west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "戴惟葭" 4 results
  • Changes of retinal nerve fiber layer thickness and its correlation with visual field mean defects in early Parkinson′s disease

      Objective To observe the changes of retinal nerve fiber layer (RNFL) thickness and its correlation with visual field mean defects(MD)in Parkinsonprime;s disease (PD).Methods Fifteen eyes of 15 PD patients in early stage and 18 eyes of 18 normal controls undertook RNFL examination by Stratus OCT3. Circular scans (diameter is 3.46 mm) were taken around the optic nerve head including eight quadrants (superior, inferior, temporal, nasal, temporalsuperior, temporalinferior, nasalsuperior and nasalinferior). The RNFL thickness in different quadrants in the two groups was analyzed. The visual field of PD patients was measured by central 302 program of Humphery750 visual field analyzer, and the MD was recorded. The correlation between RNFL thickness and MD was analyzed by linear correlation and regression analysis.Results RNFL thicknesses of superior, inferior, temporal, nasal, temporalsuperior, temporalinferior, nasalsuperior, nasalinferior and average RNFL thickness in the control group were (132.7plusmn;17.4), (141.5plusmn;15.3) ,(83.2plusmn;17.5), (83.7plusmn;22.3) ,(120.8plusmn;21.2), (117.9plusmn;24.5) ,(109.6plusmn;20.6),(110.2plusmn;27.7), and(109.9plusmn;8.5)mu;m respectively, while in the PD group they were (128.1plusmn;25.3) , (128.6plusmn;13.2) , (68.7plusmn;13.5) , (76.5plusmn;17.8) ,(102.6plusmn;23.7), (103.3plusmn;14.1) ,(101.2plusmn;20.9),(96.6plusmn;15.0),(102.3plusmn;11.9) mu;m. Compared with each other, the differences of RNFL thickness of inferior, temporal, temporalsuperior, temporalinferior and average RNFL thickness were statistically significant(t=2.595,2.700,2.330,2.153,2.131;P=0.014,0.011,0.026,0.040,0.041). There was a close negative relationship between average RNFL thickness and MD in PD patients (r=-0.933,P<0.0001). Conclusions RNFL thickness was significantly thinner in PD patients than that in the normal controls. There was a negative relationship between RNFL thickness and MD in PD patients.

    Release date:2016-09-02 05:41 Export PDF Favorites Scan
  • Visual field analysis in early mild Parkinson's disease

    ObjectiveTo evaluate visual field changes in early mild Parkinson's disease. Methods A total of 66 eyes of 33 cases with early mild Parkinson's disease and 72 eyes of 36 age-matched normal individuals were enrolled into the study. Humphrey Field Analyzer II was applied for central visual field test. The visual field indices of mean deviation (MD) and pattern standard deviation (PSD) were analyzed to evaluate the location and the characteristics of visual field defect in this study. ResultsVisual field indices MD (-3.4±2.5) dB was significantly changed in patients with PD when compared to the controls (-0.6±1.7) dB. PSD (4.3±2.6) was significantly higher in patients with PD than that in the control group (2.1±1.8) dB. Glaucoma hemifield test (GHT) assessment was within normal limits in the controls. Of the 33 patients (66 eyes) in PD, GHT showed outside normal limits in 31 eyes, borderline in 8 eyes, and within normal limits in 27 eyes. 31 eyes outside normal limits appeared glaucomatous visual field defects, in which 16 with nasal step and 5 with arcuate defect. ConclusionsVisual field indices including MD and PSD in early mild patients with PD were significantly worse than that in the controls group. GHT abnormalities could be found in early mild PD patients with visual field defects, including pericentral scotoma and nasal step, which mimicked glaucomatous changes.

    Release date: Export PDF Favorites Scan
  • Quantitative analysis of macular retinal thickness and volume in patients with different degrees of Parkinson’s disease

    ObjectiveTo observe the macular retinal thickness and volume in patients with different degrees of Parkinson's disease (PD).MethodsThirty eyes of 30 patients with primary PD and 20 eyes of 20 healthy subjects (control group) in Xuanwu Hospital of Capital Medical University from October 2016 to October 2017 were enrolled in this study. There were 17 males and 13 females, with the mean age of 63.2±6.4 years and disease course of 3.9±2.4 years. The patients were divided into mild to moderate PD group (15 eyes of 15 patients) and severe PD group (15 eyes of 15 patients). The macular area was automatically divided into 3 concentric circles by software, which were foveal area with a diameter of 1 mm (inner ring), middle ring of 1 to 3 mm, and outer ring of 3 to 6 mm. The middle and outer ring were divided into 4 quadrants by 2 radiations, respectively. The changes of retinal thickness and macular volume of the macular center and its surrounding quadrants were analyzed. SPSS 16.0 software was used for statistical analysis. One-way ANOVA were used to analyze all data.ResultsCompared with the control group, the retinal thickness and volume in macular center and each quadrant of the mild to moderate PD group and severe PD group were reduced. Compared with the mild to moderate PD group, the retinal thickness and volume in macular center and each quadrant of the severe PD group were reduced. The differences of retinal thickness and macular volume among 3 groups were significant (F=5.794, 5.221, 5.586, 5.302, 5.926, 5.319, 5.404, 5.261, 5.603; P=0.001, 0.007, 0.003, 0.005, 0.000, 0.004, 0.004, 0.006, 0.002). In inner ring of the mild to moderate PD group and the severe PD group, the retinal thickness and macular volume in the upper and the nasal were the largest, the inferior was followed, and the temporal was the smallest. In outer ring of the mild to moderate PD group and the severe PD group, the retinal thickness and macular volume in the nasal was the largest, the upper was the second, the temporal and the inferior were the smallest.ConclusionsThe retinal thickness and volume of the macular central fovea and its surrounding areas in PD patients are significantly thinner than that in the healthy subjects. And with the increase of the severity of PD, the macular structure changes obviously, showing macular center and its surrounding macular degeneration thin, macular volume reduced.

    Release date:2019-05-17 04:15 Export PDF Favorites Scan
  • Quantitative analysis of optic disc structure and retinal nerve fiber layer thickness in patients with different degrees of Parkinson's disease

    ObjectiveTo observe the changes of optic disc structure and retinal nerve fiber layer thickness (RNFL) in patients with different degrees of Parkinson's disease (PD).MethodsThirty eyes of 30 patients with primary PD and 20 eyes of 20 healthy subjects (control group) in Xuanwu Hospital of Capital Medical University from October 2016 to October 2017 were enrolled in this study. The patients were divided into mild to moderate PD group (15 eyes of 15 patients) and severe PD group (15 eyes of 15 patients). All the patients underwent OCT examination. The optic disc area, cup area, C/D area ratio, rim volume, disc volume, cup volume, rim area, C/D area, linear C/D, vertical C/D, the thickness of average RNFL, superior, inferior, temporal upper (TU), superior temporal (ST), superior nasal (SN), nasal upper (NU), nasal lower (NL), inferior nasal (IN), inferior temporal (IT), temporal lower (TL) quadrant RNFL thickness. Analysis of variance was performed for comparison among three groups. Minimum significant difference t test was performed for comparison between two groups.ResultsOptic disc structure parameters: there was no significant difference in the area of optic disc between the three groups (F=1.226, P>0.05). The other optic disc parameters were significantly different in the three groups (F=5.221, 5.586, 6.302, 5.926, 5.319, 5.404, 5.861, 6.603; P<0.05). The cup area, cup volume, C/D area, linear C/D, vertical C/D of the mild to moderate PD group and severe PD group were higher than that of the control group (P<0.05). The cup area, cup volume, C/D area, linear C/D, vertical C/D of the severe PD group were higher than those of mild to moderate PD group (P<0.05), the rim area, rim volume and disc volume of the severe PD group were smaller than that of mild to moderate PD group (P<0.05). The thickness of RNFL: there was no significant difference between the three groups of ST, SN, NU and NL (F=3.586, 2.852, 2.961, 2.404; P>0.05). The average thickness of RNFL, TU, IN, IT and TL in patients of the mild to moderate PD group and severe PD group were less than that in the control group (P<0.05). The thickness of the average RNFL, TU, IN, IT and TL in patients of the severe PD group were less than that in the mild to moderate PD group (P<0.05). With the increase of PD severity, the RNFL of TL and TU thinned most significantly.ConclusionsWith the increase of the severity of PD, the optic disc structure and RNFL thickness changes obviously, showing reduced optic disc area and volume, enlarged cup area and volume significantly enlarged C/D ratio. The average RNFL thickness of PD patients is significantly thinner than that of the controls, and it is the most obvious in the TU and TL quadrant.

    Release date:2020-02-18 09:28 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content