west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "刘树义" 2 results
  • 三枚空心钉与动力髋螺钉结合空心钉治疗青壮年股骨颈骨折的比较研究

    目的 比较3 枚空心钉及动力髋螺钉(dynamic hip screw,DHS)结合空心钉治疗青壮年股骨颈骨折的临床疗效。 方法 2007 年10 月- 2009 年1 月,收治72 例青壮年股骨颈骨折患者。其中40 例采用3 枚空心钉固定(空心钉组):男21 例,女19 例;年龄20 ~ 50 岁,平均35.2 岁。车祸伤8 例,摔伤32 例。受伤至手术时间1 ~ 4 d,平均 2.7 d。32 例采用DHS 结合空心钉固定(结合组):男18 例,女14 例;年龄20 ~ 46 岁,平均37.4 岁。车祸伤6 例,摔伤26 例。受伤至手术时间1 ~ 4 d,平均2.5 d。两组患者一般资料比较,差异无统计学意义(P gt; 0.05),具有可比性。 结果 术后两组切口均Ⅰ期愈合。患者均获随访,随访时间12 ~ 26 个月,平均18.6 个月。空心钉组骨折愈合率为90%(36/40),结合组为100%(32/32);空心钉组股骨头坏死率为10.0%(4/40),结合组为9.4%(3/32)。末次随访髋关节功能按Harris 评分标准进行评价,空心钉组(85.2 ± 4.3)分,结合组(87.4 ± 3.9)分。以上指标两组比较差异均无统计学意义(P gt; 0.05)。 结论 采用3 枚空心钉或DHS 结合空心钉固定治疗青壮年股骨颈骨折均可获得较好疗效。

    Release date:2016-08-31 05:49 Export PDF Favorites Scan
  • LIMITED OPEN REDUCTION AND DOUBLE PLATES INTERNAL FIXATION FOR TREATMENT OF Vancouver TYPE B1 PERIPROSTHETIC FEMORAL FRACTURE AFTER HIP ARTHROPLASTY

    Objective To evaluate the effectiveness of limited open reduction and double plates internal fixation in the treatment of Vancouver type B1 periprosthetic femoral fracture after hip arthroplasty. Methods A retrospective analysis was made on the clinical data of 12 patients with Vancouver type B1 periprosthetic femoral fracture after hip arthroplasty between May 2007 and October 2012, who underwent limited open reduction and double plates internal fixation. Of 12 patients, 4 were male and 8 were female, aged 76-85 years (mean, 81.6 years); the left side was involved in 5 patients and the right side in 7 patients. The cement prosthesis was used in 3 cases and cementless prosthesis in 9 cases; double acting head of hip arthroplasty was performed in 4 cases and total hip arthroplasty in 8 cases. The median time from first hip arthroplasty to re-fracture was 13 months (range, 5 months-5 years). The causes of injury were traffic accident in 2 cases and falling in 10 cases. Combined fractures included contralateral tibial and fibular fractures and ipsilateral distal humeral fracture (1 case), ipsilateral proximal humeral fracture (2 cases), ipsilateral distal radial fracture (1 case), and rib fracture (1 case). The time from injury to operation was 5.6 days on average (range, 3-10 days). Results The incisions all healed by first intention, and no infection or deep venous thrombosis of lower extremity occurred. Twelve cases were followed up 6-24 months (mean, 13.3 months). One female patient died of acute myocardial infarction at 16 months after operation. All the fractures were healed, with X-ray healing time of 12.5 weeks on average (range, 10-16 weeks). The time of full weight bearing was 13 weeks on average (range, 10-18 weeks). Ten cases could walk freely after operation, and 2 cases could walk by the aid of walking aid appliance. At last follow-up, the Harris score of hip function was 87.3 on average (range, 75-93). Conclusion The method of limited open reduction and double plates internal fixation for Vancouver type B1 periprosthetic femoral fracture after hip arthroplasty is effective in maintaining stability, protecting blood supply, promoting fracture healing, and doing functional exercise early. The long-term effectiveness needs further observation.

    Release date:2016-08-31 10:53 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content