west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "闭合器" 6 results
  • Application of Domestic Stapler and Suture Device in Digestive Tract Reconstruction of Esophageal Cancer

    目的 评价国产吻合器和闭合器在食管癌消化道重建术中的应用价值。 方法 回顾性分析2005年3月-2008年4月期间收治的387例食管癌手术患者的临床资料,根据不同消化道重建方式分为手工吻合组(n=172)和器械吻合组(n=215),对两组患者吻合时间、术中出血量及术后并发症发生情况进行对比分析。 结果 全组无手术死亡。器械吻合组和手工吻合组术中出血量的差别无统计学意义(Pgt;0.05),但前者的吻合时间、住院时间均少于后者(Plt;0.05)。手工吻合组术后吻合口出血多于器械吻合组(5.2%比1.4%,Plt;0.05),发生吻合口漏亦多于器械吻合组(6.4%比2.8%,Plt;0.05)。随访1.5~2年,排除失访患者后,器械吻合组吻合口狭窄发生率低于手工吻合组(4.6%比10.3%,Plt;0.05)。 结论 国产吻合器与和缝合器用于食管癌的消化道重建安全有效,值得在基层医院推广应用。

    Release date:2016-09-08 09:49 Export PDF Favorites Scan
  • Design and Fabrication of a Device for Intraperitoneal Treatment of Pediatric Hernia

    For treatment of pediatric inguinal hernia, we fabricated a device, i.e. so called "filling type pediatric hernia sac", which treats the problem from the abdominal cavity, through the abdominal and is a self-adaptive closer, using synthetic material. The device includes filling rack, self-adaptive umbrella support bar, bottom piece, outside pulling line and device fixing lines. The filling rack is composed of 2 concentric circles of 3.0 cm diameter with peripherally fixed together and can be pulled into the shapes of a ball or an olive. The supporting bar is structured of 3 pieces with 0.5 cm wide, 4.0 cm long, cross-fixed on top of the filling rack. The bottom piece is in a circular structure with a diameter of 3.0 cm, and it is connected to the filling rack bottom. Adjust positioning stay outside the fixed on the top of the device are connected at one end, and the other end free through filling the top frame connected with the bottom slice of central fixation. By using this device, we treated 37 pediatric inguinal hernia cases with 38 side-inguinal hernia successfully. The mean duration of post-operation follow-ups was 14.6±5.89 months, without hernia recurrence, obvious scar and hard sections of inguinal region. This device could provide a convenient, safe and effective plugging technology for children's pediatric hernia.

    Release date: Export PDF Favorites Scan
  • Clinical Analysis of Application of The Cutting Closure Device in Laparoscopic Cholec-ystolithotomy

    ObjectiveTo evaluate the value of incision closure device in laparoscopic cholecystolithotomy. MethodsThe clinical data of 130 patients underwent laparoscopic cholecystectomy from Oct. 2014 to Feb. 2015 were retrospectively analyzed. According to the methods of gallbladder suture, 130 cases were divided into two groups, 72 cases underwent traditional manual suture (MS group), and 58 cases underwent incision closure device (ICD group). The operative time, postoperative gastrointestinal function recovery time, bleeding volume, postoperative hospitalization time, hospitalization expenses, complications, and postoperative 6-12 months follow-up of patients in 2 groups were observed.Results One hundred and thirty cases were performed laparoscopic cholecystolithotomy successfully. The operative time and postoperative gastrointestinal function recovery time of ICD group were significantly shorter than those of MS group, the difference was statistically significant (P < 0.05). The hospitalization expenses of the patients in ICD group were significantly higher than those in the MD group (P < 0.05). There were no significant difference between the two groups in the bleeding volume and postoperative hospital stay (P > 0.05). The patients were followed up for 6-12 months, with an average of 8 months, and no complications occurred and stone recurrence. ConclusionIncision closure device can shorten the time of laparoscopic cholecystolithotomy and postoperative recovery of gastrointestinal function, but the cost is higher. Next development, still need decrease the expend and strengthen clinical promotion.

    Release date: Export PDF Favorites Scan
  • Application of modified adjustable skin stretching and secure wound-closure system in repairing of skin and soft tissue defect

    Objective To investigate the application of modified adjustable skin stretching and secure wound-closure system in repairing of skin and soft tissue defect. Methods Between March 2016 and April 2017, 21 cases of skin and soft tissue defects were repaired with the modified adjustable skin stretching and secure wound-closure system (the size of regulating pressure and the times of adjustment were determined according to the color, temperature, capillary response, and swelling degree of the skin edge). There were 11 males and 10 females, with an average age of 49.2 years (range, 21-67 years). Among them, 1 case was the residual wound after amputation of leg; 18 cases were the wounds after traumatic injury operation, including 4 cases in the lower leg, 3 cases in the knee joint, 7 cases in the upper limb, and 4 cases in the foot; and 2 cases were diabetic feet. The skin defect area ranged from 4.0 cm×2.5 cm to 21.0 cm×10.0 cm. Results Skin defect wounds closed directly in one stage in 4 cases; 12 cases were closed after continuously stretching for 5-14 days (mean, 10 days); 5 cases were reduced to less than one-half area, and the wound healed after the second skin grafting or flap repairing. All the 21 patients were followed up 3-12 months (mean, 5.2 months). The wound was linear healing with small scar, and no invasive margin, poor blood flow, necrosis, and poor sensory function happened. Conclusion The modified adjustable skin stretching and secure wound-closure system can reduce the skin and soft tissue defects or close the wound directly, and even replace the skin graft and skin flap repairing. It was a good method for the treatment of skin and soft tissue defect.

    Release date:2017-12-11 12:15 Export PDF Favorites Scan
  • Application of skin stretching device in repair of diabetic foot wound

    ObjectiveTo evaluate the clinical value of skin stretching device in repair of diabetic foot wound.MethodsA retrospective analysis was made on the clinical data of 48 cases with diabetic foot wound who were treated with skin stretching device (trial group, n=24) and with the vacuum sealing drainage combined with skin graft (control group, n=24) respectively between October 2015 and July 2016. There was no significant difference in gender, age, side, course of disease, TEXAS stage between 2 groups (P>0.05). Both patients in 2 groups were treated with sensitive antibiotics according to the results of bacterial culture.ResultsOne case in control group was infected and the skin graft failed, and 1 case in trial group was infected after the treatment, and the two wounds healed after symptomatic treatment. The wounds of the other patients healed successfully, and the healing time of the trial group was significantly shorter than that of the control group [(12.8±11.6) days vs. (22.3±10.4) days; t=2.987, P=0.005). All patients were followed up 3-12 months after operation, and no wound dehiscence or recurrence occurred during follow-up.ConclusionCompared with the vacuum sealing drainage combined with skin graft, the application of skin stretching device in the repair of diabetic foot wound has advantages, such as easy to operate, shorten the wound healing time, and the appearance of wound was similar with the adjacent skin.

    Release date:2018-05-02 02:41 Export PDF Favorites Scan
  • The application and progress of vascular closure devices

    Peripheral vascular path is an important approach for minimally invasive cardiovascular surgery and cardiovascular interventional diagnosis and treatment, and the treatment of the vascular approach after surgery is directly related to the postoperative braking time and comfort of patients. The traditional treatment methods mainly include compression fixation of puncture point or incision of skin to suture blood vessels, but the disadvantages such as long postoperative immobilization, potential vascular complications and patient discomfort are obvious. The application of vascular closure devices can reduce the shortcomings of traditional treatment methods, but different vascular closure devices have their characteristics and application scope, and improper application may lead to serious complications. This paper reviewed the information of several commonly used vascular closure device and relevant clinical research data in recent years, and introduced the characteristics, application and clinical effects of common vascular closure devices.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content