Objective To evaluate the function of the reconstructed thumbs and the donor feet after thumb reconstructions with modified wrap-around flap. Methods A total of 65 patients who accepted thumb reconstruction with the modified wrap-around flap between January 2003 and October 2007 were followed up, including 54 males and 11 females with an average age of 33 years (range 15-46 years). There were 12 cases of skin degloving injury and late class I B defect, 44 cases of class II defect and 9 cases of class III A defect. The reconstructed thumbs and donor feet were examined and
evaluated. Foot function index-verbal rating scales (FFI-5pt), American Orthopaedic Foot and Ankle Society (AOFAS) for
hallux metatarsophalangeal-interphalangeal score, gait analysis and dynamic pedobarography were conducted to 20 patients who were followed up recently. Results Sixty-five patients were followed up 6-60 months with an average of 22 months. The reconstructed thumbs had aesthetic appearance and satisfactory range of motion. The two-point discrimination was (9.7 ± 2.8) mm, showing statistically significant difference (P lt; 0.05) when compared with that of the contralateral normal thumb [(4.2 ± 1.1) mm]. Full or most length of the donor toes were preserved in 63 patients. The width of remaining plantar strip skin that covered the plantar weight-bearing area was (24.5 ± 3.7) mm, and its two-point discrimination was (9.0 ± 2.6) mm; showing no statistically significant difference (P gt; 0.05) when compared with that of contralateral normal one [(8.1 ± 1.9) mm]. Of the 20 patients who were followed up recently, the evaluation of the FFI-5pt score showed that the pain scale score was 5.6 ± 4.5, the disabil ity scale score was 1.2 ± 2.7, and the FFI-5pt total scale score was 3.2 ± 2.9. The results of AOFAS cl inical rating scale showed that the pain scale score was 34.0 ± 5.0, the function scale score was 38.7 ± 4.2, the al igment scale score was 15.0 ± 0, and the total AOFAS scale score was 87.7 ± 7.4. There was no statistically significant difference (P gt; 0.05) in the durations of subphases of the gait cycle between the donor foot and the contralateral normal foot, and in the peak force and force-time integral of the two whole foot. The peak force of the donor toe was significantly smaller than that of the contralateral normal toe (P lt; 0.05), but there was no significant difference in the peak pressure (P gt; 0.05); and there were no significant differences in the peak forces
and peak pressures of other six anatomical sites of the two feet (P gt; 0.05). Conclusion Using the modified wrap-around flap for thumb reconstruction, aesthetic and functional thumbs can be obtained, and most of the function of the donor feet can be preserved.
Citation: ZHANG Lishan,PAN Yongwei,TIAN Guanglei,TIAN Wen,GUO Xianfeng,WANG Manyi.. THUMB RECONSTRUCTION WITH MODIFIED FREE WRAP-AROUND FLAP. Chinese Journal of Reparative and Reconstructive Surgery, 2010, 24(3): 309-314. doi: Copy