west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "胸主动脉腔内修复术" 14 results
  • EFFECTIVENESS EVALUATION OF THORACIC ENDOVASCULAR AORTIC REPAIR FOR BLUNT THORACIC AORTIC INJURY WITH HOSTILE STENT-GRAFT PROXIMAL LANDING ZONE

    ObjectiveTo explore the effectiveness of thoracic endovascular aortic repair (TEVAR) for blunt thoracic aortic injury (BTAI) with hostile stent-graft proximal landing zone. MethodsA retrospective analysis was made on the clinical data of 13 patients with BTAI with hostile stent-graft proximal landing zone treated by TEVAR between December 2007 and December 2014. There were 10 males and 3 females with the mean age of 44 years (range, 24-64 years). The imaging examination indicated Stanford type B aortic dissection in 7 cases, pseudoaneurysm in 3 cases, aneurysm in 1 case, and penetrating ulcer in 2 cases. According to the partition method of thoracic aortic lesion by Mitchell, 8 cases underwent stent-graft with left subclavian artery (LSA) coverage, 3 underwent chimney stents for LSA, and 2 for left common carotid artery (LCCA). In 2 cases receiving chimney TEVAR involving LCCA, one underwent steel coils at the proximal segment of LSA to avoid type II endoleak and the other underwent in situ fenestration for endovascular reconstruction of LSA. ResultsAll TEVAR procedures were successfully performed. The mean operation time was 1.8 hours (range, 1-3 hours); the mean intraoperative blood loss was 120 mL (range, 30-200 mL); and the mean hospitalization time was 15 days (range, 7-37 days). No perioperative death and paraplegia occurred. The patients were followed up 3-30 months (mean, 18 months). Type I endoleak occurred in 1 case during operation and spontaneously healed within 6 months. Hematoma at brachial puncture site with median nerve compression symptoms occurred in 1 case at 3 weeks after operation; ultrasound examination showed brachial artery pseudoaneurysm and thrombosis, and satisfactory recovery was obtained after pseudoaneurysmectomy. No obvious chest pain, shortness of breath, left upper limbs weakness, numbness, and dizziness symptoms were observed. Imaging examination revealed that stentgraft and branched stent remained in stable condition. Meanwhile the blood flow was unobstructed. No lesions expanded and ruptured. No new death, bacterial infection, or other serious complications occurred. ConclusionAccording to Mitchell method, individualized plan may be the key to a promising result. More patients and further follow-up need to be included, studied, and observed.

    Release date: Export PDF Favorites Scan
  • 对腔内修复Stanford B型主动脉夹层手术范围的质疑——应将“远端旷置”改为“全程修复”

    Release date: Export PDF Favorites Scan
  • 降主动脉“逆行”去分支与主动脉腔内修复术杂交治疗 Stanford A 型主动脉夹层

    Release date:2017-09-26 03:48 Export PDF Favorites Scan
  • Repair of type Ⅰa endoleak after thoracic endovascular aortic repair

    Objective To retrospectively review our experience of correction of type Ⅰa endoleak after thoracic endovascular aortic repair(TEVAR). Methods From August 2009 to May 2016, 29 patients with type Ⅰa endoleak after TEVAR (25 males, 4 females at mean age of 56±10 years (range, 41–86 years) underwent treatment: open surgery in 15 patients (an open surgery group), hybrid aortic arch repair in 6 patients (a hybrid group) and cuff extension in 8 patients(a cuff group). A history of hypertension was noted in 25 patients, diabetes mellitus in 3 patients, coronary artery disease in 3 patients, lung infection in one patient, aortic root aneurysm in one patient and aberrant right subclavian artery in one patient. Results In the open surgery group, no death was observed. Continuous renal replacement therapy and re-intubation was done in one patient and drainage of pericardial effusion in one patient. No death was noted in the hybrid group and persistent type Ⅰa endoleak in one patient. In the cuff group, thrombosis of the left common artery was noted in one patient and bypass of the left axillary artery to the left axillary artery and the left common carotid artery was done. Unfortunately, he died of cerebral infarction and total in-hospital death rate was 3.4% (1/29). Bypass of the left axillary artery to the left axillary artery was done in one patient with left upper limb ischemia. There were 4 (14.2%) deaths during follow-up: 3 deaths in the open surgical group and one death in the cuff group. Endoleak was observed in one patient in the hybrid group and one in the cuff group. Conclusion The corresponding procedure, including open surgery, hybrid aortic arch repair or cuff extension, is scheduled to be done according to the characteristics of type Ⅰa endoleak. Satisfactory outcomes are achieved in patients with typeⅠa endoleak.

    Release date:2018-09-25 04:15 Export PDF Favorites Scan
  • Stanford B 型主动脉夹层腔内修复术后并发 A 型夹层的外科治疗

    目的总结 Stanford B 型主动脉夹层胸主动脉腔内修复术(TEVAR)后并发 A 型夹层的临床特点及外科治疗经验。方法自 2013 年 11 月至 2018 年 3 月,南京鼓楼医院外科治疗 Stanford B 型主动脉夹层 TEVAR 术后并发的 A 型夹层患者 14 例,其中男 13 例 、女 1 例,年龄 24~66(52±3)岁,合并高血压 13 例,糖尿病 2 例,马方综合征 1 例。所有患者在深低温停循环选择性脑灌注下施行手术,近心端 13 例行升主动脉置换术,1 例行 Bentall 术。共实施全弓置换加象鼻手术 13 例,弓部开窗支架植入术 1 例。结果全组无死亡,1 例术后右上肢单瘫,1 例术后血行感染,1 例出现右侧偏瘫及肾功能不全行肾脏替代治疗。随访 6~45 个月,随访期间 1 例患者术后 1 个月因原介入支架远端胸降主动脉发生新的夹层再次行 TEVAR,其余患者 CT 血管造影检查未见吻合口造影剂渗漏及人工血管扭曲。结论B 型主动脉夹层 TEVAR 术后并发 A 型夹层及时给予外科手术治疗可取得良好疗效。

    Release date:2019-07-17 04:28 Export PDF Favorites Scan
  • "J. D" technique: A method for in situ fenestration of left subclavian artery in thoracic endovascular aortic repair

    ObjectiveTo report a simple and safe method for in situ fenestration of left subclavian artery in thoracic endovascular aortic repair (TEVAR).MethodsTwenty-eight patients received in situ fenestration of left subclavian artery in TEVAR from June 2018 to May 2019 in our center, including 23 males and 5 females at an average age of 57.7±9.6 years. Among them, 12 patients used adjustable sheath or guiding catheter (a group A) and 16 patients used "J. D"technique (a group B). The clinical efficacy of the two groups was compared.ResultsIn the group A, 1 patient failed to receive fenestration and was transferred to the chimney technique. In the group B, 1 patient due to the traction system shift during operation, was completed by traditional adjustable sheath puncture. The group B had shorter alignment-perforation time and trigger time and less complications. There was no significant difference in endoleak during short-term follow-up between the two groups.ConclusionThe "J. D" technique is simple, safe and easy to obtain materials. It effectively reduces the risk caused by difficult sheath alignment during the in situ fenestration of the left subclavian artery. Although the results of recent follow-up are not significantly different from traditional methods, it still needs to accumulate the cases to observe the possible risks and difficulties.

    Release date:2020-04-26 03:44 Export PDF Favorites Scan
  • Treatment strategy selection of Marfan syndrome combined with thoracoabdominal aortic diseases

    ObjectiveTo summarize the surgical treatment plan and experience of patients with Marfan syndrome complicated with Stanford type B aortic dissection, and to explore the treatment strategy selection.MethodsA retrospective analysis was conducted on 27 patients with Marfan syndrome complicated with thoracoabdominal aortic diseases who were treated in the department of cardiovascular surgery of our hospital from January 2013 to June 2019, including 13 males and 14 females, with an average age of 32.2±8.6 years. According to the patients' conditions, 19 of them received single pump-assisted blood transfusion combined with total thoracoabdominal aortic replacement (TAAAR), and 8 received thoracic endovascular aortic repair (TEVAR) in critically ill and pregnant patients. The patients were followed up in the outpatient clinic, and the thoracoabdominal aortic CT angiography was reexamined at 3 months, 6 months, 12 months and annually. The outcome of surgery, the incidence of intermediate cardiovascular adverse events, defined as the reoperation due to aortic or cardiac diseases, and intermediate survival rate were studied.ResultsAll 27 patients successfully completed the operation, the operation time was 60-852 (395.10±222.60) min, the spinal cord ischemia time was 14-26 (19.33±3.44) min, and the abdominal viscera ischemia time was 16-23 (19.83±1.94) min. Eight patients of TEVAR were all operated in acute phase and 19 patients of TAAAR in chronic phase. Two early postoperative deaths occurred in TEVAR patients. One died of puerperal infection and multiple organ dysfunction after cesarean section at the same time. After TEVAR, type A dissection re-ocurred in one patient. The family member gave up the treatment, and the patient died of the dissection ruptured after cesarean section. During the average follow-up of 47.6±36.7 months, 1 patient died of cerebrovascular accident and 9 patients were reoperated for adverse cardiovascular events, including 4 in TEVAR and 5 in TAAAR.ConclusionTAAAR is the first choice for the treatment of Marfan syndrome combined with thoracoabdominal aortic diseases. TEVAR is easy to operate, with a low incidence of early mortality and complications, but has the risk of internal leakage and avulsion, and a high reoperation rate in the middle stage, so it can be used for high-risk elderly patients not suitable for open surgery, or as a bridge therapy for emergency patients before open surgery.

    Release date:2020-07-30 02:16 Export PDF Favorites Scan
  • Short-term outcome of ascending aorta replacement combined with total aortic arch fenestration technique for acute type A aortic dissection

    ObjectiveTo report our clinical experience and outcomes of thoracic endovascular aortic repair (TEVAR) for acute Stanford type A dissection using ascending aorta replacement combined with implantation of a fenestrated stent-graft of the entire aortic arch through a minimally invasive technique. MethodsFrom 2016 to 2020 in our hospital, 24 patients (17 males and 7 females, aged 45-72 years) with complicated Stanford type A aortic dissection, underwent replacement of the proximal ascending aorta with TEVAR. None of the patients with dissection involved the three branches of the superior arch, and all patients were replaced with artificial blood vessels of the ascending aorta under non-hypothermic cardiopulmonary bypass, preserving the arch and the three branches above the arch, and individualized stent graft fenestration. ResultsSurgical technical success rate was 100.0%. There was no intraoperative complication or evidence of endo-leak in 1 month postoperatively. Hospital stay was 10±5 d. During postoperative follow-up, the stent was unobstructed without displacement, the preserved branch of the aortic arch was unobstructed, and the true lumen of the descending aorta was enlarged. Conclusion This hybrid technique by using TEVAR with fenestrated treatment is a minimally invasive and effective method to treat high-risk patients with acute Stanford type A aortic dissection.

    Release date: Export PDF Favorites Scan
  • Analysis of 5-year follow-up results of hybrid surgery for complex type B aortic dissection

    Objective To analyze the clinical effect of hybrid surgery on complex type B aortic dissection in 5 years. Methods A retrospective analysis of 47 patients with complex type B aortic dissection in the Central Hospital of Wuhan affiliated to Tongji Medical College of Huazhong University of Science and Technology from 2014 to 2017 was conducted, including 42 males and 5 females with an average age of 54.9±11.2 years. Twenty-one patients underwent the left common carotid artery to the left subclavian artery bypass (a bypass group), and 26 patients underwent the left common carotid artery to the left subclavian artery transposition (a transposition group). Results All patients accepted hybrid surgery successfully. There was no statistical difference in arterial occlusion time or intraoperative blood loss between the two groups (P>0.05). The 5-year follow-up rate was 100.0% (47/47). During the follow-up period, 12 (25.5%) patients developed complications, including 5 (10.6%) patients of endoleak, 5 (10.6%) patients of hoarseness, 2 (4.3%) patients of stroke/dizziness. There was no patient of left upper limb weakness, paraplegia or retrograde aotic dissection. The reconstructed left subclavian artery remained patent in 46 (97.9%) patients. The overall 5-year survival rate was 100.0%. Conclusion The long-term therapeutic outcome of hybrid surgery for the treatment of complex type B aortic dissection is satisfying. In 5 years, the rebuilt left subclavian artery has a remarkable patency rate. Endoleak and hoarseness are the most common surgical complications.

    Release date: Export PDF Favorites Scan
  • Clinical efficacy of single branch stent-graft treatment for retrograde type A intramural hematoma

    ObjectiveTo explore the efficacy of using a single branch stent-graft to treat primary intramural hematoma located at the distal arch or descending aorta in Stanford A type aortic intramural hematoma. MethodsFrom July 2020 to November 2022, 10 patients with primary intramural hematoma of Stanford A type aortic intramural hematoma were treated with endovascular repair using a single branch stent-graft in the Department of Cardiovascular Surgery at The University of Hong Kong-Shenzhen Hospital. There were 9 males and 1 female, aged from 32 to 66 years, with a mean age of (47±10.4) years. All patients had intramural hematoma involving the ascending aorta and aortic arch, diagnosed as type A intramural hematoma, with the tear located in the descending aorta. Among them, 6 patients were complicated by ulceration of the descending aorta with intramural hematoma, and 4 patients had changes of the descending aortic dissection. All patients underwent endovascular stent repair, with 8 patients undergoing emergency surgery (≤14 days) and 2 patients undergoing subacute surgery (15 days to 3 months). Results There were no neurological complications, paraplegia, stent fracture or displacement, or limb or visceral ischemia during the perioperative period in all patients. One patient had continuous chest pain after surgery, and the stent had a new tear at the proximal end, requiring ascending aorta and partial arch replacement. As of the latest follow-up, all patients had obvious absorption or complete absorption of the intramural hematoma in the ascending aorta and aortic arch compared with before the operation. ConclusionSingle branch stent-graft treatment of retrograde ascending aortic intramural hematoma is safe and effective, with good short-term results.

    Release date: Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content