find Author "尹庆水" 13 results
  • CLASSIFICATION OF ATLAS PEDICLES AND METHODOLOGICAL STUDY OF PEDICLE SCREW FIXATION

    Objective To investigate the classification of atlas pedicles and the methods of the pedicle screw fixation. Methods To study the classification of atlas pedicles, 48 dry adult atlas specimens were measured. By atlas 3D-CT reconstruction, two transverse sections were establ ished by going through the one third of the lateral atlas pedicle and 2 mmbelow the vertebral artery sulcus. By setting 3.50 mm and 1.75 mm as the standardized diameter and radius for the screwand according to the thickness of bone substance of vertebral artery sulcus that went through the one third of the lateralatlas pedicle, the anatomical morphology of atlas pedicles were classified into three types: general type with 40 specimens (83%), l ight variation type with 6 specimens (13%), and severe variation type with 2 specimens (4%). The entry pathway was confirmed by the intersection l ine of the two transverse sections that went through the lateral one third of the atlas pedicle and 2 mm below the vertebral artery sulcus. The project-point of the entry pathway on the atlas posterior arch was considered to be the entry point. Forty-eight dry atlas specimens were used to measure the following relevant anatomic data with an electronic cal iper: the distance between the entry point and the posterior margin of the lateral mass (L1), the height of atlas pedicle at the entry point (L2), the vertical distance between the entry point and the inferior articular facet of the lateral mass (L3), the mass height at the entry point (L4), the mass width at the entry point (L5), the width of the atlas pedicle at the entry point (L6), the thickness of the pedicle under the vertebral artery sulcus at the entry pathway (H1). To research the method of the pedicle screw fixation, 12 fresh-frozen adult atlas specimens were adopted to simulate the fixation of the pedicle screw. The thickness of the bone substance of vertebral artery sulcus on both the left and the right sides of the pathway was grinded into 3 types: 1.5 mm and 2.5 mm, 1.5 mm and 4.0 mm, 2.5 mm and 4.0 mm, and each type had four specimens. The entry pathway was confirmed by the intersection l ine of two transverse sections that went through the lateral one third of atlas pedicle and 2 mm below the vertebral artery sulcus. Results On the left side, L1 was (5.79 ± 1.24) mm, L2 (4.55 ± 1.29) mm, L3 (5.12 ± 1.06) mm, L4 (12.43 ± 1.01) mm, L5 (12.66 ± 1.37) mm, L6 (7.86 ± 0.77) mm, and H1 (4.11 ± 1.25) mm. On the right side, L1 was (5.81 ± 1.26) mm, L2 (4.49 ± 1.22) mm, L3 (5.15 ± 1.05) mm, L4 (12.49 ± 0.98) mm, L5 (12.65 ± 1.38) mm, L6 (7.84 ± 0.78) mm, and H1 (4.13 ± 1.29) mm. There was no significant difference between the two sides (P gt; 0.05). After simulation of inserting screws, no screw in the specimens was found to break the bone substance in the sulcus of vertebral artery. Conclusion For the pedicle screw fixation of those patients whose atlas posterior arches are not high enough, we might partly drill through or beyond the atlas posterior arch. The entry point should be ascertained by preoperative 3D-CT reconstruction and intra-operative exploration.

    Release date:2016-09-01 09:16 Export PDF Favorites Scan
  • RECENT DEVELOPMENT OF COMPUTER-AIDED TISSUE ENGINEERING

    Objective To introduce the recent advances of the application of computer technology in tissue engineering. Methods The recent original articlesrelated to computer technology, medical image technology, computer-aided design, the advanced manufacture technology were summarized and systematically analyzed.Results Computer-aided tissue engineering is a new fieldon tissue engineering. It is the future direction of tissue engineering study. This article reviews recent development of medical CT/MRI scanning, three-dimensional reconstruction, anatomical modeling, computeraided design, computer-aided manufacturing, rapid prototyping, RP manufacturing of tissue engineering scaffolds and computeraided implantation.Conclusion Computer-aided tissue engineering can be used in scaffolds design and fabrication, computer-aided artificial tissue implantation. It is a new field on tissue engineering. 

    Release date:2016-09-01 09:26 Export PDF Favorites Scan
  • LONG-TERM FOLLOW-UP STUDY ON EXPANDABLE Cage IN TREATMENT OF DEGENERATIVE LUMBAR DISEASE

    ObjectiveTo explore the long-term effectiveness of expandable Cage in treatment of degenerative lumbar disease. MethodsBetween January 2005 and January 2008, 72 patients with degenerative lumbar disease were treated by expandable Cage and followed up for 5 years. Of 72 cases, 41 were male and 31 were female with an average age of 40.5 years (mean, 35-65 years), including 35 cases of lumbar spinal stenosis, 20 cases of degenerative lumbar instability, and 17 cases of serious lumbar intervertebral disc protrusion combined with lumbar instability. The disease duration was 6-28 months (mean, 9 months). The affected lumbar segments were L3, 4 in 6 patients, L4, 5 in 37 patients, and L5, S1 in 29 patients. The Oswestry disability index (ODI) was used to evaluate the effectiveness before and after operation and to calculate the improvement rate. During the follow-up, the anteroposterior, lateral, and dynamic X-ray films were taken to evaluate the operated segment fusion rate. The intervertebral lordosis angle was measured, and adjacent segment degeneration was observed. ResultsThe operation time was 35-90 minutes (mean, 65 minutes); the intraoperative blood loss was 200-450 mL (mean, 280 mL), and all the patients received intraoperative autologous blood transfusion; the postoperative bedridden time was 3-7 days (mean, 4.5 days); the hospitalization days were 10-18 days (mean, 12 days). No complications of nerve root injury, cauda equina injury, or cerebrospinal fluid leakage occurred during operation. All patients achieved primary healing of the incisions. All 72 patients were followed up for 5 years. At 3 months, 1 year, and 5 years after operation, the ODI were 8.2±2.6, 6.9±1.9, and 6.4±1.3 respectively, showing significant differences when compared with preoperative value (41.5±3.5) (P<0.05); the improvement rates were 87.3%±1.2%, 90.1%±0.8%, and 91.6%±1.3% respectively, showing no significant difference (F=0.492, P=0.375); the intervertebral lordosis angles were (5.1±1.2), (5.0±0.5), and (5.4±0.8)°respectively, showing no significant difference (F=0.570, P=0.453). At 5 years after operation, the intervertebral fusion rate was 100%, with no adjacent segment degeneration. ConclusionUsing expandable Cage to treat degenerative lumbar disease can get stabilization without pedicle screw fixation, the good effectiveness is shown after long-term follow-up.

    Release date: Export PDF Favorites Scan
  • DOUBLE VOLUME INTERNAL FIXATION FOR CORRECTION OF ADULT POST-TRAUMATIC CUBITUS VARUS

    Objective Supracondylar closing wedge osteotomy is a standard operation for the management of post-traumatic cubitus varus deformity. There are many fixation methods for the broken ends of bone. However, most of these fixation methods are fraught with various complications. To evaluate the methods and functional results of double volume internal fixation for correction of adult post-traumatic cubitus varus deformity. Methods The cl inical data were retrospectively reviewed, from 22 cases of adults post-traumatic cubitus varus deformity between June 2007 and December 2010.There were 16 males and 6 females, aged 18-29 years (mean, 21 years) and they all had a history of supracondylar fracture. The deformities of cubitus varus appeared at 6 months (range, 3 months to 1 year) after fracture, and the operations were carried out at 4-17 years (mean, 8 years) after deformity occurrence. The valgus angle were 16-25° (mean, 20.6°) and the Flynn functional scores were all poor before operation. Supracondylar closing wedge osteotomies were performed. Two reconstruction plates were moulded and placed to the media and lateral volumes of the humerus to fix the broken ends of the osteotomy surfaces. External fixation was not needed and early rehabil itation was performed postoperatively in all cases. Results Incisions healed by first intention. All cases were followed up 6 to 24 months (mean, 13 months). At last follow-up, the valgus angle was 0-10° (mean, 7.5°). All cases got bone union at 8-13 weeks (mean, 10 weeks) after operation. No related complications occurred, such as infection, nervous or vein injury, and loosening or breakage of internal fixator; and no cubitus varus recurred. The Flynn scores were excellent in 17 cases, good in 3 cases, and fair in 2 cases; the excellent and good rate was 91%. Conclusion The operation of supracondylar osteotomy with double plates internal fixation for the correction of adult post-traumatic cubitus varus deformity can rigidly stabil ize distal humerus, which is helpful to functional training just after operation and satisfactory restoration of the elbow function.

    Release date:2016-08-31 04:23 Export PDF Favorites Scan
  • 寰枢椎前、后路固定对枢椎及齿突拉力的比较研究

    目的 比较前路经口寰枢椎复位钢板(transoral atlantoaxial reduction plate,TARP)系统与后路寰枢椎椎弓根钉棒系统对枢椎及齿突的最大下位力,为临床选择固定方式提供实验依据。 方法 取6 个男性新鲜尸体寰枢椎标本(C1、2)制备寰枢椎不稳模型后,分别采用TARP 系统(TARP 组)和寰枢椎椎弓根钉棒系统(椎弓钉棒组)固定,采用材料试验机测量前、后路固定系统对枢椎及齿突的最大下拉力。 结果 TARP 组和椎弓根钉棒组最大下拉力分别为(77.38 ± 16.10)N 和(39.31 ± 17.27)N,两组比较差异有统计学意义(t=17.106,P=0.000)。 结论 前路固定系统较后路固定系统对枢椎及齿突下拉力大,提示对于难复性寰枢椎脱位,从前路进行复位具有更可靠的复位效能。

    Release date:2016-08-31 04:23 Export PDF Favorites Scan
  • 棘突椎板回植内固定术重建腰椎后柱结构的早期临床研究

    目的 总结棘突椎板原位回植内固定术在重建腰椎后柱结构中的应用价值及早期临床疗效。 方法 2008 年1 月- 2010 年8 月,对28 例行腰椎后路棘突椎板完整截骨手术的患者,采用原位回植联合钢板螺钉内固定方法重建腰椎后柱结构。其中男18 例,女10 例;年龄4 ~ 41 岁,中位年龄13 岁。腰椎管内占位性病变5 例,痉挛性脑瘫23 例。术中采用微型钛板内固定24 例,椎板交叉螺钉内固定4 例;行单个棘突椎板回植13 例,2 个棘突椎板回植12 例,3 个棘突椎板回植2 例,4 个棘突椎板回植1 例。 结果 术后出现脑脊液漏3 例,其中合并低颅压性头痛2 例,均经对症治疗后治愈。所有切口均Ⅰ期愈合。28 例均获随访,随访时间6 ~ 36 个月,平均18.3 个月。术后3 个月复查动力位X 线片未见腰椎失稳表现;CT 示所有患者椎板均骨性融合,椎管形态恢复正常,未见椎板移位、椎管狭窄及硬膜囊受压,未见瘢痕及骨痂长入椎管内,无继发神经受压表现。 结论 棘突椎板回植内固定术可重建腰椎后柱结构,固定可靠,能有效预防术后椎管内瘢痕粘连和脊柱失稳等并发症。

    Release date:2016-08-31 05:42 Export PDF Favorites Scan
  • CLINICAL ANALYSIS OF TREATING 164 CASES OF TENDON AND LIGAMENT INJURIES WITH ALLOGRAFT TENDON

    To research the operative method and the cl inical efficacy of repairing and reconstructing tendon and l igament with allograft tendon. Methods From September 2000 to May 2007, 164 cases with tendon and l igament injuries were treated, including 116 males and 48 females aged 21-47 years old (average 31.5 years old). There were 126 cases of anterior cruciate l igament injury, 18 cases of complete acromioclavicular dislocation, 10 cases of old dislocation of radialhead, 4 cases of Achilles tendon rupture, 2 cases of tibial is anterior muscle rupture, 2 cases of patellar tendon rupture, and 2 cases of rectus femoris rupture. Time interval between injury and hospital admission was 4-345 days (average 75 days). Allograft tendon 10-26 cm in length with suture anchor or absorbable interference screw was used to reconstruct the l igament and tendon. Results All wounds healed by first intention, except one case of rectus femoris rupture. All patients were followed for 10-36 months (average 21 months). The international knee documentation commitee and the Lysholm score of patients with anterior cruciate l igament injury 12 months after operation were significantly higher than that of before operation (P lt; 0.01). According to the Lazzcano and Karlsson score standard, 13 cases of complete acromioclavicular dislocation at 10-12 months after operation were graded as excellent and 5 cases were good. According to Arner Lindholm score standard, 3 cases of Achilles tendon rupture at 8-16 months after operation were graded as excellent and 1 case was good. For the patients with tibial is anterior muscle rupture, at 10-17 months after operation, the limitation of dorsal extension in ankle joint was 5°, and the muscle strength in the anterior tibial is muscle was decreased. For the patients with patellar tendon rupture, one completely restored the motion range of the knee joint 14 months after operation, the other had knee extension l imitation of 10° at 13 months after operation. For the patients with rectus femoris rupture, one had 15° of extension limitation at 18 months after operation, the other suffered limitation of both extension and genuflex at 12 months after operation. According to the Broberg-Morrey score standard, 7 caseswith old dislocation of radial head were graded as excellent and 3 cases were good at 3-36 months after operation. Conclusion Allograft tendon is a good material for repairing and reconstructing tendon and ligament injuries, but attention should be paid to postoperatively early exercise under appropriate protection and early management of local rejection.

    Release date:2016-09-01 09:07 Export PDF Favorites Scan
  • An observation on risk of infection in treatment of craniovertebral junction disorders by transoral approach operation

    ObjectiveTo study the changes of bacterial flora after a series of preoperative oral disinfection and the postoperative recovery of patients with craniovertebral junction disorders who were treated with transoral approach operations. And to provide a theoretical basis for the prevention of postoperative complications such as infection.MethodsThe clinical data of 20 cases with craniovertebral junction disorders and treated with transoral approach operations between October 2009 and May 2010 were analyzed. There were 8 males and 12 females, aged 2-66 years (median, 34.5 years). According to the classification of American Spinal Injury Association (ASIA), there were 4 cases of grade B, 8 of grade C, 6 of grade D, and 2 of grade E. The Japanese Orthopedic Association (JOA) score was 10.3±3.0. The mucosa samples of the posterior pharyngeal wall were sent for bacteria culture. These samples were collected by sterile cotton swabs at four crucial points including 3 days before operation/before gargling (T1), 3 days after continuous gargling by chlorhexidine acetate/after anesthesia intubation on the day of operation (T2), after intraoperative cleaning and washing of the mouth (T3), and after intraoperative iodophor immersion for 5-10 minutes (T4). The microflora was stained by means of smear and further counted after an investigation by microscope. The ASIA classification and the JOA scores were applied to evaluate the postoperative nerve function of the patients. A regular reexamination of cervical vertebra with X-ray film, CT, and MRI was conducted after operation to evaluate the reduction of atlantoaxial dislocation, internal fixation position, bone graft fusion, inflammatory lesion, and tumor resection in the craniovertebral junction.ResultsAfter a series of oral disinfection, the mucosa of the posterior pharyngeal wall of all the patients was in a sterile state, which was considered as type Ⅰ incision. All these 20 patients were treated with successful operations, without any intraoperative injury in vertebral artery and spinal cord, or any postoperative complications such as plate loosening, incision infection, or intracranial infection. All the patients were followed up 3-23 months, with an average of 5.15 months. The symptoms such as neck pain, limb numbness and weakness, neural symptoms, etc. were improved to different degrees after operation. The JOA score was improved to 13.4±1.9 at 3 months after operation, showing significant difference when compared with preoperative score (t=8.677, P=0.000); and the atlantoaxial joints had been fused. At last follow-up, the ASIA grades were improved when compared with those before operation. ConclusionIt is safe and effective to cut the posterior pharyngeal muscle layer and implant internal fixation by means of transoral approach in the treatment of craniovertebral junction disorders.

    Release date:2020-07-07 07:58 Export PDF Favorites Scan
  • BIOCOMPATIBILITY OF SILICON CONTAINING MICRO-ARC OXIDATION COATED MAGNESIUM ALLOY ZK60 WITH OSTEOBLASTS CULTURED IN VITRO

    Objective To research in vitro biocompatibility of silicon containing micro-arc oxidation (MAO) coated magnesium alloy ZK60 with osteoblasts. Methods The surface microstructure of silicon containing MAO coated magnesium alloy ZK60 was observed by a scanning electron microscopy (SEM), and chemical composition of the coating surface was determined by energy dispersive spectrum analysis. The experiments were divided into 4 groups: silicon containing MAO coated magnesium alloy ZK60 group (group A), uncoated magnesium alloy ZK60 group (group B), titanium alloy group (group C), and negative control group (group D). Extracts were prepared respectively with the surface area to extraction medium ratio (1.25 cm2/ mL) according to ISO 10993-12 standard in groups A, B, and C, and were used to culture osteoblasts MC3T3-E1. The α-MEM medium supplemented with 10% fetal bovine serum was used as negative control in group D. The cell morphology was observed by inverted phase contrast microscopy. MTT assay was used to determine the cell viability. The activity of alkaline phosphatase (ALP) was detected. Cell attachment morphology on the surface of different samples was observed by SEM. The capability of protein adsorption of the coating surface was assayed, then DAPI and calcein-AM/ethidium homodimer 1 (calcein-AM/EthD-1) staining were carried out to observe cell adhesion and growth status. Results The surface characterization showed a rough and porous layer with major composition of Mg, O, and Si on the surface of silicon containing MAO coated magnesium alloy ZK60 by SEM. After cultured with the extract, cells grew well and presented good shape in all groups by inverted phase contrast microscopy, group A was even better than the other groups. At 5 days, MTT assay showed that group A presented a higher cell proliferation than the other groups (P lt; 0.05). Osteoblasts in groups A and C presented a better cell extension than group B under SEM, and group A exhibited better cell adhesion and affinity. Protein adsorption in group A [ (152.7 ± 6.3) µg/mL] was significantly higher than that of group B [(96.3 ± 3.9) µg/mL] and group C [ (96.1 ± 8.7) µg/mL] (P lt; 0.05). At each time point, the adherent cells on the sample surface of group A were significantly more than those of groups B and C (P lt; 0.05). The calcein-AM/EthD-1 staining showed that groups A and C presented better cell adhesion and growth status than group B. The ALP activities in groups A and B were 15.55 ± 0.29 and 13.75 ± 0.44 respectively, which were significantly higher than those in group C (10.43 ± 0.79) and group D (10.73 ± 0.47) (P lt; 0.05), and group A was significantly higher than group B (P lt; 0.05). Conclusion The silicon containing MAO coated magnesium alloy ZK60 has obvious promoting effects on the proliferation, adhesion, and differentiation of osteoblasts, showing a good biocompatibility, so it might be an ideal surface modification method on magnesium alloys.

    Release date:2016-08-31 04:07 Export PDF Favorites Scan
  • COMPUTER AID DESIGNED OPERATION OF COMPLICATED CALCANEAL FRACTURE BY 3D SIMULATION TECHNIQUE

    Objective To precisely treat compl icated calcaneal fracture by 3D simulation through computer aid designed operation. Methods From November 2007 to March 2008, 38 patients of calcaneal fracture were treated. There were 29 males and 9 females aged 14-69 years old (average 29.8 years old). According to Sanders classification, there were 4 patients oftype I, 14 of type II, 12 of type III, and 8 of type IV. The time between injury and surgery was 3 hours to 5 days. The CT images of calcaneal fracture of 38 patients were put into computer for 3D reconstruction, then the Bouml;hler angles were measured and bone grafting angles were designed. According to the angle surveyed by the computer, the individual-oriented operation program was made, and then the operation was done under C-arm X-ray machine. Results The preoperative Bouml;hler angel was (34.58 ± 4.38)° in the normal side and (8.33 ± 12.62)° in the injured side, indicating there was significant difference (P lt; 0.05). During the process of the poking reduction by 3D simulation, when the bone rotating angle was (28.84 ± 6.51)°, the Bouml;hler angel was restored to (32.86 ± 1.72)°, indicating there was no significant difference when compared with the normal side before operation (P gt; 0.05), and significant difference compared with the injured side before operation (P lt; 0.05). Twenty-eight patients were followed up for 12-22 months (average 18 months). The Bouml;hler angel was restored to (32.41 ± 1.42)° 1 year after operation. According to the foot function scoring system made by American Ankle Surgery Association, 16 cases were graded as excellent, 10 as good, 1 as fair, 1 as poor, and the excellent and good rate was 92.9%. Conclusion Computer aid designed operation of compl icated calcaneal fracture by 3D simulation technique can restore the Bouml;hler angel and subtalar joint precisely. It is aneffective supplementary treatment method for calcaneal fracture.

    Release date:2016-09-01 09:08 Export PDF Favorites Scan