Objective To investigate the expression of transcription factors including nuclear factor-κB (NF-κB) and activator protein-1 (AP-1) in vascular endothelial cells (ECs) in different flow fields, and provide experimental evidence for mechanical signal effects on gene regulation pattern of ECs. Methods Cultured human umbilical vein ECs were loaded into steady flow chambers of laminar flow or turbulent flow and observed at 6 time points (0.5 h, 1 h, 2 h, 3 h, 4 h and 5 h) based on different load time. Spacial and temporal characteristics of NF-κB and AP-1 expression in ECs in different flow chambers were detected at a protein level by laser confocal microscope. Results In laminar flow, NF-κB expression rose to peak at 1 hour (26.49±1.63, P<0.05)and then declined. In turbulent flow, NF-κB expression rose to peak at 3 hours (34.41±6.43, P<0.05). In laminar flow, c-Jun/AP-1 expression was transiently elevated, reached its peak at 0.5 hour (18.95±5.38,P<0.05)and then fell to its baseline level. In turbulent flow, c-Jun/AP-1 expression rose slowly but steady to peak(P<0.05) . Conclusion The effects of turbulent flow on NF-κB and AP-1 expression in ECs are different from those of laminar flow. Up-regulation and activation of NF-κB and AP-1 expression in ECs induced by turbulent flow may cause pathological changes in morphological structure and functional behavior of ECs.
Abstract: Objective To summarize the experience of surgical treatment of tetralogy of Fallot (TOF) with anomalous coronary artery. Methods From March 1993 to April 2006, 22 patients with TOF and anomalous coronary artery underwent repair. The resection of hypertrophied parietal, septal band and the ventricular septal defect (VSD) repairs were performed by trans-right ventricular outflow tract (RVOT) approach in 5 cases, and by transatrial approach in 17 cases, which consisted of 7 cases required a transannular patch to enlarge a pulmonary annulus, construction of a double barrel outlet in 6 cases, by autologous pericardium conduit (3 cases), homograft (1 case) and reflected anterior wall of the main pulmonary artery in combination with bovine pericardium (2 cases). Results There was one operative death because of the anomalous coronary artery impairment. The accessory left anterior descending artery was severed because it was mistaken for the conal arteryin 1 case, which caused failure to wean from bypass, after the left internal mammary artery was anastomosed to the accessory left anterior descending artery, the cardiopulmonary bypass (CPB) was stopped successfully. Mean early gradient(ΔP) was 23.4mmHg and ΔP>20mmHg in 9 cases. Eighteen cases were followed up, mean time was 13.2 months. Late ΔP>20mmHg in 7 cases, and ΔP were less than 20mmHg in 11 cases. Conclusion The repair of TOF with anomalous coronary artery is more safe by using the transatrial approach. The surgical reconstruction of RVOT depends on the anatomic characteristic of anomalous coronary artery.
Objective To sum up the therapeutic results of corrective surgery of 164 cases of tetralogy of Fallot (TOF), and explore the optimal time and risk factors of operation,as well as perioperative management. Methods One hundred and sixty-four consecutive cases of TOF underwent corrective surgery. There were simple stenosis of infundibular portion in right ventricular outflow tract in 37 cases, stenosis of infundibulum and pulmonary valve in 14 cases, main pulmonary trunk and left/right pulmonary arteries stenosis in 113 cases, and pulmonary atresia in 5 cases. Autologous pericardial conduit, valved homograft were used for right ventriculo-pulmonary artery connection, respectively. Other anomalies were corrected. Results The surgical mortality was 3.66% (6/164). The cause of death were serious low cardiac output syndrome(2 case), fail to wean from cardiopulmonary bypass after coronary artery bypass grafting (1 case), ventricular arrhythmia(1 case) and postoperative acute respiratory distress syndrome (2 cases). Conclusion It’s necessary to perform corrective operation on younger TOF patients. Low cardiac output syndrome is not the key reason of leading to postoperative complications or death. Preventing remnant obstruction of pulmonary artery and pulmonary complication should be focused during and after operation.
ObjectiveTo investigate the reliability and safety of the technique of percutaneous left ventricular transapical access guided by cardiac three dimensional CT angiography (3D-CTA) combined with echocardiography applied in structural heart defects.MethodsThe clinical data of 9 patients (7 males and 2 females with a median age of 50 years ranging from 43 to 64 years) with paravalvular leaks closed by percutaneous left ventricular transapical access in West China Hospital, from April 2015 to August 2018, were retrospectively analyzed. We applied preoperative cardiac 3D-CTA to define the puncture site and trace, which was established by combining with real-time guidance of transesophageal echocardiography (TEE/3D-TEE), and an occluder was deployed at the apical access point for hemostasis with real-time guidance of transthoracic echocardiography (TTE).ResultsThe puncture needles were successfully introduced into the left ventricular cavity at one time in all patients without injury of lung tissue, coronary artery or papillary muscle. There was no occluder displacement or apex bleeding. One patient developed pleural effusion caused by intercostal artery injury.ConclusionThat cardiac 3D-CTA is used to define puncture sites and trace with advantages of simplicity and repeatability. A safe access and secure exit of left ventricle can be achieved by combining with real-time guidance of echocardiography. There are acceptable technology-related complications.