  • A Clinical Study about 99Tcm-Tetrofosmin Imaging in Detection of Suspicious Palpable Breast Lesions

    【Abstract】Objective To assess the value of 99Tcm-tetrofosmin imaging in discriminating malignant mass from benign breast mass.Methods From June 2000 to January 2002, 104 patients with breast mass detected by clinical examination were included. After 740 MBq 99Tcm-tetrofosmin was injected intravenously in the contralateral arm to the breast lesion, the front and the lateral images were collected in 5 min, 10 min and 20 min respectively. 99Tcm-tetrofosmin imaging localized in breast was defined as the positive sign of affinitive tumor. All patients underwent operation within one week. Using histological assessment as a golden standard, the sensitivity, specificity, positive and negative predictive value for 99Tcm-tetrofosmin SPECT of the breast were calculated respectively. Results The sensitivity of 99Tcm-tetrofosmin imaging for discriminating between malignant mass and benign mass in palpable breast lesions was 87%, specificity 84%, positive and negative predictive value were 85% and 86% respectively. Conclusion The results suggested that 99Tcm-tetrofosmin imaging is a valuable tool for distinguishing between malignant mass and benign mass in palpable breast lesions.

    Release date:2016-08-28 04:28 Export PDF Favorites Scan
  • Clinical Application of 99Tcm-Octreotide and 99Tcm-MIBI Imaging in the Diagnosis of Breast Cancer

    Objective To evaluate the value of 99Tcm-Octreotide somatostatin receptor and 99Tcm-MIBI imaging in the detection of breast cancer. Methods 99Tcm-Octreotide and 99Tcm-MIBI imaging were performed in 26 patients with breast masses before operation. The scintigraphy results were analysed compared with pathologic study. Results The sensitivity, specificity and accuracy of 99Tcm-Octreotide scintigraphy for breast cancer were 94.4%, 87.5% and 92.3% respectively and those of 99Tcm-MIBI were 88.9%, 75.0% and 84.6% respectively. Significant difference was found between 99Tcm-Octreotide and 99Tcm-MIBI in both of specificity and accuracy (P<0.05 and P<0.01). The sensitivity, specificity and accuracy of 99Tcm-Octreotide scintigraphy in the detection of axillary lymph node involvement were 66.7%, 92.9% and 80.8% respectively. Those of 99Tcm-MIBI were 58.3%, 85.7% and 73.1% respectively. The specificity showed significant difference between 99Tcm-Octreotide and 99Tcm-MIBI (P<0.01). Conclusion 99Tcm-Octreotide somatostatin receptor imaging may be superior to 99Tcm-MIBI in the detection of primary breast cancer and axillary lymph node involvement, and 99Tcm-Octreotide scintigraphy before operation is helpful in working out operative modality for patients.

    Release date:2016-08-28 04:43 Export PDF Favorites Scan
  • 99mTc-亚锡焦磷酸钠乳腺显像对乳腺疾病的诊断价值

    Release date:2016-08-29 03:18 Export PDF Favorites Scan
  • Combined with diffusion tensor imaging and proton densityweighted magnetic resonance imaging on the visual pathway of central nervous system in patients with glaucoma

    Objective To observe the changes of visual pathway of central nervous system in patients with glaucoma.Methods Thirty-five subjects were enrolled in this prospective study. There were seven patients of chronic primary angle closure glaucoma with bilateral visual field defects, 12 patients of primary open angle glaucoma with bilateral visual field defects, and 16 normal subjects. GE Signa HD 1.5 T magnetic resonance scanners and head eight phased array were used. The mean fractional anisotropy (FA) and the mean average diffusion coefficient (DCavg) of white matter tracts in visual pathway of bilateral optic nerve, optic chiasma, bilateral optic tract,bilateral optic radiation were measured by diffusion tensor imaging, meanwhile the white matter tracts were reconstructed by fiber tracking system. The volumes of lateral geniculate body were measured by coronal proton density weighted magnetic resonance imaging.Results The differences of FA among bilateral optic nerve, optic chiasma, bilateral optic tract,bilateral optic radiation were statistically significant (F=25.985,20.626,12.262,22.399,21.708,24.994,22.774;P<0.05). There was no difference of DCavg among bilateral optic nerve, optic chiasma, bilateral optic tract,bilateral optic radiation(F=2.097,2.178,0.530,0.983,0.608, 0.866, 1.504;P>0.05). The differences of volume of lateral geniculate body among three groups were statistically significant (F=18.631,17.274;P<0.05). Conclusion There is degeneration in visual pathway of central nervous system in patients with glaucoma.

    Release date:2016-09-02 05:26 Export PDF Favorites Scan
  • Comparative Ultrasonography with Radionuclide Imaging Evaluating Parotid of Sjogren Syndrome

    摘要:目的:探讨超声与核素显像在评价干燥综合征(SS)腮腺受累情况中的价值和作用。方法:对65例SS病人分别进行超声和核素显像检查。结果:超声判为腮腺功能0级、I级、ⅡⅢ级、Ⅳ级的能力与核素显像判为正常(χ2=0.075,Pgt;0.05)、轻度(χ2=0.12,Pgt;0.05)、中度(χ2=0.27,Pgt;0.05)、重度(χ2=0.097,Pgt;0.05)受损的能力一致,差异无统计学意义;核素发现单纯摄取功能受损的超声多表现为不均匀型、单纯排泌功能受损的超声多表现为结节型、摄取和排泌功能均受损的超声多表现为纤维化型。结论:超声检查可作为SS患者腮腺受累情况评价的良好手段。Abstract: Objective: To quantitatively evaluate ultrasonography and radionuclide imaging in thediagnosis of parotid gland involvement in Sjogren syndrome (SS). Methods: Ultrasonography and radionuclide imaging were conducted on 65 cases with primary Sjogren syndrome. Results: There was no significant difference statistically between the ultrasonographic appearance of the parotid gland and radionuclide imaging (P gt;0. 05). Conclusion: As for diagnosis and evaluating the parotid gland of Sjogren syndrome, ultrasonography may be the useful choice.

    Release date:2016-09-08 10:12 Export PDF Favorites Scan
  • Clinical Evaluation of Regional Electric Impedance Pneumograph and Scintigraphy in Patiens with COPD

    摘要:目的:应用区域阻抗法测定慢性阻塞性肺疾病(COPD)患者的肺血流灌注及肺通气分布的变化,与放射性核素肺显像方法比较,探讨肺区域阻抗方法的临床应用价值。 方法: 测定对象为18例中重度COPD患者,均为男性,平均年龄63.8岁,应用肺区域阻抗法及放射性核素法,分别测定肺血流灌注及肺通气的分布。〖HTH〗结果〖HTSS〗: 本研究发现肺区域阻抗法在测定肺血流灌注分布方面,仅在左下肺区域高于核素法测得的数值(Plt;0.05),余肺区测定结果相近,无显著差异。在肺通气的测定方面,阻抗法所得数值与核素法测得的数值有一定的不同,在左上、右上区域高于核素法测得的数值,在左中肺区测得的数值低于核素法测得的数值(Plt;0.05),余肺区测定结果相近,无显著差异。结论: 虽然目前区域阻抗方法暂不能取代放射性核素的测定,但作为一种辅助手段,可简便、快速了解肺内的通气、血流等生理病理改变。Abstract: Objective: To evaluate the clinical capability of regional electric impedance pneumograph and scintigraphy in measurement of pulmonary perfusion and ventilation in patients with COPD. Methods: Thirtytwo patients with different respiratory diseases underwent regional electric impedance pneumograph and scintigraphy, the pulmonary perfusion and ventilation were obtained and recorded. Results:The pulmonary perfusion results got by regional electric impedance pneumograph in the left lower region was lower than the results measured by scintigraphy, there were significant difference (Plt;0.05), and no difference in other pulmonary region. The pulmonary ventilation results got by regional electric impedance pneumograph in the both upper region were higher and in the left middle region were lower than the results measured by scintigraphy, there were significant difference(Plt;0.05), and no difference in other pulmonary region. Conclusion:The result got by regional electric impedance pneumograph could not replace the result got by scintigraphy at present, but this is a quick, simple,and convenient measurement to get parameter of the pulmonary perfusion and ventilation.

    Release date:2016-09-08 10:12 Export PDF Favorites Scan