west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "胫骨止点撕脱骨折" 9 results
  • ARTHROSCOPICALLY ASSISTED TREATMENT OF ACUTE TIBIAL INSERTION AVULSION FRACTURE OF POSTERIOR CRUCIATE LIGAMENT VIA POSTEROMEDIAL INCISION

    Objective To investigate the effectiveness of arthroscopically assisted treatment of acute tibial insertion avulsion fracture of the posterior cruciate ligament (PCL) via posteromedial incision. Methods Between January 2010 and January 2012, 22 patients with acute tibial insertion avulsion of the PCL underwent arthroscopic reduction and fixation via posteromedial incision. There were 14 males and 8 females with an average age of 32 years (range, 18-48 years). The injury causes included traffic accident injury in 14 cases, sport injury in 4 cases, and falling injury in 4 cases. The disease duration ranged from 7 to 16 days (mean, 10 days). Of 22 patient, 14 had simple PCL injury, 6 had PCL injury with meniscus injury, and 2 with cartilage injury. The results of posterior drawer test were positive in all patients. The preoperative Lysholm score was 51.1 ± 3.4. Results All incisions healed by first intention without infection, deep venous thrombosis of lower limbs, or vessel and nerve injuries. All patients were followed up 12-24 months (mean, 18.4 months). X-ray films showed that all fractures healed with the healing time of 2-4 months (mean, 3 months). The Lysholm score was improved to 96.0 ± 2.2 at 6 months after operation, showing significant difference when compared with preoperative score (t=43.020, P=0.000). Conclusion Arthroscopically assisted treatment of acute tibial insertion avulsion fracture of the PCL via posteromedial incision is a safe, easy, and effective method.

    Release date:2016-08-31 04:07 Export PDF Favorites Scan
  • EFFECTIVENESS OF ARTHROSCOPIC TREATMENT OF ANTERIOR CRUCIATE LIGAMENT TIBIAL EMINENCE AVULSION FRACTURE WITH NON-ABSORBABLE SUTURE FIXATION COMBINED WITH MINI-PLATE

    Objective To evaluate the surgical techniques and effectiveness of arthroscopic treatment of anterior cruciate ligament (ACL) tibial eminence avulsion fracture with non-absorbable suture fixation combined with the mini-plate. Methods Between January 2009 and March 2012, 32 patients with ACL tibial eminence avulsion fractures were treated. There were 18 males and 14 females, aged 12-40 years (mean, 17.5 years). The injury causes included traffic accident injury in 15 cases, sport injury in 6 cases, and falling injury in 11 cases. The time from injury to operation ranged 7-18 days with an average of 9.5 days. Before operation, the results of Lachman test were all positive; the Lysholm score was 52.13 ± 4.22 and the International Knee Documentation Committee (IKDC) score was 44.82 ± 2.44. According to Meyers-McKeever classification criteria, there were 12 cases of type II and 20 cases of type III. After arthroscopic poking reduction of fracture, tibial eminence avulsion fractures were fixed with the Ethibond non-absorbable sutures bypass figure-of-eight tibial tunnel combined with the metacarpal and phalangeal mini-plate. Results Primary healing was obtained in all incisions; no joint infection or skin necrosis occurred after operation. All patients were followed up with an average time of 22.4 months (range, 12-50 months). The patients showed negative Lachman test at 12 weeks after operation. Except 3 patients having knee extension limitation at last follow-up, the knee extension range of motion (ROM) was normal in the other patients; the knee flexion ROM was normal in all patients. The Lysholm score and IKDC score were significantly improved to 94.19 ± 0.93 and 94.35 ± 1.22 at last follow-up, showing significant differences when compared with preoperative values (t=55.080, P=0.000; t=101.715, P=0.000). Conclusion The arthroscopic treatment of ACL tibial eminence avulsion fracture with Ethibond non-absorbable suture fixation combined with mini-plate is an effective procedure with the advantages of minimal trauma, reliable fixation, and satisfactory recovery of the knee joint function.

    Release date:2016-08-31 04:12 Export PDF Favorites Scan
  • 关节镜下平行丝线法治疗前交叉韧带撕脱骨折

    【摘 要】 目的 总结和分析关节镜下套管针引导平行丝线固定法修复前交叉韧带胫骨止点撕脱骨折的手术方法和疗效。 方法 2001 年1 月- 2005 年12 月,收治前交叉韧带胫骨止点撕脱骨折17 例,其中男12 例,女5 例;年龄11 ~ 48 岁。新鲜骨折14 例,陈旧骨折3 例。按Meyers-Mckeever 分型,Ⅱ型5 例,Ⅲ A 型8 例,Ⅲ B 型4 例,术前Lysholm 膝关节功能评分57.3 分。术后在支具保护下行功能锻炼,定期随访,摄X 线片,观察、测量关节活动度及关节稳定性,术后行Lysholm 膝关节功能评分。 结果 全部获随访6 ~ 28 个月,平均12.7 个月。膝关节活动度恢复正常者13 例;不同程度受限3 例,但关节活动度均超过100º,为伴内侧副韧带损伤者;1 例陈旧骨折患者,术后过早去除支具功能锻炼,骨折未愈合,关节不稳,1 年后二次行前交叉韧带重建术,效果满意。16 例术后6 个月复查,X 线片示均解剖复位并骨折愈合,无关节不稳;Lysholm 评分97.8 分。 结论 关节镜下利用2 条平行线固定法治疗前交叉韧带胫骨止点撕脱骨折,对前交叉韧带及骨块损伤小,骨折复位简便,固定范围广且可靠,应力承载面积大,受力均匀,能防止骨折块碎裂、旋转或上撬。

    Release date:2016-09-01 09:09 Export PDF Favorites Scan
  • EFFECTIVENESS OF MINI INCISION AND ABSORBABLE SCREW FIXATION FOR TREATMENT OF ANTERIOR CRUCIATE LIGAMENT TIBIAL EMINENCE AVULSION FRACTURE

    ObjectiveTo investigate the effectiveness of open reduction by mini incision and absorbable screw internal fixation for the treatment of anterior cruciate ligament (ACL) tibial eminence avulsion fracture. MethodsBetween January 2006 and July 2012, 90 patients (90 knees) with ACL tibial eminence avulsion fracture were treated. There were 58 males and 32 females, aged from 10 to 58 years with an average of 33.7 years. The causes of injury were traffic accident injury in 60 cases, sports injury in 22 cases, and falling injury in 8 cases. The disease duration was 1-365 days with a median of 106 days. Combined injuries included 14 cases of meniscus injury, 5 cases of medial collateral ligament injury, and 3 cases of avulsion fracture of the anterior horn of the lateral meniscus. All patients underwent open reduction by mini incision and internal fixation with absorbable screw. Postoperative rehabilitation exercise was performed. ResultsTwo patients had delayed healing of incision, and others obtained primary healing. All the patients were followed up 6-72 months (mean, 40.1 months). X-ray examination showed that bone union was achieved in all patients at 3-12 months after operation; nail tail came off in 7 cases at 4-13 months after operation, and the nail tail was taken out under arthroscopy. At 6-12 months after operation, the range of motion (ROM), Tegner score, Lysholm score, and International Knee Documentation Committee (IKDC) score were significantly increased when compared with preoperative ones (P < 0.05). ConclusionA combination of open reduction by mini incision and absorbable screw internal fixation for the treatment of ACL tibial eminence avulsion fracture has the advantages of easy operation, firm fixation, and satisfactory functional rehabilitation, so it is a safe and effective method for the treatment of ACL tibial eminence avulsion fracture.

    Release date: Export PDF Favorites Scan
  • EFFECTIVENESS OF ARTHROSCOPIC ULTRA-Braid SUTURE PLANE FIXATION FOR ANTERIOR CRUCIATE LIGAMENT TIBIAL EMINENCE AVULSION FRACTURES

    ObjectiveTo investigate the surgical technique and effectiveness of arthroscopic ULTRA-Braid suture plane fixation for anterior cruciate ligament (ACL) tibial eminence avulsion fractures. MethodsBetween June 2012 and October 2014, 16 cases of ACL tibial eminence avulsion fracture were treated with ULTRA-Braid suture plane fixation under arthroscopy. There were 10 males and 6 females, aged from 17 to 38 years (mean, 25.8 years). The left knee was involved in 5 cases and the right knee in 11 cases. The causes were traffic accident injury in 9 cases, falling from height injury in 4 cases, and sports injury in 3 cases. The average interval from injury to operation was 7 days (range, 5-10 days) except 1 patient who received operation at 6 weeks after injury. The knee joint swelling was obvious; the result of Lachman test was positive; and the knee joint Lysholm score was 45.38±9.87. According to classification standard introduced by Meyers-McKeever-Zaricznyj, 7 cases were rated as type Ⅱ, 8 cases as type Ⅲ, and 1 case as type Ⅳ, excluding ligament and meniscus injury. ResultsAll the incisions healed by first intention. The patients received follow-up of 6-18 months (mean, 10 months). The postoperative X-ray and CT showed anatomic reduction (12 cases) or near anatomic reduction (4 cases); all fractures healed at 6 months after operation. The result of Lachman test was negative in the other 15 patients except 1 patient (Ⅱ degree). One patient had slight knee pain at 6 months postoperatively, and pain symptom disappeared after 1 year; the other cases resumed daily activities. Lysholm score at last follow-up was 98.13±2.34, showing significant difference when compared with preoperative score (t=-20.801, P=0.000). ConclusionArthroscopic ULTRA-Braid suture plane fixation for ACL tibial eminence avulsion fractures is an effective procedure with the advantages of minimal trauma, reliable fixation, satisfactory functional recovery, and simultaneously avoiding the second surgery.

    Release date: Export PDF Favorites Scan
  • 自制齿状钩钢板治疗后交叉韧带胫骨止点撕脱骨折

    目的总结自制齿状钩钢板治疗后交叉韧带(posterior cruciate ligament,PCL)胫骨止点撕脱骨折的疗效。 方法2012 年 11 月—2016 年 4 月,采用自制齿状钩钢板治疗 PCL 胫骨止点撕脱骨折 11 例。其中男 6 例,女 5 例;年龄 37~63 岁,平均 48.5 岁。致伤原因:交通事故伤 4 例,高处坠落伤 2 例,跌伤 5 例;均为新鲜骨折,受伤至手术时间 3~11 d,平均 5.2 d。骨折按 Meyer-McKeever 分型:Ⅱ型 4 例,Ⅲ型 7 例。术前膝关节屈曲活动度 40~90°,平均 65.9°。术前 Lysholm 评分 50~69 分,平均 58.5 分。 结果术后切口均Ⅰ期愈合。11 例患者均获随访,随访时间 6~20 个月,平均 11 个月。术后 3 个月 X 线片示患者骨折均愈合,骨折端无明显移位。术后 6 个月,患肢膝关节屈曲活动度达 115~130°,平均 121.8°;膝关节后抽屉试验均呈阴性,未见膝关节伸直功能障碍及腘窝部血管、神经损伤并发症;Lysholm 评分为 85~99 分,平均 92.8 分。 结论自制齿状钩钢板治疗 PCL 胫骨止点撕脱骨折可行,操作简便、固定效果可靠,术后疗效满意。

    Release date:2017-06-15 10:04 Export PDF Favorites Scan
  • Suture-bridge fixation under arthroscopy in treatment of tibial eminence avulsion fracture of anterior cruciate ligament in adolescents

    Objective To explore effectiveness of suture-bridge fixation under arthroscopy in treatment of tibial eminence avulsion fracture of anterior cruciate ligament in adolescents. Methods Between June 2013 and October 2016, 18 adolescent patients suffered from tibial eminence avulsion fracture of anterior cruciate ligament were treated by suture-bridge fixation under arthroscopy. There were 11 males and 7 females with an average age of 12.5 years (range, 5-17 years). The injury caused by bruise in 6 cases, by sprain in 4 cases, and by sport injury in 8 cases. The interval between injury and admission ranged from 2 hours to 10 months (median, 2 months). The results of preoperative Lachman and anterior drawer tests were positive. There were 10 cases of knee pain, 4 cases of knee extension limitation, and 4 cases of knee extension without strength. According to the Meyer-McKeever classification criteria, 12 cases were type Ⅱ and 6 cases were type Ⅲ. Results All incisions healed by first intention. All 18 patients were followed up 10-18 months after operation, with an average of 12 months. Postoperative X-ray films showed that all fractures healed after 6-12 weeks (mean, 8 weeks). The results of postoperative Lachman and anterior drawer tests were negative. At last follow-up, the Lysholm knee score was 90.1±5.0 and 93.1±6.2 for affected and unaffected sides, respectively, showing no signifi cant difference (t=0.669, P=0.184). There was no premature closure of skeleton or leg length discrepancy deformity. Conclusion For tibial eminence avulsion fracture of anterior cruciate ligament in adolescents, the suture-bridge fixation under arthroscopy is an effective method with many advantages, such as minimal invasion, reliable fixation, good fracture healing, and no need for second operation to remove implants.

    Release date:2018-10-31 09:22 Export PDF Favorites Scan
  • Effectiveness analysis of minimally invasive safe approach to knee joint for treatment of avulsion fractures of tibial insertion of posterior cruciate ligament

    Objective To analyze the effectiveness of minimally invasive safe approach of the knee joint in the treatment of avulsion fractures of the tibial insertion of the posterior cruciate ligament (PCL). Methods The clinical data of 26 patients with avulsion fractures of tibial insertion of PCL treated with open reduction and internal fixation via minimally invasive safe approach of the knee joint between February 2019 and March 2022 were analyzed retrospectively. There were 18 males and 8 females with an average age of 45.5 years (range, 33-58 years). The causes of injury were traffic accident in 14 cases, falling from height in 7 cases, and sports injury in 5 cases. There were 15 cases of left knee and 11 cases of right knee. The preoperative Lysholm score of knee joint was 34.4±7.3 and the flexion range of motion of knee joint was (69±12)°. According to Meyers classification, there were 8 cases of type Ⅱ and 18 cases of type Ⅲ. The time from injury to operation ranged from 1 to 5 days, with an average of 2 days. ResultsThe operation time was 40-70 minutes, with an average of 55 minutes; the intraoperative blood loss was 10-30 mL, with an average of 15 mL. Delayed incision healing occurred in 1 case after operation, and the incision healed after conservative treatment, and the incisions of the other patients all healed by first intention. Postoperative X-ray films showed satisfactory fracture reduction. All 26 patients were followed up 3-30 months, with an average of 22 months. No complication such as neurovascular injury, infection, and knee extension disorder occurred after operation. X-ray films at 3 months after operation showed that all fractures healed without displacement of the fracture ends; the posterior drawer test was negative. At last follow-up, the flexion range of motion of knee joint was (120±9)°, the Lysholm score was 90.7±3.8, which were significantly improved when compared with those before operation (t=16.376, P<0.001; t=47.665, P<0.001). Conclusion The minimally invasive safe approach of the knee joint for the treatment of PCL tibial insertion avulsion fractures is easy to operate, with minimal surgical trauma, safe and reliable approach, and satisfactory recovery of knee joint function after operation.

    Release date: Export PDF Favorites Scan
  • Treatment of tibial insertion avulsion fracture of anterior cruciate ligament involving anterior root of lateral meniscus with multi-point fixation with anchor and suture

    ObjectiveTo investigate the effectiveness of arthroscopic multi-point fixation with anchor and suture in the treatment of tibial insertion avulsion fracture of anterior cruciate ligament (ACL) involving the anterior root of lateral meniscus (LM). Methods A retrospective analysis was conducted on the clinical data of 28 patients with tibial insertion avulsion fracture of ACL involving the anterior root of LM who were treated with arthroscopic multi-point fixation with anchor and suture between October 2017 and January 2023. There were 12 males and 16 females with the mean age of 26 years (range, 13-57 years). There were 20 cases of sports injury and 8 cases of traffic accident injury. In 2 cases of old fracture, the time from injury to operation was 45 days and 90 days, respectively; in 26 cases of fresh fracture, the time from injury to operation was 3-20 days (mean, 6.7 days). According to the Meyers-McKeever classification, there were 4 cases of type Ⅱ, 11 cases of type Ⅲ, and 13 cases of type Ⅳ. The preoperative Lysholm knee function score was 42.1±9.0, the International Knee Documentation Committee (IKDC) score was 40.0±7.3, and the Tegner score was 0.7±0.7. ResultsAll operations were successfully completed, and the incisions healed by first intention. All the 28 patients were followed up 5-60 months (mean, 20.4 months). During the follow-up, there was nocomplication such as infection, vascular or nerve injury, loosening or breakage of internal fixator, or stiffness of knee joint. Postoperative X-ray films showed satisfactory fracture reduction and firm fixation. All fractures healed clinically, and the healing time was 8-16 weeks (mean, 10.3 weeks). At last follow-up, Lachman test and anterior drawer test were negative. At last follow-up, Lysholm knee function score was 92.4±5.5, IKDC score was 91.6±4.4, and Tegner score was 5.2±1.1, which significantly improved when compared with preoperative scores (t=−22.899, P<0.001; t=−29.870, P<0.001; t=−19.979, P<0.001). ConclusionMulti-point fixation with anchor and suture in the treatment of tibial insertion avulsion fracture of ACL involving the anterior root of LM can not only fix the LM, but also effectively reduce and fix the avulsion fracture, which can obtain good effectiveness.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content