  • 成人小主动脉瓣环患者的心瓣膜置换术

    目的 总结成人小主动脉瓣环行心瓣膜置换术的临床经验,以提高手术效果。 方法 对26例成人小主动脉瓣环患者行人工机械瓣膜置换术,单纯主动脉瓣置换17例,二尖瓣、主动脉瓣双瓣膜置换9例。采用Manougnian法主动脉瓣环加宽7例,瓣膜侧倾缝合置换主动脉瓣膜6例,瓣环上主动脉瓣置换13例,在双瓣膜置换中均先置换主动脉瓣后再置换二尖瓣。 结果 26例患者中无手术死亡,术后随访时间6~48个月(12±3个月),心功能均明显改善(Ⅰ级10例、Ⅱ级16例),无远期死亡。术后主动脉瓣有效瓣口面积指数(EOAI)1.02~1.44 cm2/m2(>0.85 cm2/m2), 无瓣膜患者不匹配现象(PPM)。 结论 主动脉瓣病变伴小主动脉瓣环的成人患者行心瓣膜置换,选择新型人工瓣膜行瓣环上主动脉瓣置换是理想的选择,瓣膜侧倾缝合是可选择的方法,二尖瓣、主动脉瓣双瓣膜置换时先置换主动脉瓣可降低手术操作难度,大部分患者无需行瓣环扩大术。

    Release date:2016-08-30 06:08 Export PDF Favorites Scan
  • The Effective Orifice Area and Haemodynamics of 19mm St. Jude Regent Valve——An Early in Vivo Study

    Abstract: Objective To investigate the in vivo effective orifice area (EOA) and whether prosthesispatient mismatch (PPM) is going to happen after 19mm St.Jude Regent valves replacement were performed. Methods Twentythree patients with valvular heart diseases were divided into 2 groups according to aortic annular diameter. 19mm St. Jude Regent valves were replaced in aortic valve place (Regent valve group), and 21mm other doubleleaflet mechanical valves were replaced in aortic place (other valves group). All of the operations were accomplished under cardiopulmonary bypass in West China Hospital. All of the patients were followed up in 3 to 6 months after their surgery processes. Color Doppler echocardiography was used to measure the hemodynamic parameters in their followup. Then left ventricular mass (LV mass), EOA and effective orifice area index (EOAI) etc. were calculated and compared by using SPSS 12.0. Results No cardiac episodes were detected during the perioperative period and 36 months after operation. LVmass reduced in 36 months after operation in both groups. No statistical significance of EOA, EOAI and LVmass reduction were detected between the two groups. Conclusions (1)The EOA and in vivo hemodynamic effects of 19mm Regent valve are similar to 21mm other double leaflet mechanical valve. (2)It is safe to use 19mm Regent valve in those patients whose aortic annular diameter are small and need double valve replacement. Using 19mm Regent valve will not cause short time cardiac episodes and PPM. (3)More further works should be done to make sure what is the standard of PPM in Chinese people, such as enlarging the patients number and prolonging the followup time. (4) Further clinical and followup works should be done to make St.Jude Regent valve’s feature out.

    Release date:2016-08-30 06:16 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content