured chronic post-dissection thoraco-abdominal aneurysm. J Endovasc Ther, 2024: 15266028241240900. doi:10.1177/15266028241240900.
- 34. Tanenbaum MT, Figueroa AV, Lee KB, et al. Early results of transcatheter electrosurgical aortic septotomy for endovascular repair of chronic dissecting aortoiliac aneurysms. J Vasc Surg Cases Innov Tech, 2024, 10(3): 101467. doi: 10.1016/j.jvscit.2024.101467.
- 35. Gandet T, Alushi K, Westermann D, et al. “Powered Cheese Wire Technique” for septal fenestration in complex endovascular repair for chronic thoracoabdominal aortic dissection. J Endovasc Ther, 2021, 28(5): 676-681.
- 36. Bozzani A, Farè C, Arici V, et al. Aortic septotomy with scissor-technique. JTCVS Tech, 2022, 16: 14-15.
- 37. Qato K, Conway A, Northfield E, et al. Laser-assisted “Scissor” technique to facilitate thoracic endovascular aortic repair for chronic type B aortic dissection. Ann Vasc Surg, 2021, 77: 347. doi: 10.1016/j.avsg.2021.04.048.
- 38. Fukuhara S, Tchouta L, Pampati R, et al. Laser aortic septotomy during thoracic endovascular aortic repair for chronic type B aortic dissection. J Thorac Cardiovasc Surg, 2022, 164(2): 450-459.
- 39. Fukuhara S, Khaja MS, Williams DM, et al. Aortic septotomy to optimize landing zones during thoracic endovascular aortic repair for chronic type B aortic dissection. J Thorac Cardiovasc Surg, 2023, 165(5): 1776-1786.
- 40. Castro-Ferreira R, Dias PG, Sampaio SM, et al. Simplified hybrid repair with true lumen recycling for retrograde renovisceral perfusion in a complex chronic aortic dissection. J Vasc Surg Cases Innov Tech, 2018, 4(3): 226-230.
- 41. Simring D, Raja J, Morgan-Rowe L, et al. Placement of a branched stent graft into the false lumen of a chronic type B aortic dissection. J Vasc Surg, 2011, 54(6): 1784-1787.
- 42. Vaislic CD. Four-year outcomes with the multilayer flow modulator for repair of thoracoabdominal aneurysms: a follow-up report from the STRATO trial. Sang Thromb Vaiss, 2017, 29(3): 95-105.
- 43. Sultan S, Hynes N. One-year results of the multilayer flow modulator stent in the management of thoracoabdominal aortic aneurysms and type B dissections. J Endovasc Ther, 2013, 20(3): 366-377.
- 44. Lu C, Duan W, Li Z, et al. One-year results of the flowdynamics dense mesh stent for residual dissection after proximal repair of stanford type A or type B aortic dissection: a multicenter, prospective and randomized study. Int J Surg, 2024 Apr 9. doi: 10.1097/JS9.0000000000001440. Online ahead of print.
- 45. Hofferberth SC, Nixon IK, Mossop PJ. Aortic false lumen thrombosis induction by embolotherapy (AFTER) following endovascular repair of aortic dissection. J Endovasc Ther, 2012, 19(4): 538-545.
- 46. Miletic KG, Kindzelski BA, Hodges KE, et al. Impact of endovascular false lumen embolization on thoracic aortic remodeling in chronic dissection. Ann Thorac Surg, 2021, 111(2): 495-501.
- 47. Pellenc Q, Roussel A, De Blic R, et al. False lumen embolization in chronic aortic dissection promotes thoracic aortic remodeling at midterm follow-up. J Vasc Surg, 2019, 70(3): 710-717.
- 48. Rokosh RS, Chen S, Cayne N, et al. Adjunctive false lumen intervention for chronic aortic dissections is safe but offers unclear benefit. Ann Vasc Surg, 2021, 76: 10-19.
- 49. Ge Y, Zhang H, Guo W. First in man: blocking the false lumen backflow of aortic dissection after thoracic endovascular aortic repair by an off-the-shelf EndoSeal™ system. Eur Heart J, 2024 Mar 1: ehae117. doi:10.1093/eurheartj/ehae117.
- 50. Kölbel T, Lohrenz C, Kieback A, et al. Distal false lumen occlusion in aortic dissection with a homemade extra-large vascular plug: the candy-plug technique. J Endovasc Ther, 2013, 20(4): 484-489.
- 51. Rohlffs F, Tsilimparis N, Mogensen J, et al. False lumen occlusion in chronic aortic dissection: the new generation candy-plugⅡ. Ann Vasc Surg, 2019, 57: 261-265.
- 52. Bertoglio L, Bilman V, Rohlffs F, et al. Self-occluding candy-plug: implantation technique to obtain false lumen thrombosis in chronic aortic dissections. J Endovasc Ther, 2023, 30(6): 811-816.
- 53. Eleshra A, Haulon S, Bertoglio L, et al. Custom made candy plug for distal false lumen occlusion in aortic dissection: international experience. Eur J Vasc Endovasc Surg, 2023, 66(1): 50-56.
- 54. Zhou M, Liu F, Shu X, et al. Spot stenting combined with false lumen endovascular occlusive repair for post-dissection abdominal aortic aneurysm. J Endovasc Ther, 2022, 29(5): 705-710.
- 55. 原野, 周旻, 王恩慈, 等. 真腔覆膜支架点状植入联合假腔内栓塞技术治疗腔内修复术后主动脉夹层动脉瘤. 外科理论与实践, 2022, 27(5): 458-462.
- 56. Cao L, Zhang H, Guo W. First in man: sealing the distal re-entry tears of aortic dissection after thoracic endovascular aortic repair by an ENDOPATCHTM system. Eur. Heart J, 2023, 44(3): 237-237.
- 57. Ge YY, Zhang HP, Guo W. A novel endovascular double-disc implant for sealing intimal tears in aortic dissection. JACC Asia, 2023, 3(6): 937-941.
- 58. Mylonas SN, Aras T, Dorweiler B. A systematic review and an updated meta-analysis of fenestrated/branched endovascular aortic repair of chronic post-dissection thoracoabdominal aortic aneurysms. J Clin Med, 2024, 13(2): 410. doi: 10.3390/jcm13020410.
- 59. Liu J, Li Z, Feng J, et al. Total endovascular repair with parallel stent-grafts for postdissection thoracoabdominal aneurysm after prior proximal repair. J Endovasc Ther, 2019, 26(5): 668-675.
- 60. Katsargyris A, Marques De Marino P, Mufty H, et al. Early experience with the use of inner branches in endovascular repair of complex abdominal and thoraco-abdominal aortic aneurysms. Eur J Vasc Endovasc Surg, 2018, 55(5): 640-646.
- 61. Zacà S, Di Stefano L, Desantis C, et al. Total endovascular aortic replacement in post-dissecting thoraco-abdominal aortic aneurysm with a new inner branched device. Ann Vasc Surg, 2022, 78: 378. doi: 10.1016/j.avsg.2021.06.009.