Objective To evaluate the value of magnetic resonanace imaging (MRI) on the diagnosis of complex anal fistula. Methods The preoperative digital examination and MRI with the phased-array coil were implemented for 22 patients who were clinically suspected with complex anal fistula. The final diagnosis were based on surgical findings. Outcomes of MRI and digital examination were compared with surgical results. Results Eighteen patients were diagnosed as complex anal fistula, 1 case of presacral cyst and 3 cases of chronic anorectal fistula combined with perianal mucinous adenocarcinoma. All the patients were correctly diagnosed by MRI, while the patients with presacral cyst and perinaal mucinous adenocarcinoma could not be diagnosed correctly by digital examination. According to the Parks classification, 3 patients suffered from transsphincteric fistula, 11 cases of supra-sphincteric and 5 cases of extra-sphincteric fistula. The diagnosis rates of the internal opening with digital examination and MRI were 33.3% and 72.2%, the rates of the primary tract were 83.3% and 100%, and the rates of the secondary extensions were 16.7% and 88.9%, respectively. The differences in detection of internal opening and secondary extensions between MRI and digital examination were significant (P=0.019, P=0.000), the difference in detection of primary tract was no significant (P=0.072). Conclusion MRI with the phased-array coil can develope the high accuracy in the diagnosis of complex anal fistulas, and reveal the relationship between anorectal sphincters and the complex fistula.
ObjectiveTo study the effects of the new small molecular oxygen free radical scavenger Tempol on the survival and vasculogenesis of the long random pattern skin flap (LRPSF) and its mechanism. MethodsEighty-four male Sprague Dawley rats were randomly divided into control and Tempol groups (42 rats in each group). LRPSF of 9 cm×3 cm in size were prepared on the backs of rats in two groups based on the Mcfarlane flap. Rats were administered with Tempol (100 mg/kg) in the Tempol group and with normal saline in the control group by intraperitoneal injection at 15 minutes before operation and at 1-7 day after operation. The rat and the skin flap survival conditions were observed after operation; the survival rate of skin flap was measured, and the vascular structure, vascular volume, and total length of blood vessels were analyzed with Micro-CT three-dimensional imaging after 7 days; HE staining was used to observe the structure of the skin flaps and inflammation, immumohistochemical staining to observe vascular endothelial growth factor (VEGF) expression; water-soluble tetrazolium-1 method was used to measure the content of superoxide dismutase (SOD) and malondialdehyde (MDA), and ELISA to detect the expressions of tumor necrosis factor α (TNF-α) and interleukin 6 (IL-6) after 1, 3, and 7 days. ResultsAll of rats survived after operation, without hemorrhage, edema, and infection. With the extension of time, necrosis occurred in the distal part of the skin flaps in 2 groups, but the necrosis degree of the Tempol group was lower than that of control group; meanwhile, the blood vessel distribution and continuity were better than those of control group. The skin flaps survival rate, vascular volume, and total length of blood vessels of Tempol group were significantly higher than those of control group after 7 days (P<0.05). The clearer skin flaps structure, lighter inflammation reaction and inflammation cell infiltration, and higher VEGF staining intensity were observed in the Tempol group than the control group after 7 days. There was no significant difference in SOD, MDA, and TNF-α, and IL-6 contents between the 2 groups at immediate after operation. SOD significantly increased, but MDA, TNF-α, and IL-6 contents significantly decreased in the Tempol group when compared with control group after 1, 3, and 7 days (P<0.05). ConclusionTempol can significantly promote the LRPSF survival rates, its mechanism is closely related to the promotion of vasculogenesis and reduction of oxidative stress and inflammation.
Objective To investigate the effectiveness of the digital technology in repairing tiny hand wounds with superficial lateral sural artery perforator flap. Methods Between August 2013 and October 2016, 10 cases of tiny hand wounds were treated with the superficial lateral sural artery perforator flap. There were 6 males and 4 females, aged 19 to 47 years (mean, 31.2 years). The causes included crushing injury by machine in 6 cases, traffic accident injury in 3 cases, and electric burning injury in 1 case. The location of the soft tissue defect was the first web in 2 cases, the thumb pulp in 3 cases, the index finger pulp in 1 case, the dorsal palms in 3 cases, and the dorsum of finger in 1 case. The time from injury to hospitalization was 4 hours to 10 days (mean, 3.5 days). The size of wound was from 4 cm×3 cm to 8 cm×7 cm. All defects were associated with exposure of tendon and bone. CT angiography (CTA) from aortaventralis to bilateral anterior and posterior tibial arteries was performed before operation, and the appropriate donor site as well as perforator was selected. Then the CTA data were imported into the Mimics15.0 software to reconstruct the three dimensional structure of the perforator artery, bone, and skin; according to flap size, the flap design and harvesting process were simulated. The flap was obtained on the basis of preoperative design during operation. The size of flaps varied from 5 cm×4 cm to 10 cm×8 cm. The donor site was sutured directly in 9 cases and repaired with skin grafting in 1 case. Results Superficial medial sural artery peforator was cut in 3 patients whose superficial lateral sural artery was too narrow, and the flaps were obtained to repair defects smoothly in the others. Venous crisis occurred in 1 flap, which survived after exploration of the vessel, thrombus extraction, and thrombolysis; the other flaps survived successfully. All wounds and incisions healed by first intention. All cases were followed up 3-18 months (mean, 10 months). The flaps had good shape. At last follow-up, the results were excellent in 6 cases, good in 3 cases, and fair in 1 case according to total active motion (TAM). Conclusion The preoperative individualized design of the superficial lateral artery perforator flap can realize through CTA digital technology and Mimics15.0 software; it can reduce the operation risk and is one of better ways to repair the tiny hand wounds.