  • PRELIMINARY STUDY ON EFFECT OF FEMORAL TUNNEL ANGLE ON FEMORAL TUNNEL AFTER ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION IN RABBITS

    ObjectiveTo investigate the effect of the femoral tunnel angle on the femoral tunnel after anterior cruciate ligament (ACL) reconstruction in rabbits. MethodsFifty-four healthy 4-5 months old rabbits (weighing, 1.8-2.3 kg, male or female) were randomly divided into 3 groups (n=18). The ACL reconstruction models of the right knee were established in 3 experimental groups using its Achilles tendons, and the left knee served as the control group. On the coronal position, the angle between the femoral tunnel and the femoral shaft axis was 30°, 45°, and 60°. The level of tumor necrosis factor α (TNF-α) in the synovial fluid at 1, 2, and 4 weeks, the maximum load of the ligament and the rate of bone tunnel enlargement at 4, 8, and 12 weeks were detected. ResultsThe level of TNF-α significantly increased, and the maximum load of the ligament significantly decreased in the 3 experimental groups when compared with ones in the control group (P<0.05), but no significant difference was found among 3 experimental groups (P>0.05). The bone tunnel enlargement was observed in 3 experimental groups at each time point and reached the peak at 4 weeks, but no significant difference was shown among 3 groups (P>0.05). ConclusionThe 30-60° angle between the femoral tunnel and the femoral shaft axis in the coronal position has no significant effect on the femoral tunnel enlargement after ACL reconstruction in rabbits.

    Release date:2016-08-25 10:18 Export PDF Favorites Scan
  • EFFECTIVENESS OF COMPUTER-ASSISTED PREOPERATIVE PLANNING SYSTEM IN ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION

    Objective To evaluate the feasibility and effectiveness of computer-assisted preoperative planning system—ACL Detector in anterior cruciate ligament (ACL) reconstruction. Methods Between March 2009 and January 2012, 80 patients with ACL rupture received arthroscopic ACL single-bundle reconstruction with autologous hamstring tendon transplantation. Before operation, the preoperative planning was done by computer-assisted preoperative planning system—ACL Detector (trial group, n=40) or by conventional method (control group, n=40). There was no significant difference in gender, age, disease duration, injury cause, preoperative Lysholm score, and preoperative International Knee Documentation Committee (IKDC) score between 2 groups (P gt; 0.05). After operation, the effectiveness was evaluated by Lachman test, pivot shift test, Lysholm score, and IKDC score; the digital three-dimensinal model of knee was reconstructed, and the impingement rate of ACL graft was measured. Results All incisions healed by first intention, and no complication was found. The patients were followed up 18-25 months (mean, 20 months) in trial group and 18-24 months (mean, 21 months) in control group. The Lysholm score and IKDC score were significantly increased at 18 months after operation when compared with preoperative scores (P lt; 0.05), but no significant difference was found between 2 groups (P gt; 0.05). The results of Lachman test and pivot shift test at 18 months after operation were significantly better than those before operation in 2 groups (P lt; 0.05), but no significant difference between 2 groups after operation (P gt; 0.05). MRI showed that impingement was observed in 1 case of trial group (2.50%) and in 8 cases of control group (20.00%), showing significant difference (χ2=4.51, P=0.03). Conclusion The computer-assisted preoperative planning system—ACL Detector could be successfully applied to ACL reconstruction. It has the same improvement in knee functional score as conventional surgery, but it is better than conventional surgery in reducing the impingement incidence.

    Release date:2016-08-31 10:53 Export PDF Favorites Scan
  • SHORT-TERM EFFECTIVENESS OF ARTHROSCOPIC SINGLE-BUNDLE RECONSTRUCTION OF ANTERIOR CRUCIATE LIGAMENT BEING CENTERED WITHIN NATIVE LIGAMENT’S TIBIAL AND FEMORAL INSERTIONS

    Objective To evaluate the short-term effectiveness of arthroscopic single-bundle reconstruction of anterior cruciate ligament (ACL) being centered within the native ligament’s tibial and femoral insertions with independent drilling of tibial and femoral tunnels. Methods Between September 2008 and September 2010, 33 patients with chronic ACL ruptures underwent arthroscopic reconstruction with four-stranded hamstring tendons in single-bundle. There were 19 males and 14 females, aged 22-33 years (mean, 26.4 years). Injuries were caused by traffic accident in 15 cases, by falling in 13 cases, and by sports in 5 cases. The location was the left knee in 20 cases and the right knee in 13 cases. The average time from injury to surgery was 6 months (range, 2-20 months). ACL reconstruction could be optimized when single-bundle grafts were centered within the native ligament’s tibial and femoral insertions with independent drilling of tibial and femoral tunnels. KT-1000 test, Lachman test, and pivot-shift test were used to evaluate the knee stability, and the International Knee Documentation Committee (IKDC) and Lysholm scores to assess the knee function. Results Primary healing of incision was obtained in all patients, who had no complications of intra-articular infection, deep venous thrombosis of the lower extremity, and injury of blood vessels and nerves. All the patients were followed up 18.6 months on average (range, 13-24 months). At 1 year after operation, the results of Lachman test were negative in 31 cases and I degree positive in 2 cases, showing significant difference when compared with preoperative results (I degree positive in 4, II degree positive in 26, and III degree positive in 3) (Z= — 5.42, P=0.00). The results of pivot-shift test were negative in 31 cases, I degree positive in 2 cases, showing significant difference when compared with preoperative results (I degree positive in 15 and II degree positive in 18) (Z= — 5.17, P=0.00). The KT-1000 results of examination (134 N) showed that the side difference of anterior laxity was (1.2 ± 0.7) mm at 25° flexion and (0.8 ± 0.6) mm at 70° flexion, showing significant differences when compared with preoperative ones [(7.8 ± 2.1) mm and (5.0 ± 1.8) mm] (t=16.19, P=0.00; t=13.28, P=0.00). The IKDC score was significantly increased from 39.6 ± 4.5 at preoperation to 95.1 ± 1.6 at postoperation (t= — 78.88, P=0.00), and Lysholm score was significantly increased from 48.3 ± 3.6 at preoperation to 92.0 ± 2.5 at postoperation (t= — 42.00, P=0.00). Conclusion It is a reliable procedure to restore the stability of the knee that arthroscopic single-bundle reconstruction of ACL is centered within the native ligament’s tibial and femoral insertions with independent drilling of tibial and femoral tunnels.

    Release date:2016-08-31 04:05 Export PDF Favorites Scan
  • SURGICAL TREATMENT OF POSTEROMEDIAL CORNER INJURY COMBINED WITH CRUCIATE LIGAMENT RUPTURE OF KNEE

    Objective To investigate the methods and effectiveness of surgical treatment for posteromedial corner (PMC) injury combined with anterior cruciate ligament (ACL) and posterior cruciate ligament (PCL) ruptures. Methods Between February 2009 and February 2012, 15 patients (15 knees) with PMC injury combined with ACL and PCL ruptures underwent PMC repair with suture anchor and ACL and PCL reconstruction. There were 7 males and 8 females with an average age of 39 years (range, 15-59 years). The causes of injury were traffic accident injury in 6 cases, sport injury in 7 cases, and sprain injury in 2 cases. The disease duration was 3-15 days with an average of 7 days. All patients presented positive results of anterior drawer test, posterior drawer test and valgus stress test, and dysfunction of knee joint. Of 15 cases, 3 had ACL and PCL ruptures, 5 had ACL rupture, 3 had ACL injury at the attachment point of the condyles crest, and 4 had PCL rupture; 9 had PMC tear at the femur insertion, 5 had PMC tear at the tibia insertion, and 1 had PMC tear in the body area. Results All incisions healed by first intention with no complication of infection or stiffness of knee. All cases were followed up 18.4 months on average (range, 10-36 months). At last follow-up, 14 cases had normal knee flexion and extension ranges, but 1 case had 10° limitation of the knee extension. Except 1 case which had weakly positive valgus stress test, the other patients showed negative results of anterior drawer test, posterior drawer test, and valgus stress test. Based on the improved Lysholm classification standard, the results were excellent in 8 cases, good in 5 cases, and fair in 2 cases; the excellent and good rate was 86.7%. Conclusion Early repair of the PMC and reasonable reconstruction of cruciate ligament can effectively restore the knee stability for patients with PMC injury combined with ACL and PCL ruptures.

    Release date:2016-08-31 04:07 Export PDF Favorites Scan
  • ARTHROSCOPICALLY ASSISTED TREATMENT OF ACUTE TIBIAL INSERTION AVULSION FRACTURE OF POSTERIOR CRUCIATE LIGAMENT VIA POSTEROMEDIAL INCISION

    Objective To investigate the effectiveness of arthroscopically assisted treatment of acute tibial insertion avulsion fracture of the posterior cruciate ligament (PCL) via posteromedial incision. Methods Between January 2010 and January 2012, 22 patients with acute tibial insertion avulsion of the PCL underwent arthroscopic reduction and fixation via posteromedial incision. There were 14 males and 8 females with an average age of 32 years (range, 18-48 years). The injury causes included traffic accident injury in 14 cases, sport injury in 4 cases, and falling injury in 4 cases. The disease duration ranged from 7 to 16 days (mean, 10 days). Of 22 patient, 14 had simple PCL injury, 6 had PCL injury with meniscus injury, and 2 with cartilage injury. The results of posterior drawer test were positive in all patients. The preoperative Lysholm score was 51.1 ± 3.4. Results All incisions healed by first intention without infection, deep venous thrombosis of lower limbs, or vessel and nerve injuries. All patients were followed up 12-24 months (mean, 18.4 months). X-ray films showed that all fractures healed with the healing time of 2-4 months (mean, 3 months). The Lysholm score was improved to 96.0 ± 2.2 at 6 months after operation, showing significant difference when compared with preoperative score (t=43.020, P=0.000). Conclusion Arthroscopically assisted treatment of acute tibial insertion avulsion fracture of the PCL via posteromedial incision is a safe, easy, and effective method.

    Release date:2016-08-31 04:07 Export PDF Favorites Scan
  • EFFECTIVENESS OF ARTHROSCOPIC SINGLE-BUNDLE POSTERIOR CRUCIATE LIGAMENT RECONSTRUCTION WITH REMNANT PRESERVATION AND QUADRUPLED HAMSTRING TENDONS

    Objective To investigate the effectiveness of posterior cruciate ligament (PCL) reconstruction with remnant preservation and autogenous quadrupled hamstring tendons under arthroscopy. Methods Between October 2007 and August 2012, 32 patients with PCL rupture were treated and followed up for more than 1 year. There were 24 males and 8 females, aged 20-53 years (mean, 35.6 years). The causes of injury included traffic accident injury in 21 cases, sports injury in 8 cases, and falling injury from height in 3 cases. The disease duration ranged 1 week to 2 years (median, 6.3 weeks). Nine patients had simple PCL rupture, 23 patients complicated by ligament injury, including 10 cases of anterior cruciate ligament rupture, 11 cases of posterolateral corner injury, and 2 cases of posteromedial corner injury. Preoperative Lysholm score was 53.8 ± 7.1. According to the International Knee Documentation Committee (IKDC) rating criteria, 10 cases were classified as grade C and 22 cases as grade D. PCL was reconstructed with autogenous quadrupled hamstring tendons, the tendons were fixed with EndoButton at the femoral side and with interference screw at the tibial side; floats of stump were cleaned up, and the structural stability and continuity ligament remnants were preserved. Results Primary healing was obtained in all incisions; no early complication occurred after operation. Thirty-two patients were followed up 23.4 months on average (range, 12-36 months). All patients had no symptom of knee instability; the results of tibia sags sign, posterior drawer test, and Lachman test were negative. At last follow-up, the knee range of motion (ROM) returned to normal in all cases. The Lysholm score was 92.3 ± 2.0, showing significant difference when compared with preoperative score (t= — 34.32, P=0.00). According to the IKDC rating criteria, 26 cases were classified as grade A and 6 cases as grade B at last follow-up, showing significant difference when compared with preoperative grade (Z= — 5.57, P=0.00). Conclusion Arthroscopic single-bundle reconstruction of PCL with remnant preservation and quadrupled hamstring tendons has advantages of minimal trauma, simple operation, and good knee function recovery.

    Release date:2016-08-31 04:12 Export PDF Favorites Scan
  • EFFECT OF POSTERIOR CRUCIATE LIGAMENT RETAINING OR NOT ON KNEE-JOINT PROPRIOCEPTION

    Objective To analyze the effect of the posterior cruciate ligament (PCL) retaining or not on knee-joint proprioception by comparing the proprioceptive difference between PCL retaining and no PCL retaining in total knee arthroplasty (TKA). Methods Between June 2009 and June 2010, 38 osteoarthritis patients meeting the inclusion criteria were divided into PCL retaining group (group A, n=19) and PCL-substituting group (group B, n=19) according to the random number table. There was no significant difference in gender, age, disease duration, the range of motion of the knee between 2 groups (P gt; 0.05). The effectiveness and the knee-joint proprioception were separately assessed by the Western Ontario and McMaster University Osteoarthritis Index (WOMAC) score and the passive angle reproduction test (30, 60, and 90° of knee flexion) preoperatively and 12 months postoperatively. Results All incisons healed by first intention, without complications of infection, fracture, and deep vein thrombosis of lower limb. The patients were followed up 12-17 months (mean, 14.1 months). The knee function after operation was obviously improved when compared with preoperative one; significant differences were observed in the WOMAC scores and the results of passive angle reproduction test between at preoperation and at 12 months after operation (P lt; 0.05), but no significant difference was found between group A and group B (P gt; 0.05). Conclusion Whether PCL retaining or not in TKA both can improve knee-joint proprioception, and no obvious difference between them.

    Release date:2016-08-31 04:07 Export PDF Favorites Scan
  • THREE-DIMENSIONAL VISUALIZATION OF INTERCONDYLAR NOTCH BASED ON MRI TWO-DIMENSIONAL IMAGES

    Objective To study the feasibility of virtual intercondylar notchplasty by applying MRI two-dimensional (2D) images to reconstruct three-dimensional (3D) images and measure the size of intercondylar notch. Methods Thirty healthy volunteers who had no knee joint disease and surgery history were selected. There were 15 females and 15 males with an age range of 20-30 years, weight range of 45-74 kg, and height range of 150-185 cm. They were divided into male group and female group, and the knees of each group were divided into 2 subgroups (the left group and right group). MRI scan of the left and right knees was performed, and the 2D images of MRI were imported into Mimics10.01 medical image control system for 3D reconstruction. The related anatomical data as follows were measured from the 3D digital model and analyzed by statistical software: notch width (NW), condylar width (CW), and notch width index (NWI). Then the 3D knee images of patients with anterior cruciate ligament (ACL) injury were collected between January and March 2010, and 4 patients with narrow intercondylar notch (NWI≤0.2) were selected for reconstructing the 3D model of the knee and simulating the intercondylar notch plasty. Then, the volume of osteotomy in 3D model was calculated and applied in the ACL reconstruction surgery, and whether the graft had impingement with intercondylar notch or not was evaluated. Results There were significant differences in NW and CW between male group and female group (P≤lt;≤0.05), but no significant difference was found in the NWI (P≤gt;≤0.05). And there was no significant difference in NW, CW, and NWI between the left and right knees both in male group and female group (P≤gt;≤0.05). After ACL reconstruction and intercondylar notchplasty, the shape of intercondylar notch became normal (NWI≤gt;≤0.22), no impingement occurred between the graft and intercondylar notch under arthroscopy within 3-month follow-up. Conclusion The shape of intercondylar notch of 3D model based on MRI 2D images is similar to the real intercondylar notch. NWI is one of important indexes which can reflect the narrow level of intercondylar notch. The virtual intercondylar notchplasty may provide preoperative plan and guidence for ACL reconstruction operation to avoid the impingement between graft and intercondylar notch after surgery.

    Release date:2016-08-31 04:21 Export PDF Favorites Scan
  • SURGICAL TREATMENT OF Segond FRACTURE AND COMPLICATIONS

    Objective To investigate the injury mechanism, clinical characteristics, and treatments of Segond fracture and complications. Methods Fifteen patients suffering from Segond fracture were treated between January 2007 and December 2011. There were 10 males and 5 females, aged 16-50 years (mean, 31.8 years). Fracture was caused by traffic accident in 8 cases, by sports in 6 cases, and by bruise in 1 case. Before operation, the knee range of motion (ROM) was (36.60 ± 8.94)°; the Lysholm score was 32.27 ± 3.73; and the International Knee Documentation Committee (IKDC) score was 42.34 ± 4.97. The duration from injury to operation was 1-3 weeks with an average of 1.2 weeks. In 12 patients having associated anterior cruciate ligament (ACL) injury, arthroscopic reconstruction of ACL was performed with allogeneic anterior tibial tendon; in 2 patients having associated avulsion fracture of the intercondylar eminence of the tibia, arthroscopic fracture reduction and fixation with Orthocord wire were performed. In 8 patients having associated meniscus injury, meniscus suture and meniscectomy were performed in 3 and 5 patients, respectively. In 7 patients having associated collateral ligament injury, conservative treatment was given in 5 patients, and medial collateral ligament was repair in 2 patients. Results All incisions healed primarily without complications of infection and nerve or blood vessel injury. All the patient were followed up 12-16 months (mean, 14.3 months). At 12 months after operation, the results of anterior drawer test, Lachman test, and lateral stress test were all negative. The knee ROM was (129.27 ± 5.89)°, the IKDC score and Lysholm score were significantly increased to 89.45 ± 3.05 and 87.87 ± 4.12 at 12 months after operation; all showing significant differences when compared with preoperative values (P lt; 0.05). Conclusion Segond fracture is often combined with ACL, collateral ligament, and meniscus injuries, and the evidence of Segond fracture can bly suggests the knee injury. Personalized treatment should be chosen according to complications.

    Release date:2016-08-31 04:12 Export PDF Favorites Scan
  • EFFECTIVENESS OF ARTHROSCOPIC TREATMENT OF ANTERIOR CRUCIATE LIGAMENT TIBIAL EMINENCE AVULSION FRACTURE WITH NON-ABSORBABLE SUTURE FIXATION COMBINED WITH MINI-PLATE

    Objective To evaluate the surgical techniques and effectiveness of arthroscopic treatment of anterior cruciate ligament (ACL) tibial eminence avulsion fracture with non-absorbable suture fixation combined with the mini-plate. Methods Between January 2009 and March 2012, 32 patients with ACL tibial eminence avulsion fractures were treated. There were 18 males and 14 females, aged 12-40 years (mean, 17.5 years). The injury causes included traffic accident injury in 15 cases, sport injury in 6 cases, and falling injury in 11 cases. The time from injury to operation ranged 7-18 days with an average of 9.5 days. Before operation, the results of Lachman test were all positive; the Lysholm score was 52.13 ± 4.22 and the International Knee Documentation Committee (IKDC) score was 44.82 ± 2.44. According to Meyers-McKeever classification criteria, there were 12 cases of type II and 20 cases of type III. After arthroscopic poking reduction of fracture, tibial eminence avulsion fractures were fixed with the Ethibond non-absorbable sutures bypass figure-of-eight tibial tunnel combined with the metacarpal and phalangeal mini-plate. Results Primary healing was obtained in all incisions; no joint infection or skin necrosis occurred after operation. All patients were followed up with an average time of 22.4 months (range, 12-50 months). The patients showed negative Lachman test at 12 weeks after operation. Except 3 patients having knee extension limitation at last follow-up, the knee extension range of motion (ROM) was normal in the other patients; the knee flexion ROM was normal in all patients. The Lysholm score and IKDC score were significantly improved to 94.19 ± 0.93 and 94.35 ± 1.22 at last follow-up, showing significant differences when compared with preoperative values (t=55.080, P=0.000; t=101.715, P=0.000). Conclusion The arthroscopic treatment of ACL tibial eminence avulsion fracture with Ethibond non-absorbable suture fixation combined with mini-plate is an effective procedure with the advantages of minimal trauma, reliable fixation, and satisfactory recovery of the knee joint function.

    Release date:2016-08-31 04:12 Export PDF Favorites Scan