Objective To investigate the current situation and developing trend of antithrombotic function study of endothelium in vasculartissue engineering. Methods The effect of several elements onthe antithrombotic ability of endothelium, including the source of endothelium,the characteristic of the matrix materials, the cell culture methods, and the endothelium’s gene modification were analyzed. Results The normal antithrombotic function of tissue engineered vascular relied on the source ofendothelium, gene modification of seeding cells, the cell culture methods in vitro, and the characteristic of the scaffolds. Conclusion The establishment of an ideal antithrombotic functional tissue engineering vascular still requires further studies in various aspects including seeding cells, matrix materials, and cell culture methods. Gene modification of vascular endothelium, which improves the antithrombotic ability, deserves more attention.
OBJECTIVE To study the biocompatibility on bioactive glass ceramics (BGC) and polylactic acid (PLA) combined with cultured bone marrow stromal cells (BMSCs) in bone tissue engineering. METHODS BMSCs were cultured combined with BGC and PLA in vitro, and the morphological characters, cell proliferation, protein content, and alkaline phosphatase activity were detected. RESULTS: BMSCs could be attached to and extended on both BGC and PLA, and normally grown, proliferated, had active function. BGC could promote cell proliferation. CONCLUSION The results show that both BGC and PLA have good biocompatibility with BMSCs, they can be used as biomaterials for cell transplantation in tissue engineering.
OBJECTIVE: To investigate the selection and manufacture of ideal extracellular matrix materials in bone tissue engineering. METHODS: The recent literatures about biodegradable polymers served as culture scaffolds of osteoblasts were widely reviewed, the advantages and disadvantages of biodegradable synthetic polymers and natural polymers were analysed. RESULTS: The ideal extracellular matrix material in bone tissue engineering should be made up of inorganic materials, synthetic polymers and natural polymers, which possesses morphological structure of three-dimensional foam with self-mediated drug slow delivery system of bone growth factors. CONCLUSION: The design and manufacture of combined extracellular matrix materials in bone tissue engineering is a very important and urgent challenge.
OBJECTIVE: To evaluate the function of injured hand after repair of finger stump and reconstruction of digit tendon attachment in finger amputation. METHODS: From 1992 to 1998, 20 cases with amputation of the 2nd to the 5th fingers were investigated, of which reconstruction of digit tendon attachment in 10 cases (group A) and routine operation without reconstruction of digit tendon attachment in other 10 cases (group B). After 6 months of operation, the tension test, fatigue test the sense of stability in motion and the perimeter of forearm in injured hand and the corresponding healthy hand were compared. RESULTS: The differences were remarkable (P lt; 0.01) between group A and group B in the tension test of injured finger, the fatigue test, the sense of stability in motion and the perimeter of injured arm. CONCLUSION: The digit of injured finger should be reconstructed in finger amputation in order to furthest maintain the function of injured hand.
Objective To evaluate the diagnostic value of human heart-type fatty acid-binding protein for early detection of acute myocardial infarction (AMI). Methods Studies involving this biomarker were identified from MEDLINE, EMbase, CBM and VIP (1970 to 2006). Relevant journals (1980 to 2006) were also handsearched. The quality of the included studies was assessed using the QUADAS tool. Data extraction and analysis were conducted by software of EXCEL2003 and Metadisc. Results We included 13 studies, which were heterogeneous (P=0, I2=58.5%). Five studies (n=396) included in the group assessed the test at the first three hours after chest pain onset. These studies were homogeneous (P= 0.49, I2=0). The pooled sensitivity was 0.86 ( 95%CI 0.80 to 0.91), the pooled specificity was 0.76( 95%CI 0.80 to 0.91), and the area under the curve was 0.88 (SE=0.032 3). In the group of 0 to 6 hours after chest pain onset, 10 included studies (n=1 175) were heterogeneous (P=0, I2=69%). The pooled sensitivity was 0.86 (95%CI 0.83 to 0.89), the pooled specificity was 0.79 (95%CI 0.76 to 0.82), and the area under the curve was 0.92 (SE=0.019). In the group of 6 to 12 hours after chest pain onset, 4 included studies (n=215) were homogeneous (P=0.56, I2=0). The pooled sensitivity was 0.97 (95%CI 0.91 to 0.99), the pooled specificity was 0.52 (95%CI 0.42 to 0.61), and the area under the curve was 0.810 with (SE=0.152 2). In the group of 0 to 12 hours after chest pain, 11 included studies (n=1 352) were heterogeneous (P=0.56, I2=59%). The pooled sensitivity was 0.88 (95%CI 0.84 to 0.89), the pooled specificity was 0.75 (95%CI 0.71 to 0.78), and the areas under the curve was 0.91 (SE=0.016 4). Conclusions In this systematic review, we found that H-FABP has an acceptable diagnostic accuracy within 3 hours after the onset of symptoms, and within 12 hours after the onset of symptoms, H-FABP has a high diagnostic efficacy. So H-FABP may be a new symbol for the early diagnosis of AMI.