Objective To evaluate the value of 99Tcm-Octreotide somatostatin receptor and 99Tcm-MIBI imaging in the detection of breast cancer.
Methods 99Tcm-Octreotide and 99Tcm-MIBI imaging were performed in 26 patients with breast masses before operation. The scintigraphy results were analysed compared with pathologic study.
Results The sensitivity, specificity and accuracy of 99Tcm-Octreotide scintigraphy for breast cancer were 94.4%, 87.5% and 92.3% respectively and those of 99Tcm-MIBI were 88.9%, 75.0% and 84.6% respectively. Significant difference was found between 99Tcm-Octreotide and 99Tcm-MIBI in both of specificity and accuracy (P<0.05 and P<0.01). The sensitivity, specificity and accuracy of 99Tcm-Octreotide scintigraphy in the detection of axillary lymph node involvement were 66.7%, 92.9% and 80.8% respectively. Those of 99Tcm-MIBI were 58.3%, 85.7% and 73.1% respectively. The specificity showed significant difference between 99Tcm-Octreotide and 99Tcm-MIBI (P<0.01).
Conclusion 99Tcm-Octreotide somatostatin receptor imaging may be superior to 99Tcm-MIBI in the detection of primary breast cancer and axillary lymph node involvement, and 99Tcm-Octreotide scintigraphy before operation is helpful in working out operative modality for patients.
Citation:
DENG Nianying,ZHANG Jinshan,XIAN Youqing. Clinical Application of 99Tcm-Octreotide and 99Tcm-MIBI Imaging in the Diagnosis of Breast Cancer. CHINESE JOURNAL OF BASES AND CLINICS IN GENERAL SURGERY, 2004, 11(1): 17-19. doi:
Copy
Copyright © the editorial department of CHINESE JOURNAL OF BASES AND CLINICS IN GENERAL SURGERY of West China Medical Publisher. All rights reserved
1. |
Mekhmandarov S, Sandbank J, Cohen M, et al. Technetium-99m-MIBI scintimammography in palpable and nonpalpable breast lesions [J]. J Nucl Med, 1998; 39(1)∶86.
|
2. |
屈翔, 王宇, 陈道荫, 等. 99m锝腋窝扫描在乳腺癌手术方案中的临床价值 [J]. 中华外科杂志, 1999; 37(1)∶41.
|
3. |
鸿文. 99Tcm标记生长抑素类似物作为受体显像及特异性研究 [J]. 国外医学放射核医学分册, 1998; 22(4)∶158.
|
4. |
Cuntz MC, Levine EA, O’Dorisio TM, et al. Intraoperative gamma detection of 125I-lanreotide in women with primary breast cancer [J]. Ann Surg Oncol, 1999; 6(4)∶367.
|
5. |
Skanbcrg J, Ahlman H, Bcnjcgard SA, et al. Indiu-111-Octrcotidc scintigraply intraopcrativc gamma-delectorlocalisation and somatostatin receptor expression in primary haman breast cancer [J]. Breast Cancer Res Treat, 2002; 74(2)∶101.
|
6. |
Monlani MC,Levine EA,Watson JC,et al. Intraoperative gamma detection 125I-lanreotide in women with primary breast carcinoma [J]. Abstract Regul Pept,1996; 64∶1.
|
7. |
邓念英, 方云光, 伍尚标, 等. 生长抑素受体在原发性乳腺癌中的表达及其意义 [J]. 中华实验外科杂志, 2003; 20(2)∶172.
|
8. |
邓念英, 张金山, 伍尚标. 生长抑素受体显像在乳腺癌诊断中应用 [J]. 中国实用外科杂志, 2003; 23(4)∶237.
|
- 1. Mekhmandarov S, Sandbank J, Cohen M, et al. Technetium-99m-MIBI scintimammography in palpable and nonpalpable breast lesions [J]. J Nucl Med, 1998; 39(1)∶86.
- 2. 屈翔, 王宇, 陈道荫, 等. 99m锝腋窝扫描在乳腺癌手术方案中的临床价值 [J]. 中华外科杂志, 1999; 37(1)∶41.
- 3. 鸿文. 99Tcm标记生长抑素类似物作为受体显像及特异性研究 [J]. 国外医学放射核医学分册, 1998; 22(4)∶158.
- 4. Cuntz MC, Levine EA, O’Dorisio TM, et al. Intraoperative gamma detection of 125I-lanreotide in women with primary breast cancer [J]. Ann Surg Oncol, 1999; 6(4)∶367.
- 5. Skanbcrg J, Ahlman H, Bcnjcgard SA, et al. Indiu-111-Octrcotidc scintigraply intraopcrativc gamma-delectorlocalisation and somatostatin receptor expression in primary haman breast cancer [J]. Breast Cancer Res Treat, 2002; 74(2)∶101.
- 6. Monlani MC,Levine EA,Watson JC,et al. Intraoperative gamma detection 125I-lanreotide in women with primary breast carcinoma [J]. Abstract Regul Pept,1996; 64∶1.
- 7. 邓念英, 方云光, 伍尚标, 等. 生长抑素受体在原发性乳腺癌中的表达及其意义 [J]. 中华实验外科杂志, 2003; 20(2)∶172.
- 8. 邓念英, 张金山, 伍尚标. 生长抑素受体显像在乳腺癌诊断中应用 [J]. 中国实用外科杂志, 2003; 23(4)∶237.