west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "小主动脉根部" 3 results
  • 再次双瓣膜置换联合主动脉幕帘重建术一例

    Release date:2019-12-13 03:50 Export PDF Favorites Scan
  • Bentall procedure for reoperation in the small aortic root or annulus

    ObjectiveTo investigate and evaluate the safety and efficacy of Bentall operation in the reoperation of patients with small aortic root or annulus.MethodsBentall procedure was performed in 24 patients with small aortic root or annulus in our hospital from September 2014 to December 2019. There were 18 males and 6 females with a mean age of 31-68 (45.70±15.27) years. All patients had undergone a previous replacement of the aortic valve including 20 patients receiving valve replacement, 2 patients aortic root replacement with a valved conduit and 2 patients bioprothesis replacement.ResultsThere was no early death in hospital and one death during the 30-day postoperative period. Re-thoracotomy due to bleeding was necessary in only 2 patients and no bleeding was related to the proximal anastomosis of the conduit. One patient performed pacemaker implantation for heart block after the procedure. The mean sizes of implanted aortic valve prosthesis were 22.75±1.78 mm. A mean gradient across the aortic valve prostheses in the postoperative echocardiographic examination was 11.17±2.24 mm Hg.ConclusionBentall procedure is safe and allows a larger size of prosthesis implantation in patients with small aortic annulus or root after previous aortic valve or complete root replacement, resulting in good postoperative hemodynamic characteristics and short-term clinical results.

    Release date: Export PDF Favorites Scan
  • Aortic-mitral annular enlargement technique in re-valve surgery: A retrospective study in a single center

    Objective To investigate and evaluate the safety and efficacy of the aortic-mitral annular enlargement technique (double annular enlargement) in patients with small-size valve prostheses after prior valve surgery. MethodsThe clinical data of patients who underwent double valve annular enlargement in Wuhan Asia Heart Hospital from April 2020 to April 2022 were retrospectively analyzed. Results A total of 30 patients were collected, including 2 males and 28 females aged 9-78 (52.71±3.53) years. All patients had previous heart valve surgery, including 1 patient receiving the third heart surgery. All patients were operated on successfully and there were no postoperative in-hospital deaths. There was no postoperative bleeding which needed a secondary open-chest hemostasis, and one patient underwent permanent pacemaker implantation due to postoperative sick sinus syndrome. The mean diameter of the implanted prosthetic aortic valve was 24.23±1.60 mm, which was significantly larger than that of the preoperative aortic valve (21.03±1.90 mm, P<0.001). The mean diameter of the implanted prosthetic mitral valve was 28.33±1.21 mm, which was significantly larger than that of the preoperative mitral valve (25.43±0.84 mm, P<0.001). The mean peak gradient difference across the prosthetic aortic valve on postoperative echocardiography was 18.17±6.44 mm Hg, which was significantly lower than that of the preoperative aortic valve (82.57±24.48 mm Hg, P<0.001). The mean peak gradient difference of the postoperative prosthetic mitral valve was 12.73±5.45 mm Hg, which was significantly lower than that of the preoperative mitral valve (19.43±8.97 mm Hg, P=0.003). Conclusion The double annular enlargement technique is safe and effective for reoperation in patients with a history of valve surgery with a small aortic root to obtain both a larger size prosthetic valve for a larger orifice area and stability of the mitral-aortic valve union, resulting in good postoperative hemodynamic characteristics and clinical outcomes.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content