west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "3D heads-up display viewing system" 2 results
  • Combining 3D heads-up display viewing system and intraoperative optical coherence tomography-assisted vitrectomy for myopic foveoschisis

    ObjectiveTo observe the clinical efficacy of digital 3D heads-up display viewing system (3D viewing system) and intraoperative OCT (iOCT) in vitrectomy for myopic foveoschisis (MF).MethodsA retrospective, consecutive case series. From October 2018 to May 2019, Nineteen eyes of 19 consecutive patients with MF diagnosed in Xiamen Eye Center of Xiamen University who underwent vitrectomy were included in this study. There were 7 males and 12 females, with the mean age of 54.47±11.38 years. The average axial length was 30.40±2.30 mm, the mean logMAR BCVA was 0.56±0.31, the mean central foveal thickness (CFT) was 317.80±151.9.32 μm, the mean max retinal thickness (maxRT) was 556.7±143.7 μm. All the surgeries performed combined with 3D viewing system with iOCT. The standard 25G pars planar vitrectomy were performed with removing the posterior vitreous and indocyanine green (ICG) staining of internal limiting membrane (ILM) and air-fluid exchange. Thirteen of 19 eyes underwent fovea-sparing ILM peeling and the other 6 eyes not. The average follow-up was 4.2±1.4 months. All the patients were on regular follow-up to document the changes on BCVA, anatomical changes in macula, CFT and maxRT. Paired t test was used to compare BCVA, CFT and maxRT before and after surgery.ResultsThe fine images of macula were clearly shown on the 3D viewing system in all eyes. The electronic green filter enhanced the contrast sensitivity of ICG stained images. Clear images of macula were captured by iOCT in all eyes. The average surgical time was 35.5±8.2 min. On the last follow-up, 16 of 19 eyes with MF resolved. The mean CFT was 178.5±103.5 μm, the maxRT was 341.8±83.8.16 μm, and the mean logMAR BCVA was 0.35±0.22. The differences of CFT, maxRT and logMAR BCVA before and after surgery were statistically significant (t=4.181, 7.154, 5.129; P<0.001). Minimal invisible full thickness macular hole were detected in 2 eyes by iOCT and repaired with auto serum or ILM flap covering. There was no complication associated with the 3D viewing system.Conclusions3D viewing system provides improved contrast and crystal clear macular image stain with ICG in pathological myopia. iOCT can detect the minimal invisible full thickness macular hole during surgery. Both may contribute to improved MF closure rate and BCVA.

    Release date:2020-01-11 10:26 Export PDF Favorites Scan
  • The application and perspectives of 3D heads-up display viewing system in vitreoretinal surgery

    There has been ongoing progress in the new technique and equipment in vitreoretinal surgery in recent years, contributing to the improvement of treatment of various vitreoretinal diseases. The application of 3D heads-up display viewing system (3D viewing system) has been one of the most fascinating breakthroughs in vitreoretinal surgery. Unlike the traditional method in which the surgeons have to look through the microscope eyepieces, this system allows them to turn their heads up and operate with their eyes on a high-definition 3D monitor. It provides the surgeons with superior visualization and stereoscopic sensation. And increasing studies have revealed it to be as safe and effective as the traditional microscopic system. Furthermore, the surgeons can keep a heads-up position in a more comfortable posture and lesson the pressure on cervical spine. Meanwhile, 3D viewing system makes it easier for the teaching and learning process among surgeons and assistants. However, there are still potential disadvantages including the latency between surgeon maneuver and visualization on the display, learning curves and cost. We hope that the 3D viewing system will be widely used and become a useful new tool for various vitreoretinal diseases in the near future with rapid development in the technology and constant upgrade of the system.

    Release date:2020-01-11 10:26 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content