find Author "刘睿" 10 results
  • Therapeutic effects of vitrectomy on terminal bullous retinal detachment

    Objective To evaluate the therapeutic effect of vitrectomy on bullous retinal detachment. Methods The clinical data of 7 patients (9 eyes) with bullous retinal detachment who had undergone vitrectomy due to useless photocoagulation were retrospectively analyzed. Bullous retinal detachment of the patients had been diagnosed by examination of slit-lamp microscope, three-mirror gonioscope, indirect ophthalmoscope, B-mode ultrasound, and fundus fluorescein angiography. All of the affected eyes underwent vitrectomy with closed triple incisions through the pars plana after release of subretinal liquid under the local anaesthesia. The cortex of vitreous body was taken out, and exsuction of subretinal liquid was carried out via retinal incision. Photocoagulation closed the incision and the effusion area of the retina, and intraocular filling matter was injected after exchange of air and liquid. The follow-up period lasted 3 months to 8 years with the average period of 47 months. Results Reattached retina was found in all of the affected eyes during the follow-up period. One eye underwent a second vitrectomy due to local retinal redetachment caused by a new retinal hole formed by the pull of pre-retinal proliferative membrane and a silicon vesicle entered the subretinal space, but the retina reattached after 1-year follow-up examination. The visual acuity impr oved in different degree after the operation in 8 eyes, but remained unchanged in 1 eye. Conclusion Vitrectomy for terminal bullous retinal detachment may promote the reattachment of retina safely and effectively, and save partial visual acuity of the affected eyes. (Chin J Ocul Fundus Dis, 2006, 22:299-301)

    Release date:2016-09-02 05:51 Export PDF Favorites Scan
  • Application of TME Combined with Dual Stapler Technique in 85 Cases With Low Rectal Cancer

    目的:探讨全直肠系膜切除术(total mesorectal excision,TME)结合双吻合器(DST)治疗低位直肠癌的效果及临床价值。方法:对我院85 例低位直肠癌患者采用 TME和DST联合治疗的方法,观察治疗后的排便功能及疗效.结果:所有患者手术均顺利,无吻合口瘘和狭窄,切割环均完整,无手术闭合失败及手术死亡。随访时间6 个月~5年,局部复发率4例(4.7%)。排便控制功能:优75 例(88.2%),良9 例(10.6%),差1 例(1.2%)。结论:TME和 DST联用治疗低位直肠癌,保肛效果满意,并发症少,提高了患者的生存质量,值得临床推广。

    Release date:2016-09-08 10:02 Export PDF Favorites Scan
  • Effect of persistent flickering stimulus on electroretinogram and histopathology of guinea pigs

    Objective To observe the effect of persistent flickering stimulus on the structure and function of retina in guinea pigs during a developmentally sensitive period.Methods Twenty-four two- week-old guinea pigs were randomly divided into flicker light (FL) group and control group, with 12 guinea pigs in each group. Animals in FL group were raised under 500 Lux illumination with a duty diurnal cycle of 50% at a flash rate of 0.5 Hz. Animals in control group were reared under steady 500 Lux illumination. Light emitting diode (LED) lamps were used for lighting under a 12-hour light/12-hour dark cycle. After the collection of fundus photographs and electroretinograms recorded at week 12, eyeballs were taken out, three dimensions were measured, and histopathological changes were examined.Results Compared to control group, tessellated fundus in FL group appeared more prevalent; implicit time of ldquo;ardquo; waves were prolonged in electroretinogram; the eyeballs were increased in horizontal, vertical, axial dimensions by (0.89plusmn;0.30), (0.69plusmn;0.20) and (0.96plusmn;0.30) mm respectively, the differences between two groups were statistically significant (t=12.7,11.9,15.8;P<0.05). The gap of sclera collagen fiber was slightly widened.The photoreceptor layer was more likely to develop a disordered outer segment, which contained deciduous disc membranes.Conclusion Persistent flickering stimulus is attended by development of excessive ocular enlargement,which could affect the retinal structure and function of photoreceptors.

    Release date:2016-09-02 05:26 Export PDF Favorites Scan
  • Clinical efficacy of reduction ascending aortoplasty with wedge resection in adult patients undergoing aortic valve replacement: A single-center retrospective study

    ObjectiveTo assess mid-term outcomes of reduction ascending aortoplasty (RAA) in adult patients undergoing aortic valve replacement (AVR).MethodsWe retrospecctively analyzed clinical data of 30 adult patients with aortic valve diseases and ascending aortic dilatation in Fuwai Hospital from 2010 to 2019. There were 20 males and 10 females with an age of 38-72 (55.73±9.95) years. All patients received AVR+RAA using the wedge resection technique. Ascending aorta diameter (AAD) was measured by echocardiography or CT scan preoperatively and postoperatively.ResultsThere was no perioperative death. The mean preoperative and postoperative AAD in all patients were 48.23±3.69 mm and 37.60±5.02 mm, respectively. And the mean AAD of follow-up was 40.53±4.65 mm. There was a statistical difference in AAD between preoperation and postoperation, postoperation and final follow-up, preoperation and final follow-up. The median follow-up time was 28.50 (12-114) months. The median rate of increase in AAD postoperatively was 0.76 mm per year. And the rate of increase was ≥3 mm per year in 5 patients, while ≥5 mm per year in 4 patients with indications for reoperation. ConclusionMid-term outcomes of RAA in adult patients undergoing aortic valve replacement using the wedge resection technique are satisfying and encouraging. However, some patients still need surgical re-intervention.

    Release date: Export PDF Favorites Scan
  • Repair of resurfacing soft tissue defect of hand with radial collateral artery polyfoliate perforator flap

    Objective To explore the feasibility and effectiveness of radial collateral artery polyfoliate perforator flap in repair of resurfacing soft tissue defect of hand. Methods Between September 2017 and September 2018, the radial collateral artery polyfoliate perforator flaps were transplanted to repair 5 cases of two adjacent wounds of hand and wide or irregular wounds. All patients were male, aged from 27 to 52 years, with an average of 42.5 years. The time from injury to admission was 4 hours to 3 weeks, with an average of 7.3 days. Causes of injury included traffic accident in 2 cases, crushing injury in 2 cases, and paint injection injury in 1 case. The wounds were located at the dorsum of hand in 3 cases, the dorsum of finger in 1 case, and the thumb and thumb web in 1 case. The area of wound ranged from 8 cm×6 cm to 10 cm×8 cm. The area of skin flap ranged from 6.0 cm×3.0 cm to 11.0 cm×4.5 cm, all of which carried the posterior cutaneous nerve of the arm, and the donor site was closed directly. Results All flaps survived and healed by first intention. All patients were followed up 3-11 months (mean, 6.5 months). The patients were satisfied with the appearance of hands. The flaps were not bulky, and the color and texture were similar to the hand. There was only linear scar in the donor site, no radial nerve injury occurred, and elbow joint function was not affected. One patient underwent finger-splitting and skin flap thinning at 6 months after operation. Conclusion The radial collateral artery polyfoliate perforator flap is a good method for repairing two adjacent wounds and wide or irregular wounds of hand.

    Release date:2019-06-04 02:16 Export PDF Favorites Scan
  • 游离桡侧副动脉嵌合穿支皮瓣修复踇甲瓣供区复合组织缺损

    目的总结游离桡侧副动脉嵌合穿支皮瓣移植修复踇甲瓣供区复合组织缺损的疗效。方法2020年4月—2021年3月,采用游离桡侧副动脉嵌合穿支皮瓣修复7例踇甲瓣切取后遗留的复合组织缺损。男3例,女4例;年龄7~44岁,中位年龄20岁。踇甲瓣切取后,遗留皮肤软组织缺损范围为5 cm×2 cm~9 cm×6 cm;均合并大小为1.5 cm×1.0 cm~3.0 cm×1.0 cm的骨缺损。采用游离桡侧副动脉嵌合穿支皮瓣修复创面,皮瓣切取范围为6.0 cm×2.5 cm~10.0 cm×5.0 cm;均携带肱骨瓣修复骨缺损、臂后侧皮神经重建感觉。上臂供区创面直接闭合。结果 术后7例皮瓣均顺利成活,创面Ⅰ期愈合。患者均获随访,随访时间7~15个月,平均14个月。桡侧副动脉嵌合穿支皮瓣无臃肿,颜色、质地与足背部皮肤接近;肱骨瓣均愈合。末次随访时,6例皮瓣两点辨别觉为6~10 mm,平均7.5 mm;1例恢复保护性感觉。上臂皮瓣供区仅留线性瘢痕。结论 游离桡侧副动脉嵌合穿支皮瓣可同时携带骨瓣及皮神经,修复踇甲瓣切取后遗留的复合组织缺损。

    Release date: Export PDF Favorites Scan
  • Assessment of the internal mammary artery using ultrasound in patients with coronary artery disease before coronary artery bypass grafting

    ObjectiveTo investigate the feasibility and effectiveness of using ultrasound to evaluate the internal mammary artery (IMA) and explore the related factors affecting the quality of IMA.MethodsFrom July 2020 to January 2021, for patients who underwent coronary artery bypass grafting at the Department of Cardiovascular Surgery, Fuwai Hospital, ultrasound was applied to measure bilateral IMA at the parasternal second intercostal space. There were 62 males and 18 females with an average age of 59.9±8.3 years. The clinical data of the patients were recorded and analyzed.ResultsA total of 160 IMA were measured. The IMA was detected in 99.4% (159/160), and the one that was not measured was proved to be occluded by enhanced CT. A total of 157 (98.1%) IMA intima were smooth, 2 (1.3%) were found to have uneven intimal thickening and less smooth, and only 1 (0.6%) was occluded. The intravascular diameter, peak systolic flow rate, peak diastolic flow rate, and blood flow rate of the left second intercostal IMA were 1.9±0.3 mm, 66.8±17.7 cm/s, 6.4 (0.0, 9.7) cm/s, 19.7±9.4 mL/min; and those of the right one were 2.1±0.3 mm, 69.7±18.5 cm/s, 6.0 (0.0, 9.2) cm/s and 22.8±11.5 mL/min, respectively. IMA vessel diameter and blood flow were greater on the right than those on the left side in the same individual (P<0.01). In univariate analysis, sex and body surface area were the factors that influenced the size of the IMA vessel among different individuals, and by linear regression analysis, the size of the IMA vessel was only related to body surface area among different individuals. On univariate analysis, diabetes mellitus was the only factor affecting IMA blood flow, with a mean reduction in blood flow of 18.4% (left) and 21.7% (right) in the diabetic group (P<0.05).ConclusionPreoperative evaluation of the IMA using ultrasound over the parasternal second intercostal space is easy, noninvasive, and has a high success rate. The internal diameter of the IMA is positively correlated with body surface area, and blood flow is significantly reduced in patients with diabetes.

    Release date: Export PDF Favorites Scan
  • Reduction ascending aortoplasty in adult patients undergoing aortic valve replacement: Aorta diameter change, mid- and long-term clinical results

    ObjectiveTo assess mid- and long-term outcomes and share our clinical method of reduction ascending aortoplasty (RAA) in adult patients undergoing aortic valve replacement (AVR).MethodsWe retrospectively analyzed clinical data of 41 adult patients with aortic valve disease and ascending aortic dilatation before and after operation of RAA+AVR in Fuwai Hospital from January 2010 to July 2017. There were 28 male and 13 female patients aged 28-76 (53.34±12.06) years. Twenty-three patients received AVR+RAA using the sandwich technique (a sandwich technique group), while other 18 patients received AVR+ascending aorta wrap (a wrapping technique group). Ascending aorta diameter (AAD) was measured by echocardiography or CT scan preoperatively and postoperatively.ResultsThere was no perioperative death. The mean preoperative AAD in the sandwich technique group and the wrapping technique group (47.04±3.44 mm vs. 46.67±2.83 mm, P=0.709) was not statistically different. The mean postoperative AAD (35.87±3.81 mm vs. 35.50±5.67 mm, P=0.804), and the mean AAD at the end of follow-up (41.26±6.54 mm vs. 38.28±4.79 mm, P=0.113) were also not statistically different between the two groups. There were statistical differences in AAD before, after operation and at follow-up in each group. All 41 patients were followed up for 23-108 (57.07±28.60) months, with a median follow-up of 51.00 months. Compared with that before discharge, the AAD growth rate at the last follow-up was –1.50-6.78 mm/year, with a median growth rate of 0.70 mm/year, and only 3 patients had an annual growth rate of above 3 mm/year.ConclusionMid- and long-term outcomes of RAA in adult patients undergoing AVR with both methods are satisfying and encouraging.

    Release date: Export PDF Favorites Scan
  • Clinical application of Flow-through chimeric anterolateral thigh perforator flap

    Objective To investigate the feasibility and efficacy of the Flow-through chimeric anterolateral thigh perforator (ALTP) flap for one-stage repair and revascularization in complex defects of the extremities. Methods Between May 2014 and June 2017, 6 patients with soft tissue defects on the limbs combined with dead space, bone defects, or tendon and joint exposure, were reconstructed with the Flow-through chimeric ALTP flap. All 6 patients were male. The patients’ mean age was 44 years (range, 26-60 years). The mechanisms of injury were traffic accidents in 4 cases, wringer injury in 1 case, and bruise injury caused by heavy object in 1 case. The defects located at the lower extremity in 5 cases and at the upper extremity in 1 case. The area of the wound ranged from 7 cm×4 cm to 26 cm×10 cm. There were 3 cases of bone defect, 3 cases of joint and tendon exposure, 2 cases of chronic osteomyelitis, and 2 cases of main artery injury. The muscle flap was inserted into the deep dead space, with perforator flap for superficial defect. The area of perforator flap ranged from 10 cm×5 cm to 28 cm×11 cm and the area of muscle flap ranged from 5 cm×2 cm to 20 cm×5 cm. The defects on the donor sites were closed directly. Results All the flaps were survival without infection and vascular crisis. The wounds of recipient and donor sites healed at first intention. The patients were followed up 3- 24 months (mean, 10 months). Good color and texture of flaps was achieved. The reconstructed main artery patency was achieved and the end of the affected limb was well transported. Only linear scar left on the donor site on thigh with no malfunction. Conclusion The Flow-through chimeric ALTP flap can construct three-dimensional soft tissue defects without sacrificing the recipient vessels. The Flow-through chimeric ALTP flap is an reliable and ideal method for reconstruction of complex wounds in the limbs with dead space and with or without recipient major vessels injury.

    Release date:2018-07-30 05:33 Export PDF Favorites Scan
  • Repair of skin and soft tissue defects in extremities with the superior lateral genicular artery perforator flap

    ObjectiveTo investigate the feasibility and effectiveness of the superior lateral genicular artery perforator flap for repairing of soft tissue defects in extremities.MethodsBetween September 2010 and October 2017, 11 cases of skin and soft tissue in extremities were repaired with the superior lateral genicular artery perforator flap. There were 10 males and 1 female, with an average age of 37.6 years (range, 6-72 years). The causes of injury were traffic accident in 6 cases, machine injury in 1 case, falling down injury in 1 case, falling from height in 1 case, crushing injury in 1 case, and electric injury in 1 case. The defects located at the forearm in 1 case, knee in 5 cases, popliteal fossa in 2 cases, shank in 1 case, and foot and ankle in 2 cases. The area of the wound ranged from 8.0 cm×4.5 cm to 27.0 cm×8.0 cm. The interval from injury to admission was 6 days on average (range, 3-12 days). The area of perforator flap ranged from 9.0 cm×5.5 cm to 28.0 cm×9.0 cm. There were 8 cases of pedicle flap and 3 cases of free flap. All the donor sites were closed directly.ResultsEight flaps survived without any complications and the donor sites healed by first intention. Two flaps had arterial crisis and 1 flap had venous crisis after operation, and the wounds healed after symptomatic treatment. There was no hematoma and secondary infections in all patients after operation. Ten patients were followed up 2-48 months (mean, 13.1 months). All flaps had satisfied appearance and texture. There was no motion limitations in the hip and knee joints of the operated legs.ConclusionThe superior lateral genicular artery perforator flap not only can be used to repair the soft tissue defect around the knee joint as pedicle flap, but also can be used to repair the forearm and foot skin and soft tissue defects as free flap, which is a feasible way to repair soft tissue defects in extremities.

    Release date:2019-05-06 04:46 Export PDF Favorites Scan