west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Animal robot" 3 results
  • Research and application of photovoltaic cell online monitoring system for animal robot stimulator

    Power supply plays a key role in ensuring animal robots to obtain effective stimulation. To extending the stimulating time, there is a need to apply photovoltaic cells and monitor their parameter variations, which can help operators to obtain the optimal stimulation strategy. In this paper, an online monitoring system of photovoltaic cells for animal robot stimulators was presented. It was composed of battery information sampling circuit, multi-channel neural signal generator, power module and human-computer interaction interface. When the signal generator was working, remote navigation control of animal robot could be achieved, and the battery voltage, current, temperature and electricity information was collected through the battery information sampling circuit and displayed on the human-computer interaction system in real time. If there was any abnormal status, alarm would be activated. The battery parameters were obtained by charging and discharging test. The battery life under different light intensity and the stimulation effect of neural signal generator were tested. Results showed that the sampling errors of battery voltage, current and electric quantity were less than 15 mV, 5 mA and 6 mAh, respectively. Compared with the system without photovoltaic cells, the battery life was extended by 148% at the light intensity of 78 320 lx, solving the battery life problem to some extent. When animal robot was stimulated with this system, left and right turns could be controlled to complete with the success rate more than 80%. It will help researchers to optimize animal robot control strategies through the parameters obtained in this system.

    Release date: Export PDF Favorites Scan
  • Simulation design and experimental study of magnetic stimulation coil for robot pigeon

    To explore the feasibility of applying magnetic stimulation technology to the movement control of animal robots, the influence of coil radius, number of turns and other factors on the intensity, depth and focus of magnetic stimulation was simulated and analyzed for robot pigeons. The coil design scheme was proposed. The coil was placed on the head and one of the legs of the pigeon, and the leg electromyography (EMG) was recorded when magnetic stimulation was performed. Results showed that the EMG was significantly strengthened during magnetic stimulation. With the reduction of the output frequency of the magnetic stimulation system, the output current was increased and the EMG was enhanced accordingly. Compared with the brain magnetic stimulation, sciatic nerve stimulation produced a more significant EMG enhancement response. This indicated that the magnetic stimulation system could effectively modulate the functions of brain and peripheral nerves by driving the coil. This study provides theoretical and experimental guidance for the subsequent optimization and improvement of practical coils, and lays a preliminary theoretical and experimental foundation for the implementation of magnetic stimulation motion control of animal robots.

    Release date: Export PDF Favorites Scan
  • Development of a flexible embedded neurostimulator for animal robots

    The neural stimulator is a core component of animal robots. While the control effect of animal robots is influenced by various factors, the performance of the neural stimulator plays a decisive role in regulating animal robots. In order to optimize animal robots, embedded neural stimulators had been developed using flexible printed circuit board technology. This innovation not only enabled the stimulator to generate parameter-adjustable biphasic current pulses through control signals, but also optimized its carrying mode, material, and size, overcoming the disadvantages of traditional backpack or head-inserted stimulators, which have poor concealment and are prone to infection. Static, in vitro, and in vivo performance tests of the stimulator demonstrated that it not only had precise pulse waveform output capability, but also was lightweight and small in size. It had excellent in vivo performance in both laboratory and outdoor environments. Our study has high practical significance for the application of animal robots.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content