Objective To compare the clinical outcomes and safety of minimally invasive and routine mitral valve repair or replacement for patients with single mitral valve disease. Methods We retrospectively analyzed the clinical data of 67 patients with single mitral valve disease (without aortic valve and tricuspid valve lesion or other heart diseases including atrial septal defect) who underwent mitral valve repair or replacement in the First Affiliated Hospital of China Medical University between January and July 2011. The patients were divided into two groups according to different surgical approaches:the minimally invasive surgery group (n=29,8 males and 21 females,age 51.4±9.4 years) underwent minimally invasive mitral valve repair or replacement via right mini-thoractomy;and the routine surgery group (n=38,11 males and 27 females,age 53.6±11.9 years) underwent mitral valve repair or replacement via middle sternotomy. In the minimally invasive surgery group,9 patients underwent mitral valve repair while the other 20 patients underwent mitral valve replacement. And no patient underwent transition to routine operation. In the routine surgery group,15 patients underwent mitral valve repair and 23 patients underwent mitral valve replacement. Clinical outcomes and safety of the operations were compared between the two groups. Results There was no statistical difference in operation time between the two groups (207.9±18.1 min versus 198.4±27.5 min,P=0.076). The amount of postoperative drainage (126.7±34.5 ml versus 435.6±87.2 ml,P=0.000) and blood transfusion (red blood cell 1.4±0.8 U versus 2.3±1.1 U,P=0.000;blood plasma 164.3±50.4 ml versus 405.6±68.9 ml,P=0.000) of the minimally invasive surgery group were significantly lower than those of the routine surgery group. The cardiopulmonary bypass time (81.7±23.9 min versus 58.7±13.6 min,P=0.000) and aortic-clamping time (51.6±12.7 min versus 38.4±11.7 min,P=0.000) of the minimally invasive surgery group were significantly longer than those of the routine surgery group. The length of ICU stay (22.5±3.6 h versus 31.7±8.5 h,P=0.000),mechanical ventilation (7.4±3.2 h versus 11.2±5.1 h,P=0.000) and postoperative hospitalization (7.1±1.6 d versus 13.5±2.4 d,P=0.000) of the minimally invasive surgery group were significantly shorter than those of the routine surgery group. There was no statistical difference in postoperative complications between the two groups. Minimally invasive surgery group patients were followed up for 5.3±2.4 months with a follow-up rate of 72.4%(21/29). Routine surgery group patients were followed up for 5.5±3.8 months with a follow-up rate of 71.0%(27/38). There was no significant complication during follow-up in both two groups. Conclusion Minimally invasive mitral valve operation via right mini-thoracotomy is effective and safe with a good cosmetic result. Compared with routine operation,patients undergoing minimally invasive operation recover better and faster.
Objective To summarize surgical techniques,advantages and clinical outcomes of mitral valvuloplasty for anterior mitral leaflet prolapse with looped artificial chordae. Methods Clinical data of 13 patients with anteriormitral leaflet prolapse and severe mitral regurgitation (MR) who underwent mitral valvuloplasty with looped artificial chordaefrom January 2009 to December 2011 in Beijing Anzhen Hospital were retrospectively analyzed. There were 8 male and 5 female patients with their age of 21-61 (39.5±12.9) years. There were 10 patients with anterior mitral leaflet chordal rupture and 3 patients with anterior mitral leaflet elongation. Preoperative left ventricular end-diastolic diameter (LVEDD) was 52-65 (58.3±1.7) mm,and left ventricular ejection fraction (LVEF) was 53%-65% (58.8%±2.8%). All the patients underwent mitral valvuloplasty. We measured the neighboring normal chordae with a caliper for reference and constructed the artificial chordal loops on the caliper with expended polytetrafluoroethylene(ePTFE) CV4 Gore-Tex suture lines. Three to five loops were made and fixed to the papillary muscle with a Gore-Tex suture line and the free edge of the prolapsedanterior mitral leaflet with another Gore-Tex suture line,with the intervals between the loops of 5 mm. Left ventricular watertesting was performed to evaluate MR status,annuloplasty ring implantation or “edge to edge” technique was used if nece-ssary,and left ventricular water testing was performed again to confirm satisfactory closure of the mitral valve. Patientsreceived re-warming on cardiopulmonary bypass and the heart incision was closed. The effect of mitral annuloplasty was alsoassessed by transesophageal echocardiography (TEE) after heart rebeating. Warfarin anticoagulation was routinely used for 3 months after discharge. Results There was no perioperative death in this group. Twelve patients received satisfactory outcomes after 1-stage mitral valvuloplasty with looped artificial chordae and annuloplasty ring implantation. One patient didn’t receive satisfactory outcomes in the left ventricular water testing after mitral valvuloplasty with looped artificial chordae,but satisfactory outcome was achieve after “edge to edge” technique was used,and annuloplasty ring was not used for this patient. Postoperative echocardiography showed trivial to mild MR in all the patients,their LVEDD was significantly reducedthan preoperative LVEDD (47.5±2.1 mm vs. 58.3±1.7 mm,P<0.05),and there was no statistical difference between postoperative and preoperative LVEF(58.5%±2.6% vs. 58.8%±2.8%,P>0.05). All the patients were followed up for 3-36 (19.5±3.7) months. Echocardiography showed mild MR in 4 patients and none or trivial MR in 9 patients during follow-up.Conclusion Mitral valvuloplasty with looped artificial chordae is an effective surgical technique for the treatment of anterior mitral leaflet prolapse with satisfactory clinical outcomes,and this technique is also easy to perform.
Objective To analyze early and midterm outcomes and summarize clinical experience of mitral valve repair with artificial chordae for degenerative mitral regurgitation (MR). Methods Clinical data of 78 patients with degenerative MR who underwent mitral valve repair with Gore-Tex artificial chordae from October 2008 to December 2011 in General Hospita1 of Shenyang Military Command were retrospectively analyzed. There were 47 male patients and 31female patients with their age of 52.7±9.6 years,who all had degenerative MR. Operation techniques included simple GoreTex artificial chordae replacement in 15 patients,artificial chordae replacement plus quadrangular resection of the posterior leaflet in 58 patients,artificial chordae replacement plus quadrangular resection of the posterior leaflet and Sliding technique in 5 patients. One to three (2.15±1.05) Gore-Tex artificial chordae were used for each patient,and annuloplasty ring was used for all the patients. Thirty-nine patients underwent concomitant tricuspid valvuloplasty. Intraoperative transesophagealechocardiography showed none obvious MR in 62 patients,trivial MR in 13 patients and mild MR in 3 patients. All thepatients were followed up after discharge. Echocardiography was used to evaluate heart function and MR degree duringfollow-up. Results There was no in-hospital death in this group. Postoperative complications included sinus bradycardiain 5 patients,supraventricular tachycardia in 8 patients,late cardiac tamponade in 1 patient,and permanent pacemakerimplantation in 1 patient. Seventy patients were followed up for 1-2 years with the follow-up rate of 89.74% (70/78). Duringfollow-up,1 patient died of cerebral embolism 13 months after discharge,and all the other patients remained alive. There were 60 patients with NYHA classⅠand 9 patients with NYHA classⅡ. Echocardiography at 1 year after dischargeshowed that left atrial diameter,left ventricular end-diastolic diameter,left ventricular end-systolic diameter,and pulmonary artery systolic pressure were significantly smaller or lower than preoperative values (P<0.05),left ventricular ejection fraction (68.00%±7.00% vs. 55.00%±6.00%) and cardiac output were significantly higher than preoperative values(P<0.05),and MR degree (ratio of regurgitation beam area and left atrial area) was significantly reduced compared with preoperative MR degree (3.45%±5.56% vs. 39.55%±9.86%,P<0.05). No artificial chordae rupture was found. There were47 patients without MR and 22 patients with trivial MR during follow-up. Conclusion Gore-Tex artificial chordae replacement is a safe and effective surgical technique for the treatment of degenerative MR.