west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "罗晓中" 8 results
  • 周围神经缺血再灌注损伤

    Release date:2016-09-01 11:04 Export PDF Favorites Scan
  • EXPERIMENTAL STUDY OF TISSUE ENGINEERED BONE WITH CRYOPRESERVATON ON HEALING OF BONE DEFECTS

    Objective To investigate the effect of tissue engineered bone with cryopreservation on healing of bone defects and to explore feasibility of cryopreservation for tissue engineered bone. Methods Tissue engineeredbones were constructed with osteoblasts being seeded onto bio-derived materials made from freshhuman bones,and they were preserved at 4℃ and -196℃ for 3 months and 6 monthsrespectively.They were applied to repair segmental bone defects of rabbit’s radius while the tissue engineered bone without cryopreservation and bio-derived materials were brought into control groups.The experiment was divided into groups A3,A6,B3,B6,C and D(group A3:tissue engineered bones were preserved at 4℃ for 3 months; group A6:tissue engineered bones were preserved at 4℃ for 6 months;group B3:tissue engineered bones were preserved at -196℃ for 3 months; group B6:tissue engineered bones were preserved at -196℃ for 6 months; group C: tissueengineered bones without cryopreservation; group D: bio-derived materials). Macroscopical and histologial examination were done at the 2nd,4th,6th,12th weeks, X-ray examination was done at the 6th,12th weeks and biomechanics were determined at 12th weeks after operation respectively. Results Macroscopical observation showed no significant differences among group A3, A6, B3, B6 and C, but less new bone formation and more obvious boundary in group D were observed. Histological observation showed more collagen and new bone around the edge of implant of group A3, A6, B3, B6 and C than group D, and histological evaluation showed significant differences between group D and other groups(P<0.05). Radiographic observation showed no absorbability of the implant cortex and less new bone formation in group D, but the unity between implant and host bone, medullary cavity reopened, disappearance of fracture line and fine bone modelling were observed in other groups at 12 weeks after operation. Biomechanics between group D and other groups showed significant differences(P<0.05). Conclusion Cryopreservation (4℃ and -196℃) were capable of preserving tissue engineered bone for long time, and tissue engineered bone withcryopreservation has significant effect on healing of bone defects. The methods f it clinical application.

    Release date:2016-09-01 09:29 Export PDF Favorites Scan
  • 聚髌器结合克氏针固定治疗严重粉碎性髌骨骨折疗效观察

    【摘要】 目的 评价聚髌器结合克氏针内固定治疗严重粉碎性髌骨骨折的临床疗效。 方法 2005年8月-2009年12月,采用聚髌器结合克氏针内固定治疗64例髌骨粉碎性骨折,患部均为新鲜粉碎有移位骨折。 结果 62例获得随访,2例失访。骨折愈合时间6~11周,平均7周。按HSS膝关节评价标准:优33例(53.2%);良21例(33.9%);可6例(9.7%);差2例(3%);优良率为87.1%。术后无内固定松动,发生膝关节创伤性关节炎2例。 结论 聚髌器结合克氏针内固定具有复位满意、固定可靠,有利于早期功能锻炼,是治疗粉碎性髌骨骨折的理想选择方式之一。

    Release date:2016-09-08 09:24 Export PDF Favorites Scan
  • COMPARATIVE STUDY ON FIXATION WITH PERCUTANEOUS CANNULATED SCREWS ASSISTED BY ROBOT NAVIGATION AND CONVENTIONAL SURGERY WITH MANUAL POSITIONING FOR FEMORAL NECK FRACTURES

    Objective To investigate the effectiveness and the advantage of fixation with percutaneous cannulated screws assisted by robot navigation in the treatment of femoral neck fractures by comparing with the conventional surgery. Methods Between January 2013 and December 2014, 20 patients with femoral neck fracture were treated by internal fixation with percutaneous cannulated screws assisted by robot navigation (navigation group), another 18 patients undergoing conventional surgery with manual positioning were chosen as the control group. There was no significant difference in gender, age, cause of injury, the injury side, time from injury to operation, and the classification of fractures between 2 groups (P > 0.05). The operation time, X-ray fluoroscopy time, blood loss, frequency of guide pin insertion, and healing time were recorded. At 1 week after operation, the parallel degree of screws was measured on the anteroposterior and lateral X-ray films; the Harris score was used to evaluate the hip function. Results All incisions of 2 groups healed by first intention after operation. There was no significant difference in operation time between 2 groups (t= -1.139, P=0.262). The blood loss, frequency of guide pin insertion, and X-ray fluoroscopy time of navigation group were significantly less than those of control group (P < 0.05). There were 2 screws penetrating into the joint cavity in control group. The patients were followed up 12-24 months with an average of 18 months. The navigation group got significantly better parallel degree of screws than control group on the anteroposterior and lateral X-ray films (t=25.021, P=0.000; t=18.659, P=0.000). Fractures healed in all patients of navigation group (100%), and the healing time was (21.8±2.8) weeks; fracture healed in 16 patients of control group (88.9%), and the healing time was (24.0 ± 3.7) weeks. There was no significant difference in healing rate and healing time between 2 groups (χ2=2.346, P=0.126; t=1.990, P=0.055). The Harris score of navigation group (87.1±3.7) was significantly higher than that of control group (79.3±4.7) at last follow-up (t= -5.689, P=0.000). Conclusion Cannulated screw fixation assisted by robot navigation is a good method to treat femoral neck fractures, which has the advantages of more accurate positioning, better hip function recovery, less surgical trauma, and shorter X-ray exposure time.

    Release date: Export PDF Favorites Scan
  • Application of three-dimensional printing technology in treatment of internal or external ankle distal avulsed fracture

    ObjectiveTo explore the effectiveness and advantage of three-dimensional (3D) printing technology in treatment of internal or external ankle distal avulsed fracture.MethodsBetween January 2015 and January 2017, 20 patients with distal avulsed fracture of internal or external ankle were treated with the 3D guidance of shape-blocking steel plate fixation (group A), and 18 patients were treated with traditional plaster external fixation (group B). There was no significant difference in gender, age, injury cause, disease duration, fracture side, and fracture type between 2 groups (P>0.05). Recording the fracture healing rate, fracture healing time, the time of starting to ankle functional exercise, residual ankle pain, and evaluating ankle function recovery of both groups by the American Orthopaedic Foot and Ankle Society (AOFAS) score.ResultsAll patients were followed up 8-24 months, with an average of 15.5 months. In group A: all incisions healed by first intention, the time of starting to ankle functional exercise was (14±3) days, fracture healing rate was 100%, and the fracture healing time was (10.15±2.00) weeks. At 6 months, the AOFAS score was 90.35±4.65. Among them, 13 patients were excellent and 7 patients were good. All patients had no post-operative incision infection, residual ankle pain, or dysfunction during the follow-up. In group B: the time of starting to ankle functional exercise was (40±10) days, the fracture healing rate was 94.44%, and the fracture healing time was (13.83±7.49) weeks. At 6 months, the AOFAS score was 79.28±34.28. Among them, 15 patients were good, 2 patients were medium, and 1 patient was poor. During the follow-up, 3 patients (16.67%) had pain of ankle joint with different degrees. There were significant differences in the postoperative fracture healing rate, fracture healing time, the time of starting to ankle functional exercise, and postoperative AOFAS score between 2 groups (P<0.05).ConclusionApplication of 3D printing technology in treatment of internal or external ankle distal avulsed fracture is simple, safe, reliable, and effective. In particular, it is an ideal treatment for avulsed fracture.

    Release date:2018-02-07 03:21 Export PDF Favorites Scan
  • COMPARISON STUDY ON LOCKING COMPRESS PLATE EXTERNAL FIXATOR AND STANDARD EXTERNAL FIXATOR FOR TREATMENT OF TIBIAL OPEN FRACTURES

    Objective To compare the clinical results of locking compress plate (LCP) as an external fixator and standard external fixator for treatment of tibial open fractures. Methods Between May 2009 and June 2012, 59 patients with tibial open fractures were treated with LCP as an external fixator in 36 patients (group A), and with standard external fixator in 23 patients (group B). There was no significant difference in gender, age, cause of injury, affected side, type of fracture, location, and interval between injury and surgery between 2 groups (P gt; 0.05). The time of fracture healing and incision healing, the time of partial weight-bearing, the range of motion (ROM) of knee and ankle, and complications were compared between 2 groups. Results The incidence of pin-track infection in group A (0) was significantly lower than that in group B (21.7%) (P=0.007). No significant difference was found in the incidence of superficial infection and deep infection of incision, and the time of incision healing between 2 groups (P gt; 0.05). Deep vein thrombosis occurred in 5 cases of group A and 2 cases of group B, showing no significant difference (χ2=0.036, P=0.085). All patients were followed up 15.2 months on average (range, 9-28 months) in group A, and 18.6 months on average (range, 9-47 months) in group B. The malunion rate and nonunion rate showed no significant difference between groups A and B (0 vs. 13.0% and 0 vs. 8.7%, P gt; 0.05); the delayed union rate of group A (2.8%) was significantly lower than that of group B (21.7%) (χ2=5.573, P=0.018). Group A had shorter time of fracture healing, quicker partial weight-bearing, greater ROM of the knee and ankle than group B (P lt; 0.05). Conclusion The LCP external fixator can obtain reliable fixation in treating tibial open fracture, and has good patients’ compliance, so it is helpful to do functional exercise, improve fracture healing and function recovery, and reduce the complication incidence.

    Release date:2016-08-31 04:05 Export PDF Favorites Scan
  • EFFECT OF REFORMATIVE ACETABULAR CENTRALIZATION TECHNOLOGY ON LEG-LENGTH INEQUALITY IN TOTAL HIP ARTHROPLASTY

    ObjectiveTo investigate the application value of acetabular centralization technology for correction of leg-length inequality in total hip arthroplasty (THA). MethodsBetween June 2001 and January 2012, 147 cases of abnormal acetabular center were treated. Of them, 68 cases underwent routine THA (control group), and 79 cases underwent acetabular reconstruction by fossae ovalis oriented centralized technology in THA (test group). There was no significant difference in gender, age, side, pathogeny, acetabular rotation center indexs, difference of relative and absolute leg-length, and Harris score between 2 groups before operation (P>0.05). The hip joint function was evaluated by Harris score; the difference of relative leg-length was measured by tape; the difference of absolute leg-length and the horizontal and vertical distances of actual and true rotation center were also measured on the X-ray films by software. ResultsThe patients were followed up 8-26 months (mean, 8.3 months) in the test group, and 6-33 months (mean, 9.7 months) in the control group. Sciatic nerve injury occurred in 2 cases (1 in each group, respectively), lower extremity deep venous thrombosis in 7 cases (3 in test group and 4 in control group), and hip joint dislocation in 2 cases (control group); the other patients had no related complications. The difference of relative leg-length and Harris score in test group were significantly better than in control group (P<0.05), and significant difference was also found when compared with preoperative one in 2 groups (P<0.05). The horizontal and vertical distances of actual and the true rotation center in test group was significantly better than those in control group at immediate after operation on the X-ray films (P<0.05); and significant differences were also found when compared with preoperative ones in 2 groups (P<0.05). At 6 months after operation, the absolute leg-length difference in test group was significantly better than that in control group (P<0.05); and significant difference was also found when compared with preoperative one in 2 groups (P<0.05). ConclusionThe fossae ovalis oriented acetabular centralized technology in THA can significantly correct abnormal hip center of rotation, thus reduce the relative and absolute leg-length inequality and improve the life quality of the patients.

    Release date: Export PDF Favorites Scan
  • Study on development and biomechanics test of plastic rod-hook plate

    ObjectiveTo develop a new type of internal fixation device which can be used to treat the minor avulsion fracture of the medial malleolus, lateral malleolus, the base of the fifth metatarsal, and the ulnar styloid process, and investigate the reliability and effectiveness of the device through biomechanical test.MethodsEighty human’s bone specimens with complete medial malleolus, lateral malleolus, the base of the fifth metatarsal, and the ulnar styloid process were selected and measured the anatomic indexes (the height, width, and thickness of medial malleolus, lateral malleolus, the base of the fifth metatarsal, and the ulnar styloid process). The CT three-dimensional reconstruction data of 200 healthy adults which including medial malleolus, lateral malleolus, the base of the fifth metatarsal, and the ulnar styloid process was also selected and measured the anatomic indexes by Mimics software. The plastic rod-hook plate was designed according to the measured results and prepared. Forty fresh porcine lower limb specimens were randomly divided into groups A and B (20 in each group), and 8 adult lower limb specimens including 4 left and 4 right were also randomly divided into groups A and B (4 in each group). All specimens were prepared for avulsion fracture of medial malleolus. Then, the fractures were fixed with plastic rod-hook plate in group A and wire anchor in group B. The load and axial torsion test of ankle joint were carried out by universal biomechanical testing machine.ResultsAccording to the anatomical characteristics, a plastic rod-hook plate was designed successfully. The biomechanical test results between animal and human specimens were consistent. There was a linear relationship between load and displacement in the ankle distal load test. The displacement when loaded to the maximum load was significantly lower in group A than in group B (P<0.05). The torsion angle and torque were significantly higher in group A than in group B when the internal fixation failed in the axial torsion test of the ankle joint (P<0.05), and the torsion angle was significantly smaller in group A than in group B when the torque was 1 N·m (P<0.05), and the maximum torque was also significantly higher in group A than in group B (P<0.05). However, there was no significant difference in torsion angle between the two groups in the maximum torque (P>0.05).ConclusionThe biomechanical properties of plastic rod-hook plate is obviously better than wire anchor, and the fixation of avulsion fracture with plastic rod-hook plate is easy to operate, which is expected to be used in the clinical treatment of minor avulsion fractures such as medial malleolus, lateral malleolus, base of the fifth metatarsal, and ulna styloid process.

    Release date:2019-11-21 03:35 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content