目的 探讨神经外科危重患者经外周静脉置入中心静脉导管(PICC)的常见并发症发生原因,同时总结并发症有效预防措施及护理对策。 方法 纳入2009年9月-2012年9月期间行PICC的190例神经外科重症住院患者,统计并发症发生率,对其原因进行分析,并开展针对性预防和护理。 结果 本组患者PICC置管后有75例发生不同类型并发症,其中置管时并发症17例,包括导管异位8例,送管困难6例,穿刺失败3例,发生率为9%;导管留置期间并发症58例,包括穿刺点渗血、渗液16例,意外拔管12例,静脉炎10例,导管部分脱出9例,导管堵塞7例,导管相关性感染3例,导管相关性静脉血栓1例,发生率为30.5%。根据其发生的不同原因,采取积极的治疗和护理措施,并发症得以治愈,降低了并发症发生率。 结论 规范护理流程,加强临床培训,熟悉和掌握PICC并发症的预防和护理措施,可提高PICC置管、使用的安全性。
Objective To explore the risk factors of catheter-associated bloodstream infections ( CRBSI) in intensive care unit ( ICU) of primary hospital. Methods A total of 623 patients with central venous catheters were recruited in the study. 60 of themsuffered fromCRBSI served as an observation group and other 563 cases without CRBSI served as control. Univariate analysis was used to scan possible risk factors. Then logistic regression analysis was used to exclude the confounding factors. Results The overall incidence rate of CRBSI was 9. 63% ( 60 /623) . There were significant differences in APACHE score, type of catheter, location of catheter, duration of central venous catheter, intravenous nutrition, use of steroid, times of intubation, urgent intubations, nutritional status, diabetes, and MODS between the two groups. Logistic regression analysis revealed that higher APACHE score, double-lumen catheter, femoral vein catheter, catheter indwelling more than two weeks, intravenous nutrition, intubation more than 2 times, and emergency intubation were risk factors of CRBSI. Conclusions Higher APACHE score, double-lumen catheter, femoral vein catheter, catheter indwelling more than two weeks, intravenous nutrition, intubation more than 2 times, and emergency intubation were major risk factors of CRBSI in ICU of primary hospital.
ObjectiveTo explore the influence of three central venous catheter biomedical materials (polyurethane, silicone, and polyvinyl chloride) on the proliferation, apoptosis, and cell cycle of Xuanwei Lung Cancer-05 (XWLC-05) cells so as to provide the basis for clinical choice of central venous catheter. MethodsXWLC-05 cells were cultured and subcultured, and the cells at passage 3 were cultured with polyurethane, silicone, and polyvinyl chloride (1.0 cm × 1.0 cm in size), and only cells served as a control. At 24, 48, and 72 hours after cultured, MTT assay was used to detect the cellular proliferation and flow cytometry to detect the cell cycle and apoptosis. At 72 hours after cultured, inverted microscope was used to observe the cell growth. ResultsInverted microscope showed the cells grew well in control group, polyurethane group, and silicone group. In polyvinyl chloride group, the cells decreased, necrosed, and dissolved; residual adherent cells had morphologic deformity and decreased transmittance. At 24 and 48 hours, no significant difference in proliferation, apoptosis, and cell cycle was found among 4 groups (P gt; 0.05). At 72 hours, the proliferations of XWLC-05 cells in three material groups were significantly inhibited when compared with control group (P lt; 0.05), and the cells in polyvinyl chloride group had more significant proliferation inhibition than polyurethane group and silicone group (P lt; 0.05), but there was no signifcant difference in proliferation inhibition between polyurethane group and silicone group (P gt; 0.05). Compared with the control group, three material groups had significant impact on the rate of apoptosis and cell cycle: polyvinyl chloride group was the most remarkable, followed by silicone group, polyurethane group was minimum (P lt; 0.05). ConclusionPolyvinyl chloride can significantly impact the proliferation, apoptosis, and cell cycle of XWLC-05 cells; polyurethane has better biocompatibility than polyvinyl chloride and silicone
Objective To make an individualized administration scheme via evidence-based medicine methods, namely adding heparin into the total nutrient admixture (TNA) solution, so as to help a neonate to prevent the occlusion of peripherally inserted central catheter (PICC). Methods After carefully assessing the condition of neonate, this clinical issue was put forward in accordance with the PICO principles. Randomized controlled trials (RCTs) and systematic reviews on neonates’ PICC occlusion were collected from The Cochrane Library, CCTR, DARE, NGC, MEDLINE (Ovid) and CBM from inception to 2011. The clinical intervention scheme was finally made after the assessment of the retrieved evidence and neonate’s physiological condition. Results A total of 4 RCTs and 1 systematic review related to the issues were identified. The following scheme was finally made for the neonate through the assessment of the retrieved evidence and combination of intentions of the patient’s family members: heparin (0.5 U/mL) was added into TNA to prevent PICC occlusion. During the application, blood routine test and blood coagulation were monitored, and the catheter opening time and extubation reason were recorded. Through the above treatment, the neonate successfully completed the treatment before extubation. The time of both PICC detaining and opening was 20 days in total, and there were no PICC occlusion, no catheter thrombosis, and no catheter related bloodstream infection. Moreover, no observation showed thrombopenia and aggravated coagulation disorders resulted from heparin. Conclusion The evidence-based medicine method is an effective way to make reasonable heparin scheme for neonate, so as to prevent PICC occlusion, reduce catheter thrombosis, decrease risks of catheter related blood circulation infection, assure successful completion of treatment, and guarantee the safety of patients.
目的 分析不同孕周正常胎儿静脉导管的频谱特征及血流频谱参数,得到不同孕周胎儿各频谱参数的正常参考值范围。 方法 2011年6月-9月检测记录不同孕周胎儿的静脉导管波形及各频谱参数,统计各频谱参数的正常参考值范围,并评估与其孕周的相关性。 结果 胎儿静脉导管的频谱速度参数与孕周呈正相关,阻力参数与孕周呈负相关,均以11~20周变化趋势较明显,其中3.59%的胎儿静脉导管频谱出现异常。 结论 正常胎儿的静脉导管血流参数与孕周有较好的相关性,静脉导管频谱在孕16周前可出现生理性的异常。