• Department of Cardiac Surgery, Zhongshan Hospital, Fudan University, Shanghai 200032, P. R. China;
Export PDF Favorites Scan Get Citation

Objective To evaluate the efficacy of Radiofrequency (RF) modified maze procedure combined with open-heart surgery for atrial fibrillation (AF). Methods From January 2003 to October 2004, 66 patients underwent the RF modified maze Ⅲ procedure for AF combined with open-heart surgery. The preoperative and postoperative indexes of electrocardiogram and echoeardiogram were compared through retrospective analysis and follow-up. Postoperative cardiac function and thromboembolie events were evaluated through telephone and mail. Results The time needed for RF modified maze Ⅲ was 18.61±3.56 min. There were no hospital deaths and the complications was 15.15%(10/66). Follow-up duration was 14.25±6.47 months with 95.45%(63/66) completion. At the lastest follow-up, the rate of freedom from AF was 80.95% (51/63)and the rate of restoration to sinus rhythm was 74.60%(47/63). No thromboembolic events was seen. 77.78%(49/63) of patients were in NYHA class Ⅰ. Significant decrease was seen in both left atrial dimension (LAD) and left ventricular dimension (LVD)(P〈0.01) more than 6 months after operation. Conclusion RF modified maze Ⅲ procedure as an adjunctive procedure is safe, time-sparing and effective in eliminating AF.

Citation: WANG Shaohua,WANG Chunsheng. Efficacy of Radiofrequency Modified Maze Procedure Combined with Open-heart Surgery for Atrial Fibrillation. Chinese Journal of Clinical Thoracic and Cardiovascular Surgery, 2006, 13(5): 302-306. doi: Copy