Abstract:Since 1978 the definition of prosthesis-patient mismatch(PPM) was first introduced by Rahimtoola, it has attracted the attention of foreign researchers. The PPM phenomenon is concerned to be an important factor which will affect patients' survival rate and quality of life. Till now, a lot of effort should still be put on this problem. But unfortunately, this problem is still being neglected in our country. This paper is a review of PPM from it's many aspects, such as definition, current research status, prevention, and it's research prospect. We hope this paper will intensify the clinicians' knowledge on PPM.
Objective To investigate the further results of thoracoabdominal aortic aneurysm (TAAA) repair, and analyze the midterm results of 63 cases treated by total thoraco abdominal aortic replacement with a tetrafurcate graft. Methods From August 2003 to October 2007,total thoracoabdominal aortic replacement with a tetrafurcate graft was performed in 63 consecutive patients with Crawford Ⅱ TAAA in Fu Wai Hospital. There were 46 male and 17 female with a mean age of 39.98 years (17-71 years). All the procedures were performed through combined thoracoabdominal incision via the retroperitoneal approach and underwent profound hypothermia with shorttime interval circulatory arrest. T6 to T12 intercostal arteries were reconstructed by arterial tube technique. The celiac artery, superior mesenteric artery and right renal artery were joined into a patch and anastomosed to the end of the main graft. Left renal artery was anastomosed to an 8 mm branch or joined to the visceral arterial patch. The other 10 mm branches were anastomosed to iliac arteries. KaplanMeier method was used to perform survival analysis. Results All the cases were followed,and the mean followup time was 36.57(8-57) months. No patient died during the operation. Early mortality rate was 7.94%(5/63). Among them, 4 patients died of multiple organ failure. Two of them were caused by neurological complications, and the other 2 of them were caused by renal failure. One patient died of low cardiac output syndrome after surgery because of coronary artery disease. This patient underwent coronary artery bypass grafting (CABG) emergently, but couldn’t wean from cardiopulmonary bypass. The incidence of stroke and temporary neurological dysfunction was 9.52%(6/63), 4 of them were temporary neurological dysfunction and were cured before discharged from hospital. Paraplegia and paraparesis occurred in 2 and 1, respectively. They were all [CM(158.3mm]cured before leaving hospital. Pulmonary complication was 25.40%(16/63), and12 of them were cured. Pseudoaneurysmal change was observed in reconstructed intercostal arteries in 2 patients with Marfan syndrome, but neither of them underwent paraplegia or paraparesis. One patient died at 20th, 23rd, 30th month after discharge, respectively. The survival time of this group was 50.64±2.13 months(95%CI:46.47,54.84 months) with a survival rate of 92.06% after 1 year, 88.38% after 2 years, 86.11% after 3 years. Conclusion Using tetrafurcate graft is a reliable method in total thoracoabdominal aortic replacement and has a satisfactory midterm survival rate. The intercostal arteries reconstruction by arterial tube technique in total thoracoabdominal replacement is simple, and it is helpful in spinal cord protection.
Abstract: Objective To investigate the in vivo effective orifice area (EOA) and whether prosthesispatient mismatch (PPM) is going to happen after 19mm St.Jude Regent valves replacement were performed. Methods Twentythree patients with valvular heart diseases were divided into 2 groups according to aortic annular diameter. 19mm St. Jude Regent valves were replaced in aortic valve place (Regent valve group), and 21mm other doubleleaflet mechanical valves were replaced in aortic place (other valves group). All of the operations were accomplished under cardiopulmonary bypass in West China Hospital. All of the patients were followed up in 3 to 6 months after their surgery processes. Color Doppler echocardiography was used to measure the hemodynamic parameters in their followup. Then left ventricular mass (LV mass), EOA and effective orifice area index (EOAI) etc. were calculated and compared by using SPSS 12.0. Results No cardiac episodes were detected during the perioperative period and 36 months after operation. LVmass reduced in 36 months after operation in both groups. No statistical significance of EOA, EOAI and LVmass reduction were detected between the two groups. Conclusions (1)The EOA and in vivo hemodynamic effects of 19mm Regent valve are similar to 21mm other double leaflet mechanical valve. (2)It is safe to use 19mm Regent valve in those patients whose aortic annular diameter are small and need double valve replacement. Using 19mm Regent valve will not cause short time cardiac episodes and PPM. (3)More further works should be done to make sure what is the standard of PPM in Chinese people, such as enlarging the patients number and prolonging the followup time. (4) Further clinical and followup works should be done to make St.Jude Regent valve’s feature out.
ObjectiveTo summarize clinical experience and surgical indications of open stented elephant trunk (sET) procedure for the treatment of complex acute Stanford type B aortic dissection (AD). MethodsFrom February 2009 to April 2013, 25 patients with complex acute Stanford type B AD underwent open sET procedure in Beijing Anzhen Hospital. There were 22 male and 3 female patients with their age of 46.92±9.12 years (range, 30 to 66 years). There were 16 patients with hypertension and 3 patients with preoperative acute renal failure. All the patients received sET implantation via an aortic arch incision under deep hypothermic circulatory arrest. Concomitant procedures included extra-anatomic bypass grafting in 11 patients, Bentall procedure in 1 patient, aortic valve replacement in 3 patients, and ascending aorta plasty in 3 patients. Computed tomography angiography (CTA) was performed before discharge and during follow-up for all the patients. ResultsOperation time was 4-7 (5.5±0.7) hours, cardiopulmonary bypass time was 93-206 (137.64±30.02) minutes, aortic cross-clamping time was 28-109 (57.96±21.05) minutes, and selective cerebral perfusion time was 15-76 (26.76±11.88) minutes. There was no in-hospital death. Postoperatively, there were 2 patients with pulmonary complications, 2 patients with type I endoleak, 1 patient with acute renal failure, 1 patient with temporary neurological disorder, 1 patient with sudden ventricular fibrillation, and 1 patient with delayed wound healing. Mean follow-up time was 6-54 (25.76±16.15) months, and 2 patients were lost during follow-up. The follow-up rate was 92%.There was no late death during follow-up. ConclusionsOpen sET procedure is a reliable and efficacious therapeutic strategy for patients with complex acute Stanford type B AD. Surgical indications include complex Stanford type B AD without enough landing zone, type B AD with ascending aortic disease, aortic root disease, valvular heart disease, coronary artery disease and congenital heart defects, and type B AD caused by genetic connective tissue disorder.
Objective To evaluate the short- and middle-term outcomes of surgical treatment for distal aortic arch lesions using stented elephant trunk implantation combined with transposition of left subclavian artery to left common carotid artery. Methods The clinical data of 14 patients with distal aortic arch lesions undergoing stented elephant trunk procedure with left subclavain artery transposition under hypothermic cardiopulmonary bypass (CPB) with antegrade selective cerebral perfusion from May 2009 to November 2015 in our hospital were retrospectively reviewed. All of them were males with a mean age of 52±14 years ranging from 20 to 69 years. Hypertension was observed in nine patients, coronary artery disease in five and prior cerebral infarction in one. History of percutaneous coronary intervention was noted in one patient, history of Bentall operation in one, ligation of patent ductus arteriosus in one and endovascular aneurysm repair in one. Results There was no hospital death. Concomitant procedures included coronary artery bypass grafting in two patients and plasty of the ascending aorta replacement in one. Mean duration of mechanical ventilation and ICU stay was 21±7 h and 43±19 h, respectively. All patients survived and were discharged. One patient was lost to follow-up and no patient died during the follow-up. Postoperative computed tomography revealed good patency of the anastomotic site between the left subclavian artery and the left common carotid artery. Conclusion Stented elephant trunk procedure with left subclavain artery transposition obtains satisfactory surgical results in patients with distal aortic arch lesions.