Objective To improve the safety of the percutaneous anterior transarticular screw fixation (PATSF) by measuring the parameters related to PATSF. Methods Spiral CT scan and three-dimensional reconstructions of the atlantoaxis were performed in 50 adult volunteers. The section of inner margin of atlantal superior articular facet, the coronal plane ofvertebral artery cavity, and the sagittal plane of atlano-axis were obtained with multiplanar reconstruction on hel ical CT. The atlantoaxial vertebral structure and the direction of vertebral artery cavity were observed. The parameters related to PATSF were measured and analysed. Results The suitable position of screw insertion was 4.0 mm from the midpoint of the axoidean anteroinferior margin. The maximum external angle of PATSF was (29.89 ± 1.41)°; the minimum external angle was (4.37±0.87)°; the maximum backward angle was (32.41 ± 1.66)°; the optimal external angle was (17.13 ± 0.88)°; the optimal backward angle was (17.62 ± 1.03)°; and the optimal screw length was (41.57±0.79) mm. The atlantoaxial articular facial diameter was (16.71 ± 1.61) mm; the maximum distance of atlantal lateral displacement was (6.96 ± 1.09) mm; and the ratio of them was 41.80% ± 5.69%. Conclusion The optimal insertion of PATSF is safe and rel iable. The screw can be inserted when the displacement of the atlantal lateral mass is in a certain degree.
Objective To evaluate the clinical results of bioabsorbable interference screw in knee ligament reconstruction. Methods From April 2002 to August 2004, 39 patients with knee ligament injury were treated, including 33 males and6 females with a median age of 25 years (15 to 65 years). The involved ligament included 29 anterior cruciate ligament of knee(ACL), 6 posterior cruciate ligament of knee(PCL),4 combined ACL and PCL, 3 medial collateral or lateral collateral ligaments of knee point and 1 posterolateral complex injury of knee. All of patients underwent anatomic ligament reconstructions under arthroscopy or open surgery by autografts and fixation with bioabsorbable interference screw. Results All 34 patients were followed up 6 to 28 months (mean 13.7months). The patients were evaluated by Lysholm knee functional scales, the knee scores were 43.6±13.4 before operation and 85.4±16.3 after operation, showing significant difference (Plt;0.05). There was no limitation of rangeof motion and loosening of the screw. However, one case suffered from infection, and 3 cases suffered from effusion and synovitis after surgery and recovered after management. Conclusion Bioabsorbable interference screw fixation is a reliable method in knee ligament reconstruction and is effective to restore knee joint stability.
Objective To investigate the radiographic and clinical outcomes of dorsal intercarpal ligament capsulodesis (DILC) procedure for chronic static scapholunate dissociation. Methods Between January 2008 and January 2011, 12 patients with chronic static scapholunate dissociation were treated with DILC. Of 12 cases, 10 were male and 2 were female with an average age of 42 years (range, 20-66 years). All injuries were caused by falling. The interval from injury to surgery was 3-19 months (mean, 8 months). Physical examination at admission showed wrist tenderness and limited range of motion (ROM). Radiological examination showed that scapholunate gap was greater than 3 mm on posteroanterior view, and scapholunate angle more than 60° on the lateral view. Before operation, the grip strength was (25.4±8.2) kg; the wrist ROM was (56.7±11.5)° in flexion and (52.0±15.2)° in extension; visual analogue scale (VAS) score was 6.3±1.4; and disabilities of arm, shoulder & hand (DASH) score was 39.5±7.4. According to Garcia-Elias staging criteria, all cases were rated as stage 4, indicating that the scapholunate interosseous ligament was completely injured and reduction could easily be obtained. Eight patients had wrist instability. Results Primary healing of incision was achieved, no complication was found. All patients were followed up 13-34 months (mean, 15.9 months). During surgery, all deformities were corrected completely, but 7 patients (58%) recurred at 1 month after Kirschner wire removal. Compared with preoperative ones, the scapholunate gap, scapholunate angle, radiolunate angle, lunocapitate angle, and wrist height ratio at 1 month after Kirschner wire removal and last follow-up showed no significant difference (P > 0.05); the wrist flexion and extension ROM were significantly decreaed to (46.8±7.2)° and (42.0±9.0)° at last follow-up (P < 0.05); the grip strength was significantly increased to (32.7±9.6) kg at last follow-up (P < 0.05); VAS score and DASH score were improved to 1.7±1.0 and 8.1±8.7 (P < 0.05). Conclusion Carpal collapse will recur in short time after DILC. DILC is not the best way to treat chronic static scapholunate dissociation.
ObjectiveTo study the effect of the femoral tunnel position on the knee function recovery after medial patellofemoral ligament (MPFL) reconstruction. MethodsA retrospective analysis was made on the clinical date of 43 cases (43 knees) of recurrent patellar dislocation undergoing MPFL reconstruction and patellofemoral lateral retinaculum lysis between August 2013 and March 2014. There were 12 males and 31 females, aged 19.4 years on average (range, 9-35 years). All patients had trauma history and recurrent dislocations. The results of apprehesion test and J syndrom were positive. The patellar tilt test showed patellofemoral lateral retinaculum was tension. The effectiveness was evaluated using Lysholm knee functional score after operation. The distance from the center of the femoral tunnel to the femoral isometric point was measured on CT three dimensional reconstruction image. Whether the femoral tunnel position was isometric was evaluated. The correlation was analyzed between the distance from the center of the femoral tunnel to the femoral isometric point and Lysholm score. ResultsPrimary healing of incision was obtained in all patients. The patients were followed up 13-18 months (mean, 15 months). No patellar dislocation or subluxation occurred. The result of apprehensive test was negative. At last follow-up, the average Lysholm score was 93.8 (range, 83-100). The average distance from the center of the femoral tunnel to the femoral isometric point was 5.61 mm (range, 2-16 mm). The femoral tunnel position was isometric in 30 cases (69.8%) and non-isometric in 13 cases (30.2%). The distance from the center of the femoral tunnel to the femoral isometric point was negatively correlated with postoperative Lysholm score (r=-0.851, P=0.000). The postoperative Lysholm score was 95.7±2.3 in patients with isometric tunnel and was 89.4±3.5 in patients with non-isometric tunnel, showing significant difference (t=6.951, P=0.000). ConclusionFor patellofemoral joint instability, preparing the femoral isometric tunnel can establish a good foundation for the recovery of the knee function in MPFL reconstruction.
Objective To evaluate the effectiveness of anterior talofibular ligament repair in the treatment of lateral ankle stability and the effect of combined tarsal sinus syndrome on results. Methods Between December 2013 and October 2014, 47 cases of lateral ankle instability underwent anatomical repair of anterior talofibular ligament, and the clinical data were retrospectively analyzed. Of 47 cases, 32 had no tarsal sinus syndrome (group A); 15 had tarsal sinus syndrome (group B), arthroscopic debridement of tarsal sinus was performed at the same time. There was no significant difference in gender, age, disease duration, side, American Orthopaedic Foot and Ankle Society (AOFAS), Karlsson score, and Tegner movement function score between 2 groups (P>0.05). Results No early surgical complication of infection occurred, and primary healing of incision was obtained in 2 groups. The patients were followed up 20-31 months (mean, 26.0 months) in group A, and 20-31 months (mean, 24.7 months) in group B. Disappearance of ankle swelling, good joints movement, and recovery of normal walking were observed in all patients. At last follow-up, AOFAS score, Karlsson score, and Tegner movement function score were significantly improved when compared with preoperative ones in 2 groups (P<0.05), but no significant difference was found between 2 groups (P>0.05). No ankle instability recurrence was found during follow-up period. Conclusion The effectiveness of anatomical repair of anterior talofibular ligament in lateral ankle instability is satisfactory for patients with or without tarsal sinus syndrome.
ObjectiveTo introduce the method of prior-localization femoral tunnel by using a special positioning tool under the C-arm radiographic machine before surgery, and to study the effect on the knee function recovery after medial patellofemoral ligament (MPFL) reconstruction.MethodsBetween January 2014 and January 2016, 32 patients with recurrent unilateral knee patellar dislocation were treated by arthroscopic patellofemoral lateral retinaculum release and MPFL reconstruction. The femoral tunnel position during MPFL reconstruction was prior-localizated under C-arm radiographic machine before operation. There were 8 males and 24 females, aged from 15 to 37 years, with an average of 23.8 years. The time from injury to admission ranged from 1 to 24 months, with an average of 9.7 months. Isometric point distance was measured on CT three-dimensional reconstruction image after operation to evaluate whether the position of femoral tunnel was isometric, and knee joint function was evaluated by Lysholm score. Spearman correlation analysis was performed between isometric point distance and Lysholm score.ResultsAll the 32 patients were followed up 12-18 months (mean, 14.2 months). No symptoms of patellar subluxation or dislocation was found during follow-up. Patellar extrapolation test and patellar extrapolation fear test were negative. The isometric point distance was 1.5-5.9 mm (mean, 3.44 mm) at 3 days after operation. All femoral tunnels were located in equidistant tunnels. At last follow-up, the Lysholm score of the patients was 92.8±2.1, which was significantly improved when compared with preoperative score (54.4±2.8) (t=61.911, P=0.000). Isometric point distance was negatively correlated with Lysholm score (r=–0.454, P=0.009).ConclusionC-arm radiographic machine can locate the femoral tunnel position of MPFL easily and accurately before operation. The short-term and medium-term effectiveness are satisfactory, and the ionizing radiation injury caused by multiple fluoroscopy during operation is avoided.
ObjectiveTo compare the effectiveness of all-arthroscopic technique and modified open Broström technique in repair of anterior talofibular ligament (ATFL) for lateral instability of the ankle (LIA).MethodsA retrospective analysis was made on 65 patients who underwent ATFL repair with anchors for LIA between January 2014 and January 2017. The ATFL was repaired by all-arthroscopic technique in 35 patients (arthroscopic group) and modified open Broström technique in 30 patients (open group). There was no significant difference in age, gender, the side of injured ankle, the time from injury to operation, and preoperative anterior displacement of talus, tilt angle of talus, the Karlsson Ankle Functional (KAF) score, American Orthopaedic Foot and Ankle Society (AOFAS) score, and Japanese Society for Surgery of the foot ankle-hindfoot (JSSF) scale score between the two groups (P>0.05). The operation time, the intraoperative bleeding volume, and the length of time for surgery recovery were recorded. The anterior displacement of talus, the tilt angle of talus, KAF score, AOFAS score, and JSSF scale score were evaluated at 2 weeks, 3 months, and the last follow-up.ResultsAll patients were followed up 24-30 months, with an average of 26 months. The operation time, intraoperative bleeding volume, and the length of time for surgery recovery of arthroscopic group were superior to open group (P<0.05). There were 2 cases of temporary ankle and dorsum numbness and 1 case of thread reaction in arthroscopic group; and there were 2 cases of temporary ankle and dorsum numbness and 2 cases of thread reaction in open group. The AOFAS score, KAF score, and JSSF scale score in arthroscopic group were significantly higher than those in open group (P<0.05) at 2 weeks after operation; there was no significant difference between the two groups at 3 months and the last follow-up (P>0.05). There was no significant difference in the anterior displacement of talus and the tilt angle of talus between the two groups at 2 weeks, 3 months, and last follow-up (P>0.05).ConclusionCompared with the modified open Broström technique, the all-arthroscopic technique, as a minimally invasive technique, can achieve the same effectiveness, and has the advantages of shorter operation time, less intraoperative bleeding, and less pain in the early stage.
ObjectiveTo clarify the value of the cortical endo-button as an internal fixator in Latarjet procedure through biomechanical analysis.MethodsTen pairs of shoulder joints from 6-7 months old male pigs were selected. Each pair was randomly divided into screw group and endo-button group. A 25% glenoid defect model was created, and the porcine infraspinatus tendon and its associated bone were used to simulate conjoint tendon and coracoid process in human body. The bone grafts were fixed with two 3.5 mm screws and double cortical endo-buttons with high-strength sutures in screw group and endo-button group, respectively. The prepared glenoid defect model was fixed on a biomechanical test bench and optical markers were fixed on the glenoid and the bone block, respectively. Then fatigue test was performed to observe whether the graft or internal fixator would failed. During the test, the standard deviations of the relative displacement between the graft and the glenoid of two groups were measured by optical motion measure system for comparison. Finally the maximum failure load comparison was conducted and the maximum failure loads of the two groups were measured and compared.ResultsThere was no tendon tear, bone fracture, and other graft or internal fixation failure in the two groups during the fatigue test. The standard deviation of the relative displacement of the screw group was (0.007 87±0.001 44) mm, and that of the endo-button group was (0.034 88±0.011 10) mm, showing significant difference between the two groups (t=7.682, P=0.000). The maximum failure load was (265±39) N in screw group and (275±52) N in endo-button group, showing no significant difference between the two groups (t=1.386, P=0.199). There were 3 ways of failure: rupture at bone graft’s tunnel (6/10 from screw group, 3/10 from endo-button group), tendon tear at the cramp (2/10 from screw group, 2/10 from endo-button group), and tendon tear at the internal fixator interface (2/10 from screw group, 5/10 from endo-button group), showing no significant difference between the two groups (P=0.395).ConclusionAlthough the endo-button fixation fails to achieve the same strong fixation stability as the screw fixation, its fixation stability can achieve the clinical requirements. The two fixation methods can provide similar fixation strength when being used in Latarjet procedure.