west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "王开明" 3 results
  • 内侧腓肠肌岛状肌皮瓣修复膝部创面

    Release date:2016-09-01 11:07 Export PDF Favorites Scan
  • Application of improved injecting tube in percutaneous kyphoplasty through unipedicular puncturing

    Objective To research the feasibility and effectiveness of percutaneous kyphoplasty (PKP) by improved injecting tube through unipedicular puncturing. Methods Between January 2012 and Junuary 2016, 60 cases (68 vertebrae) of osteoporotic vertebral compression fractures (OVCF) were treated. PKP was performed through unipedicular puncturing with routine injecting tube in 30 cases (34 vertebrae, routine group), and with improved injecting tube in 30 cases (34 vertebrae, improved group). There was no significant difference in age, gender, disease duration, fracture level, preoperative visual analogue scale (VAS), or vertebral height between 2 groups (P>0.05). The operation time, the volume of bone cement injected, preoperative and postoperative VAS, and preoperative and postoperative vertebral height, and postoperative distribution coefficient of bone cement were recorded and compared between 2 groups. Results Good healing of puncture points was achieved in 2 groups after PKP, and no serious complication occurred. There was no significant difference in operation time and the volum of bone cement injected between 2 groups (t=0.851,P=0.399;t=1.672,P=0.101). Bone cement leakage was observed in 2 cases of 2 groups respectively. The distribution coefficient of bone cement in routine group was significantly less than that in improved group (t=13.049,P=0.000). All patients were followed up 12-36 months (mean, 19 months). The postoperative VAS and vertebral height were significantly improved when compared with preoperative ones in 2 groups (P<0.05), but there was no significant difference in VAS between at 2 days after operation and at last follow-up, in vertebral height between at 2 days after operation and at 1 year after operation, and between 2 groups after operation (P>0.05). X-ray films showed vertebral compression fractures in 6 cases of routine group and in 1 case of improved group during follow-up. Conclusion PKP by improved injecting tube through unipedicular puncturing can improve the distribution of bone cement, restore the height and strength of vertebral body, and reduce the incidence of re-fracture.

    Release date:2017-03-13 01:37 Export PDF Favorites Scan
  • Calcaneal plate bridge reconstruction plate for acetabular fracture involving quadrilateral surface via modified Stoppa approach

    ObjectiveTo explore the effectiveness of the calcaneal plate bridge reconstruction plate for acetabular fracture involving quadrilateral surface via modified Stoppa approach.MethodsBetween January 2015 and December 2017, 18 patients with acetabular fracture involving quadrilateral surface were treated with the calcaneal plate bridge reconstruction plate via the modified Stoppa approach. There were 12 males and 6 females. The age ranged from 28 to 63 years (mean, 39 years). The cause of injury was traffic accident in 13 cases and falling from height in 5 cases. According to the Letournel-Judet classification, there were 10 cases of anterior and posterior column fractures, 6 cases of T-shaped fractures, and 2 cases of anterior column and posterior semi-transevere fractures. The interval from injury to operation was 6 to 24 days (mean, 8.6 days). The reduction quality was assessed by postoperative X-ray film and CT according to the criteria proposed by Matta. The hip joint function was assessed by the modified Merled’Aubigné-Postel score.ResultsThe operation time was 120-240 minutes (mean, 165 minutes) and the intraoperative blood loss was 600-1 400 mL (mean, 850 mL). All patients were followed up 18-30 months (mean, 24.5 months). There were 2 cases of the fat liquefaction of abdominal incisions, 3 cases of intraoperative injury of lateral femoral cutaneous nerve, 1 case of lower limb thrombosis, and 1 case of abdominal pain and hematuria due to intraoperative accidental bladder injury. According to the criteria proposed by Matta, the reduction quality rated as anatomic reduction in 12 cases, satisfactory reduction in 5 cases, and unsatisfied reduction in 1 case, and the satisfaction rate was 94.4%. All fractures healed with the healing time of 3-5 months (mean, 3.4 months). During follow-up, no internal fixator loosening, breakage, or fracture displacement occurred. At last follow-up, according to modified Merled’Aubigné-Postel score, hip joint functions rated as excellent in 11 cases, good in 4 cases, fair in 2 cases, and poor in 1 case. The excellent and good rate was 83.3%.ConclusionApplication of calcaneal plate bridge reconstruction plate via the modified Stoppa approach for the acetabular fracture involving the quadrilateral surface can obtain satisfactory effectiveness.

    Release date:2020-11-02 06:24 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content