west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "杨小海" 2 results
  • 分期手术微创锁定加压钢板治疗高能量Pilon骨折

    目的 总结分期手术微创锁定加压钢板内固定治疗高能量Pilon 骨折的临床疗效。 方法 2006 年4 月- 2010 年3 月,采用一期行有限复位外支架固定,二期通过微创经皮钢板固定技术(minimally invasive percutaneous plate osteosynthesis,MIPPO)行锁定加压钢板内固定治疗Pilon 骨折21 例。其中男16 例,女5 例;年龄25 ~ 68 岁,平均42.2 岁。根据AO 分型:C2 型15 例,C3 型6 例。闭合骨折8 例;开放骨折13 例,根据Gustilo 分型:Ⅱ型8 例,Ⅲ型5 例。18 例合并同侧腓骨骨折。 结果 术后发生皮肤坏死3 例,创面感染2 例,均经对症治疗后愈合;其余患者切口均Ⅰ期愈合。21 例均获随访,随访时间12 ~ 16 个月,平均13.2 个月。X 线片示骨折均愈合,愈合时间为12 ~ 18 周,平均14 周。无短缩和旋转畸形,无钉道感染、内固定物松动等并发症发生。术后10 个月踝关节功能按Mazur 系统评估,获优11 例,良6 例,可3 例,差1 例,优良率81%。 结论 一期行有限复位外支架固定,二期采用MIPPO 技术行锁定加压钢板内固定是治疗高能量Pilon 骨折的较满意方法。

    Release date:2016-08-31 05:42 Export PDF Favorites Scan
  • Clinical observation of 3.5 mm T support plate fixation for simple posterolateral tibial plateau fracture by posterolateral inverted L-shaped approach

    Objective To summarize the effectiveness of 3.5 mm T support plate fixation for simple postero-lateral tibial plateau fractures by posterolateral inverted L-shaped approach. Methods Between March 2011 and January 2016, 13 patients with simple posterolateral tibial plateau fracture were treated with 3.5 mm T support plate fixation by posterolateral inverted L-shaped approach. Of 13 cases, 6 were male and 7 were female, aged 28 to 52 years (mean, 43 years). The left side was involved in 5 cases and the right side in 8 cases. The causes of injury were traffic accidents in 6 cases, falls in 3 cases, and falling from height in 4 cases. All of patients had fresh closed fracture by X-ray, CT three dimensional reconstruction, and MRI. According to Schatzker classification, 4 cases were rated as type II and 9 cases as type III. The time between injury and operation was 5-9 days (mean, 7 days). Results One case had incision skin necrosis, which was cured after debridement and skin grafting; and primary healing was obtained in the other cases. The patients were followed up 10-16 months (mean, 13 months). The X-ray film showed that the fracture line was blurred at 3 months after operation, and disappeared at 12 months after operation. There was no complications of wound infection, major neurovascular injury, loosening or breakage of internal fixation, and dislocation of joint surface. The Hospital for Special Surgery (HSS) knee function score was 94 (range, 89-97) at last follow-up; all were excellent. Conclusion The 3.5 mm T support plate fixation by posterolateral inverted L-shaped approach is one of preferred surgical method for the treatment of simple posterolateral tibial plateau fractures.

    Release date:2017-07-13 11:11 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content