west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "吴尧" 6 results
  • Economic evaluation methods for anticancer-drugs with basket trial design

    ObjectiveTo introduce economic evaluation methods for anticancer-drugs with basket trial design, and to provide references for related research and decision-making. MethodsA case analysis was conducted on economic evaluation methods for anticancer-drugs with basket trial design, which was issued by Canadian Agency for Drugs and Technologies in Health (CADTH) in the Economic Guidance Report. Moreover, both the advantages and disadvantages of the methods were analyzed in accordance with the characteristics of basket trials. ResultsPooled analysis and tumor-specific analysis were two methods frequently employed in the case analysis. However, great uncertainties were available in both of them. The uncertainty of the former was mainly reflected in the heterogeneity of the targeted population, while the uncertainty of the latter was mainly shown in the insufficient sample size of the subgroup. ConclusionCurrently, economic evaluation methods for anticancer-drugs with basket trial design are immature. Thus, researchers are required to explore the methods of innovation evaluation with lower uncertainty; reimbursement decision-makers should fully consider the uncertainty of evaluation results and enterprises should collect the real-world data for the demands of evaluation to promote the reasonable allocation of healthcare resources in China.

    Release date: Export PDF Favorites Scan
  • APPLICATION OF FREE BILOBED MEDIAL SURAL ARTERY PERFORATOR FLAP FOR REPAIRING PENETRATING WOUND OF FOOT

    ObjectiveTo explore the effectiveness of the free bilobed medial sural artery perforator (BMSAP) flap to repair penetrating wound of the foot. MethodsBetween April 2012 and October 2014, 7 cases of foot penetrating wounds were treated with the BMSAP flap. There were 5 males and 2 females, aged from 21 to 43 years (mean, 31.5 years). The causes of injury included the crush injury (4 cases), blunt puncture (2 cases), and firearm injury (1 case). The wound was located at the left foot in 4 cases and at the right foot in 3 cases. There were longitudinal penetrating injury in 5 cases and transverse penetrating injury in 2 cases. The size of wound ranged from 4 cm×3 cm to 9 cm×7 cm. The interval between injury and admission was 0.5-5.5 hours (mean, 3.2 hours). The free BMSAP flap of 5 cm×4 cm-10 cm×8 cm in size was used to repair the wounds on both sides and to reconstruct the sensation. The donor site was sutured or repaired with skin graft. ResultsAfter operation, 1 case had distal flap necrosis, the flap survived after dressing change; 1 case had wound infection, and delayed healing was obtained after drainage; and the flap survived completely, and primary healing was obtained in the other 5 cases. The skin grafts survived and healing of incision by first intention was observed at donor sites. The patients were followed up from 7 to 24 months (mean, 12.5 months). The flap had soft texture and similar color to normal skin. According to the British Medical Research Council (BMRC) sensory function assessment system, 1 case was rated as S2, 4 cases as S3, and 2 cases as S3+. The American Orthopaedic Foot and Ankle Society (AOFAS) score was 86-97 (mean, 93.6); the results were excellent in 6 cases and good in 1 case. ConclusionThe free BMSAP flap is very suitable to repair penetrating wound of the foot. The flap has the advantages of repairing the two wounds at the same time and reconstructing skin sensation as well.

    Release date: Export PDF Favorites Scan
  • Repair of distal phalanx finger wound with modified great toe fibular flap with distal artery pedicle as reflux vein

    ObjectiveTo investigate the effectiveness of the modified great toe fibular flap using the distal artery pedicle as reflux vein for repairing distal phalanx finger wound.MethodsBetween June 2018 and January 2020, 15 patients who suffered tissue defect of the distal phalanx finger were treated, including 12 males and 3 females, the average age was 40.2 years (range, 24-56 years). All of them were caused by machine crush injury. There were 2 cases of thumb, 6 cases of index finger, 3 cases of middle finger, 3 cases of ring finger, and 1 case of little finger. The defects ranged from 1.7 cm×1.3 cm to 3.0 cm×2.0 cm. The time from injury to admission was 0.6-4 hours, with an average of 2.3 hours. The medial fibular proper digital artery was further dissociated to the distal end and anastomosed with the recipient vein as the reflux vein. The area of flaps ranged from 2.0 cm×1.5 cm to 3.2 cm×2.2 cm.ResultsAll the flaps survived without vascular crisis, and the wounds healed by first intention. Except for 1 case that the suture was too tight, the incision was partially split after the stitches were removed, and it healed spontaneously after dressing change, the other patients had good healing of the donor site incision and normal foot function. All 15 patients were followed up 3-18 months, with an average of 9.3 months. The appearance of finger pulps were satisfactory with full and threaded. The color, texture, and elasticity of the flaps were good, and the two-point discrimination was 6-8 mm at last follow-up. The flexion and extension of fingers were normal. At last follow-up, hand function was evaluated according to the upper limb function evaluation trial standard of the Chinese Medical Association Hand Surgery Society, and the results were 13 cases of excellent and 2 cases of good.ConclusionModified great toe fibular flap using the distal arterial pedicle as a reflux vein can improve the venous drainage of the flap and contribute to increase the success rate of the flap without additional injury.

    Release date:2021-02-24 05:33 Export PDF Favorites Scan
  • Research progress of clinical application of medial sural artery perforator flap

    ObjectiveTo review the research progress of the clinical application of the medial sural artery perforator flap (MSAPF).MethodsThe relevant domestic and abroad literature on the clinical application of MSAPF was extensively consulted, and the research progress were summarized and analyzed in aspect of its definition, anatomical characteristics, clinical application, surgical resection and improvement, and advantages and disadvantages of flaps, etc.ResultsMSAPF has the advantages of relatively constant anatomical position, thin flap texture, long vascular pedicle, large vessel diameter, no sacrifice of main blood vessels, concealed donor site, no hair, and fewer complications; it can carry nerves, tendons, and muscles to construct chimeric flaps to repair three-dimensional wounds; and can also repair wounds with high aesthetic and functional requirements such as hand, foot and ankle, head and neck, etc.ConclusionThe MSAPF is a versatile, various forms, functional diversification, and three-dimensional flap donor site with various application forms and ideal repair effectiveness.

    Release date:2021-04-27 09:12 Export PDF Favorites Scan
  • Comparative study on Sichuan yak pericardium and Australian cattle pericardium

    Currently, as the key raw material of artificial biological heart valve, bovine pericardium is mainly depend on import and has become a “bottleneck” challenge, greatly limiting the development of domestic biological heart valve. Therefore, the localization of bovine pericardium is extremely urgent. In this study, the pericardium of Sichuan yak was compared with that of Australian cattle in terms of fundamental properties and anti-calcification performance. The results demonstrated that the appearance and thickness of yak pericardium were more advantageous than the Australian one. Sichuan yak pericardium and Australian cattle pericardium had comparable performance in shrinkage temperature, mechanical test and anti-calcification test. This study preliminarily verifies the feasibility of substitution of Australian cattle pericardium by Sichuan yak pericardium and promotes the progression of bovine pericardium localization with data support.

    Release date: Export PDF Favorites Scan
  • 动脉化静脉复合组织瓣应对桡动脉掌浅支组织瓣血管变异一例

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content