west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "陈东阳" 8 results
  • 膝关节镜下前交叉韧带重建术后药物热一例

    Release date:2017-03-13 01:37 Export PDF Favorites Scan
  • 机器人辅助下“比基尼”切口直接前入路人工全髋关节置换术治疗强直性脊柱炎骨性融合髋一例

    Release date: Export PDF Favorites Scan
  • Effectiveness of a single threaded anchor fixation under shoulder arthroscopy in treatment of fresh bony Bankart injury

    Objective To investigate the effectiveness of a single threaded anchor fixation under shoulder arthroscopy in the treatment of fresh bony Bankart injury. Methods Between January 2017 and May 2021, 12 patients with fresh bony Bankart injury caused by trauma were treated with a single threaded anchor fixation under shoulder arthroscopy. There were 10 males and 2 females with an average age of 38.8 years (range, 21-64 years). The time between injury and operation ranged from 7 to 30 days (mean, 15.8 days). Preoperative American Shoulder and Elbow Surgeons (ASES) score was 44.9±17.4, the University of California at Los Angeles (UCLA) score was 13.1±5.5; the forward supination, lateral external rotation, and lateral internal rotation of shoulder were (130.8±11.8)°, (25.0±7.9)°, and 9.2±1.6, respectively. CT scan and three-dimensional (3D) reconstruction showed that the fracture fragment area was less than 1/4 of the glenoid area in 10 cases, and 1/4-1/2 in 2 cases. The operation time was recorded. During follow-up, ASES score, UCLA score, Rowes score, and shoulder range of motion were used to evaluate the effectiveness, and shoulder CT scan and 3D reconstruction were used to evaluate the fracture position and healing. Results The operation time ranged from 50 to 150 minutes (mean, 85.5 minutes). All patients were followed up 3-18 months (mean, 9.1 months). There was no serious adverse effect such as infection, re-dislocation, or thrombosis. Three patients had shoulder adhesions after operation. At last follow-up, the forward supination of shoulder [(162.1±30.3)°], lateral external rotation [(37.5±11.2)°], and lateral internal rotation (9.2±1.6) significantly improved when compared with those before operation (t=3.331, P=0.003; t=3.153, P=0.005; t=2.716, P=0.013). The ASES score was 89.7±11.8 and the UCLA score was 32.8±2.4, which significantly increased when compared with those before operation (t=7.368, P<0.001; t=11.370, P<0.001). The Rowes score ranged from 75 to 100 (mean, 92.9). Among them, 9 cases were excellent and 3 cases were good, with an excellent and good rate of 100%. CT re-examination showed that the fracture line disappeared in 11 cases, and the fracture alignment was good; the alignment of the fracture fragment was poor in 1 case whose fracture fragment area was between 1/4 and 1/2 of the glenoid area. Conclusion For the fracture fragment area not exceeding 1/4 of the glenoid, the labrum-capsule complex at the lower end of the bone fragment intact, and the non-comminuted fresh bony Bankart injury, a single threaded anchor fixation under shoulder arthroscopy can achieve better effectiveness, has the advantages of less trauma and faster postoperative recovery.

    Release date: Export PDF Favorites Scan
  • Effectiveness analysis of MAKO robotic-arm assisted total hip arthroplasty via direct anterior approach for bony fused hips

    Objective To investigate the effectiveness of MAKO robotic-arm assisted total hip arthroplasty (THA) via direct anterior approach (DAA) for bony fused hips in ankylosing spondylitis (AS). Methods Between June 2021 and January 2022, MAKO robotic-arm assisted THA via DAA was applied to treat 10 cases (12 hips) of AS with bony fused hips. There were 7 males and 3 females; the age ranged from 30 to 71 years, with an average age of 42.4 years. The duration of AS was 12-35 years, with an average of 21.4 years. The preoperative hip was ankylosed in flexion in 3 cases, with a flexion angle of 20°, 30°, 35°, respectively; 9 cases were ankylosed in extension. The operation time and complications were recorded; the visual analogue scale (VAS) score, Harris score, and Oxford hip scale (OHS) score before and after operation, and postoperative range of motion (flexion, extension, internal rotation, external rotation, adduction, and abduction) were used to evaluate the recovery of joint function; according to the postoperative anteroposterior X-ray film and CT scan of both hip joints, the abduction angle, anteversion angle, the difference between bilateral combined off-set and the lower limb length discrepancy were measured. Results The operation time ranged from 80 to 190 minutes (mean, 134.6 minutes). All 10 patients were followed up 5-11 months (mean, 7.4 months). There was no serious adverse events such as incision infection, deep vein thrombosis of lower extremities, hip redislocation, aseptic loosening of the prosthesis, or death. At 5 months after operation, the acetabular prosthesis angle of abduction was 37°-45° (mean, 40.3°), anteversion angle was 9°-20° (mean, 15.8°). The difference between bilateral combined off-set was 0-10 mm (mean, 4.3 mm); the lower limb length discrepancy was 0-12 mm (mean, 3.5 mm). At last follow-up, the average range of motion of the hip joint was 89.2° in flexion (range, 80°-100°), 1.7° in extension (range, –5°-10°), 7.1° in internal rotation (range, 0°-15°), 20.4° in external rotation (range, 10°-30°), 7.9° in adduction (range, 0°-20°), and 16.5° in abduction (range, 10°-25°). At last follow-up, the VAS score, Harris score, and OHS score significantly improved when compared with those before operation (P<0.05). ConclusionThe MAKO robotic-arm assisted THA via DAA can achieve satisfactory results in the treatment of AS with bony fused hip, which has the advantages of accurate prosthesis installation, soft tissue release, and less trauma during operation.

    Release date: Export PDF Favorites Scan
  • Correlation study on the influencing factors of semitendinosus insertion location

    Objective To investigate the relationship between the vertical distance from semitendinosus insertion to tibial plateau (S-T) and the physical characteristics of patients, in order to provide reference for incision design to expose the semitendinosus insertion. Methods The patients with ligament injury who underwent primary anterior cruciate ligament reconstruction between January 2022 and December 2022 were selected as the research subjects. The patients’ baseline data were collected, including age, gender, height, and body mass. During reconstruction operation, the S-T was measured. Considering the S-T as the dependent variable and baseline data as the independent variable, multiple linear regression analysis was used to establish a regression equation to determine the possible influencing factors of semitendinosus insertion location. Results According to the selection standard, a total of 214 patients were enrolled, including 156 males and 58 females, aged (27±9) years (14-49 years), with a height of (174.7±6.8) cm (range, 160-196 cm) and a body mass of (73.43±12.35) kg (range, 53-105 kg). The S-T was (56.36±3.61) mm (range, 47-67 mm). The multiple linear regression analysis results showed that the height was positively correlated with S-T (β=0.407, SE=0.055, t=7.543, P<0.001); the regression equation was S-T=−14.701+0.407×height, R2=0.690. ConclusionThere was a linear relationship between the height and semitendinosus insertion. The location of semitendinosus insertion estimated by the formula (S-T=−14.701+0.407×height) is reasonable, which provides a theoretical basis for rapid, accurate, and safe location of semitendinosus insertion and design of surgical incision in clinic.

    Release date: Export PDF Favorites Scan
  • COMPARISON OF TOTAL KNEE ARTHROPLASTY WITH COMPUTER NAVIGATION SYSTEMS AND CONVENTIONAL TECHNIQUES

    ObjectiveTo evaluate the value of total knee arthroplasty (TKA) with computer navigation by comparing with conventional TKA. MethodsBetween May 2010 and December 2011, 45 patients underwent primary unilateral TKA, and the clinical data were retrospectively analyzed. Of 45 patients, 22 cases were treated with TKA with computer navigation (group A), 23 cases with the conventional TKA (group B). There was no significant difference in gender, age, body mass index, side, cause of disease, disease duration, preoperative range of motion (ROM) of the knee, and preoperative Hospital for Special Surgery (HSS) score between 2 groups (P > 0.05). The operation time, intraoperative blood loss, incidence of patellar retinacular release, complication, and drainage volume were compared. The prosthesis loosening, postoperative HSS score, and ROM of the knee were also compared. ResultsNo difference was found in the incidence of patellar retinacular release during TKA, and it was 13.6% (3/22) in group A and was 4.3% (1/23) in group B, showing no significant difference (χ2=1.198, P=0.346). The operation time of group A was significantly longer than that of group B (t=7.557, P=0.000). There was no significant difference in intraoperative blood loss during TKA between 2 groups (t=-0.295, P=0.769), while the drainage volume of group A was significantly less than that of group B (t=-2.419, P=0.020). Incomplete fracture during TKA and acute infection occurred at 8 days after TKA in 1 case of group A respectively, while no fracture or infection was found in group B, showing significant difference (Z=-0.509, P=0.000). The patients of 2 groups were followed up 27-46 months. No significant difference in valgus and varus of knee, and malalignment of the femoral and tibial prosthesis was found (P > 0.05). There was no significant difference in HSS score and ROM of the knee at last follow-up between 2 groups (P > 0.05). No prosthesis loosening was found in 2 groups. ConclusionTKA with computer navigation has similar results to conventional TKA in the mechanical alignment, but it obviously prolongs operation time. It may also increase the incidence of infection and tractor pin related fracture.

    Release date: Export PDF Favorites Scan
  • Transverse small incision intrathecal “loop” minimally invasive suture for treatment of acute Achilles tendon rupture

    Objective To evaluate the effectiveness and feasibility of a transverse small incision intrathecal “loop” minimally invasive suture for acute Achilles tendon rupture. Methods The clinical data of 30 patients with acute Achilles tendon rupture treated with transverse small incision intrathecal “loop” minimally invasive suture between January 2022 and October 2023 was retrospectively analyzed. The patients were all male, aged from 29 to 51 years, with an average of 39.8 years. The cause of injury was acute sports injury, and the time from injury to operation was 1-14 days, with an average of 3.4 days. The operation time, incision length, intraoperative blood loss, intraoperative complications, wound healing, and hospital stay were recorded. Postoperative appearance and function of ankle were evaluated by American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score, Vancouver Scar Scale (VSS) score, and Arner-Lindholm score. Results The operation time ranged from 30 to 90 minutes, with an average of 54.2 minutes; the incision length ranged from 1.3 to 3.5 cm, with an average of 2.2 cm; the intraoperative blood loss ranged from 5 to 70 mL, with an average of 22.3 mL; and the hospital stay ranged from 2 to 6 days, with an average of 3.7 days. All incisions healed by first intention, and there was no incision infection, poor healing, and deep venous thrombosis. All patients were followed up 5.3-22.0 months (mean, 14.7 months). During the follow-up, all the 30 patients had returned to exercise, and there was no complication such as Achilles tendon re-rupture, postoperative infection, and gastrocnemius muscle injury. At last follow-up, the AOFAS ankle-hindfoot score was 82-100, with an average of 95.1; the VSS score was 1-4, with an average of 2.1; according to the Arner-Lindholm score, 24 cases were rated as excellent and 6 cases as good. Conclusion Transverse small incision intrathecal “loop” minimally invasive suture for the treatment of acute Achilles tendon rupture has the advantages of simple instrument, convenient operation, small trauma, quick recovery, and satisfactory effectiveness.

    Release date: Export PDF Favorites Scan
  • Effectiveness analysis of “tail compression fixation+suture bridge” technology under shoulder arthroscopy for treating primary tear in medial enthesis of rotator cuff

    ObjectiveTo investigate the feasibility and effectiveness of “tail compression fixation+suture bridge” technology under shoulder arthroscopy for treating primary tear in medial enthesis of rotator cuff. Methods The clinical data of 11 patients with primary tear in medial enthesis of rotator cuff who met the selection criteria between October 2020 and October 2022 were retrospectively analyzed, including 3 males and 8 females, aged 39-79 years, with an average of 61.0 years. Rotator cuff injury was caused by traumatic fall in 8 cases, and the time from injury to admission was 1-4 months, with an average of 2.0 months; the remaining 3 cases had no obvious inducement. The active range of motion of the affected shoulder was limited, with an active forward flexion range of motion of (64.1±10.9)°, abduction of (78.1±6.4)°, internal rotation of (48.2±6.6)°, and external rotation of (41.8±10.5)°; 5 cases had shoulder stiffness. The preoperative visual analogue scale (VAS) score was 7.8±0.8 and the American Society of Shoulder and Elbow Surgeons (ASES) score was 23.9±6.4. The patients were treated with “tail compression fixation+suture bridge” technology under shoulder arthroscopy, and the pain and functional recovery were evaluated by VAS score, ASES score, and active range of motion of shoulder joint at last follow-up; MRI was performed after operation, and the integrity of rotator cuff was evaluated by Sugaya classification system. Results All the 11 patients were followed up 2-22 months, with an average of 13.5 months. All incisions healed by first intention, and there was no complication such as infection, rotator cuff re-tear, and anchor falling off. At last follow-up, the VAS score was 0.8±0.7 and the ASES score was 93.5±4.2, which significantly improved when compared with those before operation (P<0.05). All 11 patients had no significant swelling in the shoulders, and the active range of motion was (165.1±8.8)° in flexion, (75.3±8.4)° in abduction, (56.6±5.5)° in internal rotation, and (51.8±4.0)° in external rotation, which significantly improved when compared with those before operation (P<0.05). Shoulder MRI showed adequate tendon thickness and good continuity in 9 cases, including 4 cases with partial high signal area; and 2 cases with inadequate tendon thickness but high continuity and partial high signal area. According to Sugaya classification system, there were 4 cases of type 1 (36.4%), 5 cases of type 2 (45.5%), and 2 cases of type 3 (18.1%).Conclusion For the patients with primary tear in medial enthesis of rotator cuff, the “tail compression fixation+suture bridge” technology under shoulder arthroscopy is simple and effective.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content