Objective To compare the outcomes between intramedullary nail change and augmentation plating with a retained intramedullary nail for aseptic nonunion of femoral shaft fractures after femoral nailing, and to analyze the cause so as to guide the clinical application. Methods Between June 2001 and June 2011, 28 patients with aseptic nonunion of femoral shaft fractures after femoral nailing were treated with intramedullary nail change (11 patients, group A) and augmentation plating with a retained intramedullary nail (17 patients, group B), and the clinical data were analyzed retrospectively. There was no significant difference in age, gender, smoking, location of fracture, Association for the Study of Internal Fixation (AO/ASIF) classification, type of injury, associated injury, type of nonunion, and time of nonunion between 2 groups (P gt; 0.05). The patients were followed up by imaging and the clinical function at regular intervals to observe the callus growth and the recovery condition of the affected limb function, and clinical curative effectiveness was evaluated by Tohner-Wrnch standard. Results The operation time, intraoperative bleeding volume, and intraoperative erythrocyte-transported volume in group A were significantly higher than those in group B (P lt; 0.05). There was no significant difference in postoperative drainage volume and hospitalization days between 2 groups (P gt; 0.05). All the incisions healed by first intention, and no nerve and blood vessel injury occurred. All patients were followed up 18.6 months on average (range, 12-36 months). All cases obtained bone union, and time of clinical and radiological bone healing in group B was significantly shorter than those in group A (P lt; 0.05). During follow-up, no following complication occurred: deep incision infection, injuries of blood vessels and nerves, loosening and breakage of internal fixation, loss of reduction, angulated and rotational malunion. According to Tohner-Wrnch standard at last follow-up, the results were excellent in 6 cases, good in 3 cases, and poor in 2 cases, with an excellent and good rate of 81.8% in group A; the results were excellent in 12 cases, good in 5 cases, with an excellent and good rate of 100% in group B; and difference was significant between 2 groups (Z= — 2.623, P=0.021). Conclusion Augmentation plating with a retained intramedullary nail is an ideal treatment for aseptic nonunion of femoral shaft fractures after femoral nailing and can achieve satisfactory clinical outcomes because it has simpler operation, shorter operation time, less blood loss, and less trauma than intramedullary nail change.
Objective To compare the effectiveness of proximal femoral nail antirotation (PFNA) and reconstruction nail with minimally invasive technique for ipsilateral femoral shaft and extracapsular hip fractures in young and middle-aged patients. Methods Sixty-nine young and middle-aged patients with ipsilateral femoral shaft and extracapsular hip fractures were treated between January 2000 and August 2010, and their data were analyzed retrospectively. Of them, fractures were fixed by reconstruction nail in 44 cases (reconstruction nail group) and by PFNA in 25 cases (PFNA group). There was no significant difference in gender, age, weight, injury cause, fracture type, or disease duration between 2 groups (P gt; 0.05). The operation time, blood loss, fracture healing time, complications, and functional outcomes were compared between 2 groups to evaluate the effectiveness. Results The operation time and blood loss in the PFNA group were significantly less than those in the reconstruction nail group (P lt; 0.05). The follow-up time was 12-38 months (mean, 20 months ) in the PFNA group and was 12-48 months (mean, 22 months) in the reconstruction nail group. No complication occurred as follows in 2 groups: wound infection, deep venous thrombosis, pulmonary embolism, breakage of the implants, avascular necrosis of the femoral head, or serious rotation and shortening deformity of lower limbs. In the PFNA group and the reconstruction nail group, 1 patient underwent technical difficulty in nail implant and 7 patients underwent technical difficulty in proximal locking screw, respectively; 3 patients and 6 patients had intra-operative iatrogenic fracture of femoral shaft, respectively; and delayed union of femoral shaft was observed in 1 patient and 2 patients, respectively. The complication rate was 20% (5/25) in the PFNA group and 34% (15/44) in the reconstruction nail group, showing no significant difference (χ2=1.538, P=0.215). No significant difference was found in fracture healing time between 2 groups (P gt; 0.05). At last follow-up, there was no significant difference in Harris hip score and Evanich knee score between 2 groups (P gt; 0.05). Conclusion PFNA or reconstruction nail with minimally invasive technique is a good method to treat ipsilateral femoral shaft and extracapsular hip fractures, but the PFNA is superior to the reconstruction nail because of simple operation.
【Abstract】 Objective The auto-control micro-motion intramedullary locking nail (AMLN) is designed, to reducethe incidence of delayed union and non-union of femoral shaft fractures fixed by interlocking intramedullary nails, and toobserve the cl inical effect of self-design AMLN in the treatment of femoral shaft fractures. Methods The distal and promixalnails were connected by the micro-motion locking structure, which could cause 1.0-1.5 mm axial micro-motion between fracture gaps. It could produce physical stimulus and conduction between fracture gaps in the course of fracture union. From December 2003 to May 2006, 32 cases of femoral shaft fractures were treated with AMLN, including 21 males and 11 females with the average age of 31.2 years (ranging from 20 years to 43 years). The trauma resulted from fall wounds in 3 cases, crash injuries in 1 case and car accidents in 28 cases. Twenty-nine cases were fresh fractures in different parts of the femoral shaft with transverse, obl ique, spiral and comminuted fractures of type I, II, III and IV. Three cases were old non-union fractures. The fresh fractures were treated by closed AMLN fixation, while the old fractures were treated by open AMLN nails after routine implantation of self bone. Results All the 32 cases were followed up for the average time of 11.5 months (rangeing from 8 months to 22 months). The X-ray films showed the fractures were healed 4.0 to 7.5 months after the operation, with the mean time of 5.1 months, and no break of the nail happened. One nail mildly bent in the comminuted fracture, and 2 patients felt sl ightly unwell at the needl ing point. According to the Klemm criterion for function, 26 cases were excellent, 5 good, 1 fair, and the choiceness rate was 96.88%. Conclusion With a suitable design, AMLN is easy to perform and helpful to quicken fracture union, and it is effective to treat femoral shaft fractures.
【Abstract】 Objective To discuss the techniques and advantages of closed reduction and intramedullary nail ing intreating femoral shaft fracture without cannulated femoral reamer. Methods From January 2006 to June 2007, 24 cases offemoral shaft fracture were treated with closed reduction and intramedullary nail ing. Among them, there were 14 males and 10 females, with the average age of 38.3 years (ranging from 18 years to 63 years), with 7 left legs and 17 right legs. The average course of the disease was 7.6 days (ranging from 3 days to 20 days). According to the AO typing, there were 5 cases of type A, 6 of type B, 7 of type C1, 2 of type C2 and 4 of type C3. Closed reduction was achieved with manipulation and reaming of femoral canal was instructed by fluoroscopy. Results The operation time lasted from 100 minutes to 170 minutes, with the average time of 128.3 minutes. One patient was given a transfusion of 400 mL, and others were not. Twenty cases were followed up with the average time of 13.1 months (ranging from 6 months to 24 months). A mild to large amount of bony callus was showed on X-ray films 6 to 12 weeks postoperatively. Walking without crutches began at the average week of 22.2 (ranging from 15 to 30) postoperatively. Range of motion of the knee was 0° to 145.5°. No infection or break of the internal fixator occurred. Myositis ossificans with pain and insufficient flexion of hip (120°) happened in 1 case and the pain disappeared after non-steroid anti-inflammatory drugs were taken. Nonsymptomatic myositis ossificans occurred in 2 cases and no treatment was needed. Conclusion Closed reductionand intramedullary nail ing can help to protect the blood supply of fracture fragments and provide central fixation. The operation process will be more compl icated if cannulated femoral reamer is not available.
Objective To describe the design and application of a new intramedullary controlled dynamic nailing(ICDN).〓〖WTHZ〗Methods The new ICDN was made of a stainlesssteel alloy, consists of a nail shaft, innerrod, tensile screw, end cape and two interlocked screws. From December 2005 toFebruary 2007, 48 cases of femoral shaft fractures were treated with ICDN. There were 16 females and 32 males with a mean age of 36.6 years (range, 16-48years). Injury was caused by traffic accident in 26 cases, falling from a height in14, sportsrelated in 7 and crush injury in 1 case. According to Winquist classification, Thirtyseven cases were classified as typeⅠ(13 cases of typeⅠ-1,23 cases of Ⅰ-2 and 1 case of Ⅰ-3), eleven as type Ⅱ fracture ( 2 cases oftype Ⅱ-1, 8 cases of Ⅱ-2 and 1 case of Ⅱ-3). The time from injury to admission was an hour to a week. Emergency operation was performed in 19 cases and the other 29 patients were given operation within 3 days. Results All cases were followed up for an average of 5 months (3-12 months). Among them, the average healing period was 21 weeks (826 weeks) and no nonunion, delayed union and breakage of nailings occurred. The complications included 2 infections, 5 pains, and 4 deformities. Based on Johner and Wrubs standard, the results were excellent in 39 cases, good in 7 cases and fair in 2 cases, The excellent and good rate was 95.8%. Conclusions ICDN has excellent biomechanical characteristics which can provide a flexible fixation in treating femoral shaft fractures. The operation is simple and is one of the good techniquesin treating femoral shaft fractures.
The treatment of open reduction and internal fixation was carried out in 480 cases of fractures offemoral shafts. Patients were followed up in an average of 7. 6 years, 50 cases, rate of occurrence of10. 4%, had varying degrees of functional impairment of knee. It was considered that thecharacteristics of fractures, the time of oporation , selection of incision , the types of internal fixationdevices, and the duration of external immobilization were the main causes related to the occurren...