Abstract: Objective To estimate the effectiveness and safety of intra-aortic balloon pump (IABP)in the patients with mild or mild to moderate aortic regurgitation. Methods A total of 15 patients with mild or mild to moderate aortic regurgitation and low left ventricular ejection fraction (LVEF< 40.00%) including 11 males and 4 females, who underwent IABP application after cardiac surgery between September 2006 and January 2011, were included in this study. Their age ranged from 50 to 74 years with an average age of 63.60 years. There were 9 patients with mild aortic regurgitation and 6 patients with mild to moderate aortic regurgitation, all with LVEF < 40.00%. IABP catheters were inserted before operation and IABP worked after heart the recovery of heart beat. Mean aortic pressure (MAP), cardiac index (CI), systemic vascular resistance index (SVRI), pulmonary vascular resistance index (PVRI), LVEF , and aortic regurgitation volume before the use of IABP and after stopping use of it were compared. Results The total mortality was zero. The patients’ CI significantly improved from 1.99±0.23 L/(min.m2) to 3.30±0.29 L/(min.m2) after IABP (t =48.30,P=0.00). Their LVEFs were significantly improved after use of IABP (37.20%±1.37% versus 42.60%±2.87%, t =11.34,P=0.00). Their SVRI improved significantly (2 347.00±190.00 dyn·s/(cm5·m2) versus 2 128.00±204.00 dyn·s/(cm5 · m2),t=20.60, P=0.00)after use of IABP. However, their aortic regurgitation volume were not significantly increased(χ2=0.60, P=0.44). Conclusion Application of IABP in patients with mild or mild to moderate aortic regurgitation and low LVEF can obtain good circulation support after operation without increasing their aortic regurgitation.
Citation: LIU Hao,DING Fangbao,HUANG Jianbing,et al .. Application of Intra-aortic Balloon Pump in Patients with Mild or Mild to Moderate Aortic Regurgitation. Chinese Journal of Clinical Thoracic and Cardiovascular Surgery, 2012, 19(1): 48-51. doi: Copy