west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "经心尖" 19 results
  • Application of Three-dimensional CT Angiogram in Perioperative Evaluation for Patients Underwent Transapical Aortic Valve Implantation——The Initial Experience from West China hospital

    ObjectiveTo introduce the role of three dementional computed tomograph (3D-CT) for patients underwent transcatheter aortic valve implantation (TAVI) procedure in perioperative evaluation. MethodsFrom April 2014 to June 2015, we retrospectively analyzed clinical data of 28 patients with severe aortic stenosis underwent successful TAVI procedure using new second-generation device, who were enrolled in this study including 12 males and 16 females at mean age of 72.8±4.5 years. We used 3D-CT to get the perioperative relative evaluation, including valve morphology and calcification degree, annular diameter, aoronary ostium height, ascending aorta, aortic sinus diameter, left ventricular-aortic angle, optimal intraoperative angiogram projection angle. Based on the evaluation by 3D-CT image, the prosthesis size, balloon size, best intraoperative imaging projection angle and approach of apex were then chosen. ResultsAll patients with severe aortic stenosis underwent successful TAVI procedure with mean logistic Euro-SCORE I:26.2%±7.9%. CT image revealed that mean aortic annular diameter was 24.6±1.8 mm with mean valve prosthesis size 25.8±1.1 mm and pre-dilation balloon size 23.1±1.2 mm and 76.8% patients were of tricuspid aortic valve with severe calcification and 25% patients were of asymmetric calcification. Optimal intraoperative angiogram image was achieved in 92.9% patients with the help of preoperative CT image. There was a statistic difference in mean transvalvular gradient after valve implantation (54.1±15.3 mm Hg vs. 13.1±8.5 mm Hg, P<0.05). And there was no mortality or severe complication postoperatively. Conclusion3D-CT image palys an important role during perioperative evaluation of TAVI procedure and it can be helpful for Chinese doctors to operate TAVI successfully.

    Release date: Export PDF Favorites Scan
  • 心尖途径经导管主动脉瓣置换术治疗二叶式主动脉瓣狭窄一例

    Release date:2019-01-03 04:52 Export PDF Favorites Scan
  • 经导管二尖瓣置换术治疗功能性二尖瓣反流一例

    Release date:2018-11-27 04:47 Export PDF Favorites Scan
  • 应用 J-valve 瓣膜经心尖途径治疗超高龄单纯性主动脉瓣重度反流一例

    Release date:2019-05-28 09:28 Export PDF Favorites Scan
  • Percutaneous left ventricular transapical access guided by cardiac 3D CT angiography combined with echocardiography

    ObjectiveTo investigate the reliability and safety of the technique of percutaneous left ventricular transapical access guided by cardiac three dimensional CT angiography (3D-CTA) combined with echocardiography applied in structural heart defects.MethodsThe clinical data of 9 patients (7 males and 2 females with a median age of 50 years ranging from 43 to 64 years) with paravalvular leaks closed by percutaneous left ventricular transapical access in West China Hospital, from April 2015 to August 2018, were retrospectively analyzed. We applied preoperative cardiac 3D-CTA to define the puncture site and trace, which was established by combining with real-time guidance of transesophageal echocardiography (TEE/3D-TEE), and an occluder was deployed at the apical access point for hemostasis with real-time guidance of transthoracic echocardiography (TTE).ResultsThe puncture needles were successfully introduced into the left ventricular cavity at one time in all patients without injury of lung tissue, coronary artery or papillary muscle. There was no occluder displacement or apex bleeding. One patient developed pleural effusion caused by intercostal artery injury.ConclusionThat cardiac 3D-CTA is used to define puncture sites and trace with advantages of simplicity and repeatability. A safe access and secure exit of left ventricle can be achieved by combining with real-time guidance of echocardiography. There are acceptable technology-related complications.

    Release date:2019-06-18 10:20 Export PDF Favorites Scan
  • 应用 J-Valve 瓣膜行经心尖导管主动脉瓣置入术治疗主动脉瓣狭窄及主动脉瓣关闭不全各一例

    Release date:2019-09-18 03:45 Export PDF Favorites Scan
  • Safety of transcatheter aortic valve replacement through different approaches: A systematic review and meta-analysis

    ObjectiveTo evaluate the early and mid-term safety of transcatheter aortic valve replacement via transfemoral (TF), transapical (TAp) and transsubclavian (TSc) approaches by meta-analysis.MethodsWe systematically searched the clinical comparative trials published from inception to June 2019 from PubMed, Web of Science, EMbase and The Cochrane Library, to evaluate the safety of transcatheter aortic valve replacement through TF, TAp or TSc approaches. The information of all-cause mortality at 30 days, 1 year, 2 years and the incidence of common complications at 30 days after operation (including pacemaker-dependent block, major vascular complications, severe bleeding events, acute renal injury and stroke) were exacted, and a meta-analysis was conducted by RevMan 5.3 software.ResultsThis study included 11 literatures, with a total of 7 833 patients, among whom 5 348 patients were treated by TF TAVR, 1 796 patients by TAp TAVR and 689 patients by TSc TAVR. The results of the meta-analysis were as follows: (1) at 30 days after operation, the mortality of TF and TSc approaches were lower than that of the TAp approach (TF vs. TAp: OR=0.57, 95%CI 0.39-0.84, P=0.004; TSc vs. TAp: OR=4.12, 95%CI 1.93-8.79, P=0.000 3). There was no statistical difference between the TF and TSc approaches (TF vs. TSc: OR=0.98, 95%CI 0.38-2.51, P=0.97); at 1 year, there was no statistical difference in mortality among the three approaches (P>0.05); at 2 years, there was no statistical difference between TSc and TF or TAp approaches (TF vs. TSc: OR=1.21, 95%CI 0.95-1.54, P=0.13; TSc vs. TAp: OR=1.02, 95%CI 0.76-1.36, P=0.91). (2) The incidence of acute kidney injury after TF approach was lower than that of the TAp approach (OR=0.30, 95%CI 0.22-0.41, P<0.000 01). (3) There was no statistical difference in major vascular complications between TSc and TF or TAp approaches (TF vs. TSc: OR=0.75, 95%CI 0.38-1.49, P=0.41; TSc vs. TAp: OR=1.37, 95%CI 0.56-3.32, P=0.49). (4) There was no statistical difference in severe bleeding events between TF and TSc (OR=0.97, 95%CI 0.53-1.76, P=0.92). (5) There was no statistical difference in the incidence of postoperative stroke, pacemaker dependent block among the three approaches (P>0.05).ConclusionTAp and TSc approaches are safe and effective. They are not only an alternative to TF approach, but also the first choice in some patients with poor condition of iliofemoral artery.

    Release date:2021-07-28 10:02 Export PDF Favorites Scan
  • Transapical transcatheter valve-in-valve implantation treatment for patients with deteriorated mitral bioprosthesis after aortic-mitral double valve replacement

    ObjectiveTo determine the clinical efficacy of transapical transcatheter mitral valve-in-valve treatment for patients with deteriorated mitral bioprosthesis after aortic-mitral double valve replacement.MethodsThe clinical data of 9 patients who underwent transapical transcatheter mitral valve-in-valve implantation after aortic-mitral double valve replacement due to mitral bioprosthesis deterioration from May 2020 to January 2021 in our hospital were retrospectively analyzed, including 4 males and 5 females with a mean age of 72.44±7.57 years.ResultsSurgeries were performed successfully in all patients with no conversion to median sternotomy. The mean procedural time was 101.33±48.49 min, the mechanical ventilation time was 23.11±26.54 h, the ICU stay was 1.89±1.05 d and the postoperative hospital stay was 6.11±2.02 d. Residual mild mitral regurgitation was only observed in 1 patient. Only 1 patient needed postoperative blood transfusion. No major complications were observed in all patients. There was no death in postoperative 90 days.ConclusionFor patients with deteriorated mitral bioprosthesis after aortic-mitral double valve replacement, transapical transcatheter mitral valve-in-valve implantation achieves good clinical results and effectively improves the hemodynamics without increasing the risk of postoperative left ventricular outflow tract obstruction. The surgery is feasible and effective.

    Release date:2021-07-28 10:22 Export PDF Favorites Scan
  • Transapical transcatheter aortic valve replacement for aortic regurgitation in a patient with extremely horizontal aorta

    An 81-year-old male patient was admitted to Guangdong Provincial People's Hospital due to chest distress and shortness of breath after activity for half a year. Examination after admission revealed severe aortic insufficiency, tricuspid aortic valve and extremely horizontal aorta with an aortic root angulation of 99°. The Society of Thoracic Surgeons score was 7%. And taking the strong demand of the patient and his family into consideration, we decided to perform transapical transcatheter aortic valve replacement after multidisciplinary evaluation. The procedure was successfully performed by means of low deployment land zone and traction of pre-exist Prolene suture. Three-month follow-up confirmed the normal function of aortic prosthetic valve without residual regurgitation. This case provides a reference for the interventional treatment in patients with extremely horizontal aorta.

    Release date: Export PDF Favorites Scan
  • Transapical mitral valve repair with LifeClip system: Early outcome of a single center

    ObjectiveTo evaluate the safety and efficacy of transapical mitral valve repair with moderate-to-severe or severe mitral regurgitation (MR) by using LifeClip system. Methods We retrospectively analyzed the clinical data of 7 symptomatic patients with moderate-to-severe or severe MR who received transapical mitral valve repair by using the LifeClip system in our hospital from July to November 2021. There were 5 males and 2 females with an average age of 76.0±7.5 years. ResultsThere were 2 patients with degenerative MR and 5 patients with functional MR. All of the procedures were successful and 6 patients received 1 LifeClip while the other one patient received 2. The operation time was 135.7±46.9 min, the mechanical ventilation time was 12 (3, 14) h, and the hospital stay time was 18.1±4.1 d. No serious complications or death occurred during the perioperative or follow-up period. MR reduction by ≥2 grades was achieved in all the patients at the one-month follow-up. The classification of cardiac function was improved in varying degrees. Conclusion Transapical mitral valve repair using the LifeClip system shows good safety and efficacy for severe MR patients, and MR degree is significantly improved at early follow-up. However, the benefit of LifeClip should be validated in a larger sample size of Chinese population and through long-term follow-up.

    Release date: Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content