west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "夏群" 13 results
  • 胃癌脉络膜转移一例

    Release date:2016-09-02 06:03 Export PDF Favorites Scan
  • 暂时性水囊外加压治疗孔源性视网膜脱离

    Release date:2016-09-02 06:05 Export PDF Favorites Scan
  • 双眼急性后极部缺血性视神经病变二例

    Release date:2016-09-02 06:21 Export PDF Favorites Scan
  • DEVELOPMENT RESEARCH OF IN VIVO KINEMATICS IN LUMBAR DEGENERATIVE SPONDYLOLISTHESIS

    ObjectiveTo review the researches of in vivo kinematics in lumbar degenerative spondylol isthesis (DS). MethodsRelated literature concerning the in vivo kinematics in patients with lumbar DS was extensively reviewed and comprehensively analyzed in 4 terms of the instabil ity of lumbar DS, vertebral motion pattern, the morphological changes of spinal canal, and intraoperative biomechanical measurement. ResultsWhether there is lumbar segmental instabil ity in lumbar DS patients is still controversial, which should be based on degenerative stage of lumbar spine and grade of slip. The hypomobility of the lumbar spinous processes and the facet joint is seen in DS. The diameter, cross-sectional area, and volume of spinal canal in lumbar DS patients are significantly smaller than those of the normal control. Because of its invasive procedure and medical ethics, the use of the intraoperative measurement device is limited. These reported researches of in vivo kinematics in DS are almost on the sagittal plane. However, few data have been reported on the 6-degree-of-freedom (6DOF) kinematics of the diseased levels under physiological loading conditions. ConclusionThe 6DOF kinematics data can accurately reflect the segmental motion characteristics in lumbar DS patients, recent studies have been reported, further studies are still needed.

    Release date: Export PDF Favorites Scan
  • 中心性浆液性脉络膜视网膜病变的屈光变化

    null

    Release date:2016-09-02 06:11 Export PDF Favorites Scan
  • 中心性浆液性脉络膜视网膜病变的立体视功能检测

    Release date:2016-09-02 06:11 Export PDF Favorites Scan
  • 中心性浆液脉络膜视网膜病变双眼影像不等的检测

    Release date:2016-09-02 06:21 Export PDF Favorites Scan
  • IN VIVO THREE-DIMENSIONAL TRANSIENT MOTION CHARACTERISTICS OF THE SUBAXIAL CERVICAL SPINE IN HEALTHY ADULTS

    ObjectiveTo observe the in vivo three-dimensional (3-D) transient motion characteristics of the subaxial cervical spine in healthy adults. MethodsSeventeen healthy volunteers without cervical spine related diseases were recruited for this study, including 8 males and 9 females with a mean age of 26 years (range, 23-41 years). The vertebral segment motion of each subject was reconstructed with CT, and Rhinoceros 4.0 solid modeling software were used for 3-D reconstruction model of the subaxial cervical spine. In vivo cervical vertebral motion in flexionextension, left and right bending, left and right rotation was observed with dual fluoroscopic imaging system (DFIS). Coordinate systems were established at the vertebral center of C3-7 to obtain the intervertebral range of motion (ROM) and displacement at C3, 4, C4, 5, C5, 6, and C6, 7. The X-axis pointed to the left along the coronal plane, the Y-axis pointed to the back along the sagittal plane, and the Z-axis perpendicular to the X-Y plane pointed to the head. The ROM along X, Y, and Z axises were represented by rotation in flexion-extension (α), in left-right bending (β), and in left-right twisting (γ) respectively, and the displacement in left-right direction (x), in anterior-posterior direction (y), and in proximaldistal direction (z), respectively. ResultsIn flexion and extension, the displacement in anterior-posterior direction of C6, 7 was significantly less that of other segments (P<0.05), but the displacements in left-right direction and in proximaldistal direction showed no significant difference between segments (P>0.05); the ROM values in flexion-extension of C4, 5 and C5, 6 were significantly larger than those of C3, 4 and C6, 7 (P<0.05), and the ROM value in left-right twisting of C4, 5 was significantly larger than those of C5, 6 and C6, 7 (P<0.05), but the ROM value in left-right bending showed no significant difference between segments (P>0.05). In left and right bending, there was no significant difference in the displacement between other segments (P>0.05) except that the displacement in anterior-posterior direction of C3, 4 was significantly larger than that of C4, 5 (P<0.05), and that the displacement in proximal-distal direction of C6, 7 was significantly less than that of C3, 4 and C4, 5 (P<0.05); no significant difference was shown in the ROM value between segments (P>0.05), except that the ROM value in left-right twisting of C3, 4 was significantly larger than that of C5, 6 and C6, 7 (P<0.05). In left and right rotation, the ROM value in left-right twisting of C3, 4 was significantly larger than that of C4, 5 and C6, 7 (P<0.05), and the displacement and ROM value showed no significant differece between other segments (P>0.05). ConclusionThe intervertebral motions of the cervical spine show different characters at different levels. And the 6-degree-of-freedom data of the cervical vertebrae are obtained, these data may provide new information for the in vivo kinematics of the cervical spine.

    Release date: Export PDF Favorites Scan
  • Vertebral three-dimensional motion characteristics of adjacent segments in patients with isthmic spondylolisthesis in vivo

    ObjectiveTo observe vertebral three-dimensional motion characteristics of adjacent segments in patients with symptomatic L4 isthmic spondylolisthesis (IS). MethodsFourteen symptomatic L4 IS patients who underwent surgery treatment (trial group) and 15 asymptomatic volunteers without back pain and other lesions of spine (control group) were recruited. There was no significant difference in gender, age, body mass index, and bone mineral density between the two groups (P>0.05). The three-dimensional reconstruction model of lumbar spine was acquired from the thin slice CT of the lumbar spine of the subjects by combining dual-X-ray fluoroscopy imaging system with spiral CT examination. The model was matched to the double oblique X-ray fluoroscopy images captured by dual-X-ray fluoroscopy imaging system at different active positions of the lumbar spine to reproduce the three-dimensional instantaneous of lumbar spondylolisthesis at different state of motion. The motion and relative displacement of adjacent segments (L3, 4 and L5, S1) of spondylolisthesis were measured quantitatively by establishing a three-dimensional coordinate system at the geometric center of the vertebral body. The results were compared with those of the control group. ResultsWhen L3, 4 in the control group were flexed flexion-extension, left-right twisting, and left-right bending, and when L5, S1 in the control group were flexed left-right twisting and left-right bending, the activity along the main axis of motion (main axis of motion) tended to increase compared with that along the corresponding coupled axis of motion (secondary axis of motion); however, this trend disappeared in the trial group, and the main and secondary movements were disordered. Because of the coronal orientation of the facet joints of L5, S1, the degree of motion along the main axis of motion decreased during flexion and extension, but this trend disappeared in the trial group. Compared with the control group, L3, 4 in the trial group exhibited displacement instability in flexion-extension, left-right twisting, and left-right bending (P<0.05); there was no significant difference in the relative displacement of L5, S1 intervertebral bodies along x, y, and z axes between the trial group and the control group in flexion-extension, left-right twisting, and left-right bending curvature (P>0.05). ConclusionPatients with symptomatic L4 IS have disorders of primary and secondary movement patterns in adjacent segments, while IS showed significantly displacement instability in L3, 4 and significantly decreased motion in L5, S1.

    Release date:2018-12-04 03:41 Export PDF Favorites Scan
  • FABRICATION AND ANALYSIS OF A NOVEL TISSUE ENGINEERED COMPOSITE BIPHASIC SCAFFOLD FOR ANNULUS FIBROSUS AND NUCLEUS PULPOSUS

    Objective To fabricate a novel composite scaffold with acellular demineralized bone matrix/acellular nucleus pulposus matrix and to verify the feasibility of using it as a scaffold for intervertebral disc tissue engineering through detecting physical and chemical properties. Methods Pig proximal femoral cancellous bone rings (10 mm in external diameter, 5 mm in internal diameter, and 3 mm in thickness) were fabricated, and were dealed with degreasing, decalcification, and decellularization to prepare the annulus fibrosus phase of scaffold. Nucleus pulposus was taken from pig tails, decellularized with Triton X-100 and deoxycholic acid, crushed and centrifugalized to prepare nucleus pulposus extracellular mtrtix which was injected into the center of annulus fibrosus phase. Then the composite scaffold was freeze-dryed, cross-linked with ultraviolet radiation/carbodiimide and disinfected for use. The scaffold was investigated by general observation, HE staining, and scanning electron microscopy, as well as porosity measurement, water absorption rate, and compressive elastic modulus. Adipose-derived stem cells (ADSCs) were cultured with different concentrations of scaffold extract (25%, 50%, and 100%) to assess cytotoxicity of the scaffold. The cell viability of ADSCs seeded on the scaffold was detected by Live/Dead staining. Results The scaffold was white by general observation. The HE staining revealed that there was no cell fragments on the scaffold, and the dye homogeneously distributed. The scanning electron microscopy showed that the pore of the annulus fibrosus phase interconnected and the pore size was uniform; acellular nucleus pulposus matrix microfilament interconnected forming a uniform network structure, and the junction of the scaffold was closely connected. The novel porous scaffold had a good pore interconnectivity with (343.00 ± 88.25) µm pore diameter of the annulus fibrosus phase, 82.98% ± 7.02% porosity and 621.53% ± 53.31% water absorption rate. The biomechanical test showed that the compressive modulus of elasticity was (89.07 ± 8.73) kPa. The MTT test indicated that scaffold extract had no influence on cell proliferation. Live/Dead staining showed that ADSCs had a good proliferation on the scaffold and there was no dead cell. Conclusion Novel composite scaffold made of acellular demineralized bone matrix/acellular nucleus pulposus matrix has good pore diameter and porosity, biomechanical properties close to natural intervertebral disc, non-toxicity, and good biocompatibility, so it is a suitable scaffold for intervertebral disc tissue engineering.

    Release date:2016-08-31 04:07 Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content