west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "黎乐群" 5 results
  • 肝癌合并门静脉癌栓外科治疗进展:超巴塞罗那肝癌诊疗指南

    Release date:2019-05-08 05:37 Export PDF Favorites Scan
  • 肝癌合并门静脉癌栓的外放射治疗研究现状

    Release date:2019-05-08 05:37 Export PDF Favorites Scan
  • Identification of Cell Clonal Origin of Multinodular Hepatocellular Carcinoma by Analyzing Mitochondrial DNA D-Loop Region Variations

    Objective To explore the feasibility of identifying clonal origin of hepatocellular carcinoma (HCC) by analyzing the mitochondrial DNA D-Loop region variations. Methods Forty-two patients with a total of 112 HCC nodules consequentially hospitalized for radical resection of HCC in the department of hepatobiliary surgery of the First Affiliated Hospital of Guangxi Medical University from April 2004 to August 2007 were included for study group (multinodular HCCs). Control group included 20 cases of HCC (40 samples) hospitalized in the same period that consisted of two sub-groups: control groupⅠconsisted of 16 cases of single nodular HCC that each had two pieces of inconsecutive tumor tissues and control groupⅡconsisted of 4 cases of HCC with portal vein tumor embolus whose tumor tissues and portal vein tumor embolus were collected simultaneously. Normal control included 5 patients who were donors for liver transplantation or underwent liver trauma without any liver disease. Polymerase chain reaction (PCR) and direct sequencing were applied to study the mtDNA D-Loop region. The sequences of multinodular lesions were compared among different groups. Results For all the 42 cases of the study group, basic group variations appeared in 131 sites (131/1 122, 11.7%, the number 1 122 was the length of mtDNA D-Loop) with point mutation in 15 sites, insert in 9 sites, and deletion in 16 sites. And of all the variations in the study group, 98 were polymorphism. In study group, 20 cases were categorized as multicentric occurrence (MO) based on their variant mtDNA D-Loop sequences in each nodule from the same patient. And 22 cases were characterized as intrahepatic metastasis (IM) based on the identical mtDNA D-Loop sequences found in each nodule from the same patient. In all 20 cases in the control group, the inconsecutive tumor tissues or the portal vein tumor embolus and original tumors shared identical mtDNA D-Loop sequences. For the normal control group, basic group variations appeared in 14 sites, and they were all polymorphism including a new polymorphism (NT 479 Agt;G). Conclusions There is a high rate of changes in mtDNA D-Loop region. And our study speculates a novel discrimination of MO and IM origins among multinodular HCCs using PCR and direct sequencing of the mtDNA D-Loop sequences.

    Release date:2016-09-08 10:54 Export PDF Favorites Scan
  • Effectiveness and Safety of Implanting Sustained-Release 5-Fluorouracil during Hepatectomy for Primary Liver Cancer: A Systematic Review

    Objective To systematically review the effectiveness and safety of implanting sustained-release 5-fluorouracil during hepatectomy in patients with primary liver cancer (PLC). Methods We electronically searched the following databases including CENTRAL, MEDLINE, EMbase, WanFang Data, CBM, CNKI and VIP to collect randomized controlled trials (RCTs) on the effectiveness and safety of implanting sustained-release 5-fluorouracil during hepatectomy vs. hepatectomy alone for PLC from inception to October, 2012. Two reviewers independently screened literature according to the inclusion and exclusion criteria, extracted data and assessed the quality of the included studies. Then, meta-analysis was performed using RevMan 5.0 software. Results A total of 6 RCTs involving 951 patients were included. The results of meta-analysis showed that, implanting sustained-release 5-fluorouracil during hepatectomy significantly decreased the total recurrence rates of 1-year and 3-year (1 year: RR=0.48, 95%CI 0.36 to 0.65, Plt;0.000 01; 3 years: RR=0.69, 95%CI 0.50 to 0.96, P=0.03). However, the two groups were alike in decreasing the surem levels of AFP. Besides, the commonly-seen adverse reaction of implanting sustained-release 5-fluorouracil during hepatectomy included abdominal pain and bile leakage. Conclusion Implanting sustained-release 5-fluorouracil during hepatectomy can decrease the 1-year and 3-year recurrence rates of PLC patients, especially for HCC at the early stage. But this conclusion should be interpreted with caution and needs more strictly-designed RCTs with large sample size and enough long follow-up to verify.

    Release date: Export PDF Favorites Scan
  • Measurement of Urinary 8Hydroxydeoxyguanosine Level with a HighPressure Liquid Chromatography Eectrochemical Approach

    ObjectiveTo investigate the methodology of a newly developed highpressure liquid chromatography electrochemical system in urinary 8hydroxydeoxyguanosine (8OHdG) quantification. MethodsQuantification of urinary 8OHdG with ESA 5600 Coularray system among 21 children from liver cancer highrisk areas, Fusui country, in contrast with 63 controls from Nanning city, Guangxi province.ResultsThe resolution, sensitivity, linearity, precision and recovery of this approach all fully meet the requirement of routine urinary 8OHdG quantification. The mean 8OHdG level of this population was (5.26±0.41) ng/mg creatinine, higher than previous report 〔(4.62±0.091) ng/mg creatinine〕 by similar method.ConclusionWith cautious design and modification, this method is reliable and accurate in high throughput quantification of urinary 8OHdG.

    Release date:2016-08-28 04:49 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content