west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "樊瑜波" 20 results
  • 可穿戴医疗/健康技术——生物医学工程的机遇和挑战

    Release date: Export PDF Favorites Scan
  • Recent research progress of bioactivity mechanism and application of bone repair materials

    Large bone defect repair is a difficult problem to be solved urgently in orthopaedic field, and the application of bone repair materials is a feasible method to solve this problem. Therefore, bone repair materials have been continuously developed, and have evolved from autogenous bone grafts, allograft bone grafts, and inert materials to highly active and multifunctional bone tissue engineering scaffold materials. In this paper, the related mechanism of bone repair materials, the application of bone repair materials, and the exploration of new bone repair materials are introduced to present the research status and advance of the bone repair materials, and the development direction is also prospected.

    Release date:2018-09-03 10:13 Export PDF Favorites Scan
  • Simulation of spontaneous breathing for healthy adults using a nonlinear airway-segmented model of respiratory mechanics

    One-compartment lumped-parameter models of respiratory mechanics, representing the airflow resistance of the tracheobronchial tree with a linear or nonlinear resistor, are not able to describe the mechanical property of airways in different generations. Therefore, based on the anatomic structure of tracheobronchial tree and the mechanical property of airways in each generation, this study classified the human airways into three segments: the upper airway segment, the collapsible airway segment, and the small airway segment. Finally, a nonlinear, multi-compartment lumped-parameter model of respiratory mechanics with three airway segments was established. With the respiratory muscle effort as driving pressure, the model was used to simulate the tidal breathing of healthy adults. The results were consistent with the physiological data and the previously published results, suggesting that this model could be used for pathophysiological research of respiratory system.

    Release date:2019-02-18 03:16 Export PDF Favorites Scan
  • Bibliometric analysis on international cooperation of rehabilitation robots in China from 2000 to 2019

    Rapid development is undergoing in the field of rehabilitation robots, and more countries (regions) are participating in international cooperation and becoming academic contributors. Here in this study, the bibliometric method is used to determine the dynamics and developments of international cooperation in China. The publication data are indexed in Web of Science with search term of rehabilitation robot from 2000 to 2019. Compared with other countries (regions), publication with international co-authors and institutes participating in international cooperation are studied by assessment of indicators such as the cooperation degree, cooperation frequency, and the frequency of citations. The results show that in the past two decades, international scientific cooperation has shown a positive tendency in China, and participating in international collaboration could improve China’s impact on the global rehabilitation robot. The United States, England and Japan are the top three countries in number of cooperation with China. Our findings provide valuable information for researchers to better understand China’s international scientific collaboration in rehabilitation robot.

    Release date:2020-10-20 05:56 Export PDF Favorites Scan
  • Differentiation of stem cells regulated by biophysical cues

    Stem cells have been regarded with promising application potential in tissue engineering and regenerative medicine due to their self-renewal and multidirectional differentiation abilities. However, their fate is relied on their local microenvironment, or niche. Recent studied have demonstrated that biophysical factors, defined as physical microenvironment in which stem cells located play a vital role in regulating stem cell committed differentiation. In vitro, synthetic physical microenvironments can be used to precisely control a variety of biophysical properties. On this basis, the effect of biophysical properties such as matrix stiffness, matrix topography and mechanical force on the committed differentiation of stem cells was further investigated. This paper summarizes the approach of mechanical models of artificial physical microenvironment and reviews the effects of different biophysical characteristics on stem cell differentiation, in order to provide reference for future research and development in related fields.

    Release date: Export PDF Favorites Scan
  • Biomechanical Study on Restorative Methods of Unilateral Maxilla Based on Finite Element Analysis

    This paper is to report our study in which the differences between prosthetic restoration and surgical reconstruction using traditional clasp retention technology were analyzed based on three-dimensional finite element methods in our laboratory. Firstly, the maxillary unilateral defect model was developed using medical image processing software MIMICS. Secondly, the prosthesis was generated by mirroring technology. The clasp was designed according to the methods raised by Aramany. Then, the stress distribution of maxilla was calculated by simulating occlusion. According to the results, after osseointegration of surgical reconstruction, stresses of unaffected abutments were reduced significantly, and less stress of junction occurred near zygoma of affected side, which were all less than stresses of prosthesis restoration. Thus, removing the clasp of surgical reconstruction increased the stresses of unaffected abutments. The stress trends of maxillary components were different between prosthetic restoration and surgical reconstruction. Surgical reconstruction is better than prosthesis restoration in protection of the abutments. Clasp can alleviate the occlusal burden of maxilla. Varieties of retentive technologies can be considered in prosthesis restoration. The surgical reconstruction is more conducive to rehabilitate unilateral maxilla biomechanically in clinic.

    Release date: Export PDF Favorites Scan
  • Experimental Study on Influence of Driving Speed on Foam Stability in Sclerotherapy for the Treatment of Varicose Veins

    Foam sclerotherapy is one of the major therapies for varicose veins in lower limbs. It is important to know the influence factor of foam stability which is beneficial to curative effect. The present experiment explored influence of 9 kinds of driving speed on foam stability when using the method of Tessari. Syringes of 5 mL were chosen to do this experiment which was carried out at the liquid gas ratio of 1:4 and the environment temperature of 20℃. A home-made automatic sclerosing foam preparation equipment was used to prepare the foam. A camera recorded the entire process of foam decay. And foam stability indexes which includes drainage time, half-life, foam half-life volume and the drainage rate curve, were analyzed. The results showed that when driving speed ranged from 100 mm/s to 275 mm/s, foam drainage time and the half-life showed a trend of rising. When the driving velocity was greater than 275 mm/s, the foam drainage time and half-life time reduced a little. The largest drainage time and the half-life differences were 340.0% and 118.8% compared to their minimum value. Meanwhile the pressure increased with the increase of driving speed, so that the solubility of carbon dioxide increased and the foam half-life volume decreased with the increase of the driving speed. It can be concluded that when using the method of Tessari to prepare sclerosing foam, driving speed has a significant effect on its stability. With driving speed increasing, foam decay mechanism changes from gas diffusion to liquid drainage as the main function, so the foam stability increased at first and then decreased later. The foam is relatively more stable at the speed of 275 mm/s, which could be considered as the best driving speed.

    Release date:2016-10-24 01:24 Export PDF Favorites Scan
  • Estimation of lung recruitment characteristics using the static pressure-volume curve of lungs

    Mechanical ventilation is an importmant life-sustaining treatment for patients with acute respiratory distress syndrome. Its clinical outcomes depend on patients’ characteristics of lung recruitment. Estimation of lung recruitment characteristics is valuable for the determination of ventilatory maneurvers and ventilator parameters. There is no easily-used, bedside method to assess lung recruitment characteristics. The present paper proposed a method to estimate lung recruitment characteristics from the static pressure-volume curve of lungs. The method was evaluated by comparing with published experimental data. Results of lung recruitment derived from the presented method were in high agreement with the published data, suggesting that the proposed method is capable to estimate lung recruitment characteristics. Since some advanced ventilators are capable to measure the static pressure-volume curve automatedly, the presented method is potential to be used at bedside, and it is helpful for clinicians to individualize ventilatory manuevers and the correpsonding ventilator parameters.

    Release date:2021-06-18 04:50 Export PDF Favorites Scan
  • Comparison of stent displacement and displacement force after endovascular aneurysm repair with cross-limb or parallel-limb stent

    This study aims to investigate whether displacement force on stents can accurately represents the displacement of the stent after endovascular aneurysm repair (EVAR) by comparing the measured stent displacement with the displacement forces calculated by computational fluid dynamics (CFD). And the effect of cross-limb and parallel-limb EVAR on stent displacements is further studied. Based on our objective, in this study, ten cross-limb EVAR patients and ten parallel-limb EVAR patients in West China Hospital of Sichuan University were enrolled. Patient-specific models were first reconstructed based on the computed tomography angiography images, then the stent displacements were measured, and the displacement forces acting on the stents were calculated by CFD. Finally, the \begin{document}$ \mathrm{cos}\;\alpha $\end{document} value of the angle between the displacement force and the displacement vector was used to analyze the matching degree between the displacement and the displacement force. The results showed that the displacement forces on cross-limb stents and parallel-limb stents were (2.67 ± 2.14) N and (1.36 ± 0.48) N, respectively. Displacements of stent gravity center, stent displacements relative to vessel, and vessel displacements of cross-limb and parallel-limb stents were (4.43 ± 2.81) mm and (6.39 ± 2.62) mm, (0.88 ± 0.67) mm and (1.11 ± 0.71) mm, (3.55 ± 2.88) mm and (5.28 ± 2.52) mm, respectively. The mean \begin{document}$ \mathrm{cos}\;\alpha $\end{document} for cross-limb and parallel-limb stents were 0.02 ± 0.66 and − 0.10 ± 0.73, respectively. This study indicates that the displacement force on the stent can’t accurately represent the displacement of the stent after EVAR. In addition, the cross-limb EVAR is probably safer and more stable than the parallel-limb EVAR.

    Release date: Export PDF Favorites Scan
  • Primary study on recognition of vascular stiffness based on wavelet scattering neural network

    Cardiovascular disease is the leading cause of death worldwide, accounting for 48.0% of all deaths in Europe and 34.3% in the United States. Studies have shown that arterial stiffness takes precedence over vascular structural changes and is therefore considered to be an independent predictor of many cardiovascular diseases. At the same time, the characteristics of Korotkoff signal is related to vascular compliance. The purpose of this study is to explore the feasibility of detecting vascular stiffness based on the characteristics of Korotkoff signal. First, the Korotkoff signals of normal and stiff vessels were collected and preprocessed. Then the scattering features of Korotkoff signal were extracted by wavelet scattering network. Next, the long short-term memory (LSTM) network was established as a classification model to classify the normal and stiff vessels according to the scattering features. Finally, the performance of the classification model was evaluated by some parameters, such as accuracy, sensitivity, and specificity. In this study, 97 cases of Korotkoff signal were collected, including 47 cases from normal vessels and 50 cases from stiff vessels, which were divided into training set and test set according to the ratio of 8 : 2. The accuracy, sensitivity and specificity of the final classification model was 86.4%, 92.3% and 77.8%, respectively. At present, non-invasive screening method for vascular stiffness is very limited. The results of this study show that the characteristics of Korotkoff signal are affected by vascular compliance, and it is feasible to use the characteristics of Korotkoff signal to detect vascular stiffness. This study might be providing a new idea for non-invasive detection of vascular stiffness.

    Release date: Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content