west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Bone Morphing" 2 results
  • BONE MORPHING SYSTEM FOR ROTATIONAL ALIGNMENT IN TOTAL KNEE ARTHROPLASTY

    【Abstract】 Objective To investigate the qual itative rotation al ignment of components in total knee arthroplastyand the accuracy and the effectiveness of Bone Morphing computer assisted system when qual itatively practicing. MethodsFrom November 2002 to June 2003, 21 patients with three compartments osteoarthritis(21 knees) were treated by primarytotal knee arthroplasty after the conservative medical treatment failed, with the assistance of a “Bone Morphing” CeravisionSystem, implanted posterior stabil ized total knee prosthesis. Twenty-one patients included 5 males (5 knees) and 16 females (16knees) with an average age of 72.4 years (64-79 years) . The locations were left knee in 10 cases and right knee in 11 cases. Thepatients suffered from knee pain and l imitation of movement from 2 to 10 years. There were 14 genu varum and 7 genu valgumpreoperatively. The relative preoperative, intraoperative and postoperative data from cl inical check-up, the X-ray films and theintraoperative components rotational al ignment real-time records in CD Rom were analyzed. Results All operative incisionshealed up by first intension. Twenty-one patients were followed up 12-16 months(mean 13.3 months). For the achievement ofproper lower l imb al ignment and normal frontal laxity of knee, rotational al ignment of femoral components was from internalrotation (IR)1° to external rotation (ER) 5°, tibial components from IR 0° to ER 5°. In patients with genu varum, the rotationalal ignment of the femoral components was ER 1°- ER 5°, of tibial components ER 2°- ER 5°. In patients with genu valgum, the rotationalal ignment of femoral components was IR 1°- ER 4°, of tibial components IR 0°-ER 4°. After 3 months of operation, themean flexion angle measured as range of motion (ROM) was 115°(105-130°), the frontal laxsity measured as 0.2-0.5 cm (mean0.27 cm) of internal laxity and 1.0-2.5 cm (mean 1.7 cm) for external laxity, there were no knee pain, paterllar instabil ity or dislocationand abnormal knee frontal laxity. Conclusion Using Bone Morphing computer-assisted system can optimise theindividual components rotation al ignment accurately.

    Release date:2016-09-01 09:09 Export PDF Favorites Scan
  • BONE MORPHING SYSTEM FOR LIGAMENT BALANCEING IN TOTAL KNEE ARTHROPLASTY

    Objective To investigate effectiveness of applying the Bone Morphingbased image-free computer-assisted system for the ligament balancing managementin the total knee arthroplasty (TKA). Methods Between November 2002 and June 2003, twenty-one posterior stabilized total knee prostheses (Ceraver, France) were implanted in 21 patients using the Bone Morphing based image-free Ceravision system.This cohort included 5 men and 16 women with an average age of 72.4 years, two undergoing high tibial osteotomy and 1 undergoing distal femoral osteotomy before. The preoperative deviation was measured by the full-length AP X-rays. The knees were in varus deviation in 14 patients and in valgus deviation in 7 patients, with an average of 2.36°(varus 13°-valgus 13°). The frontal X-rays ofthe knee were assessed, the mean value of the varus force-stress test was 8.47°(varus 2°-varus 20°), and the mean value of the valgus forcestress test was 3.63°(varus 7°-valgus 12°). Results With the Ceravisionrecorded data, the intraoperative alignment was assessed, the mean lower limb axis was 3.33°(varus 12°-valgus 10°),and compared with the preoperative data, the difference was significant (Plt;0.05); the mean value of the varus force-stress test was 6.47°(varus 0°-varus 24°), the mean value of the valgus force-stress test was 4.32°(varus 8°- valgus 15°), and compared with the preoperative data, the difference was significant (Plt;0.05). The post-prosthetic alignment on Ceravision with a deviation of 0.175°(varus 2°- valgus 3°) was compared with the postoperative alignment by the full-length AP X-rays, with a deviation of 0.3°(varus 3.5°-valgus 1.5°), the difference wasn’t significant(Pgt;0.05).The clinical check-up performed 3 months after operation showed that the average range of movement (ROM) was 115°(105-130°), the mean frontal laxity was 0.27 mm(0.2-0.5 mm). The femoral and tibial components were implanted in the satisfactory 3 dimensional position without ligament imbalance in all the patients, andthere were no instability or patella complications.Conclusion Utilization of the Bone Morphing based image-free computer-assisted system can achieve an accurate component 3 dimensional alignment, optimal bone resection, optimal control of surgical decision in releasing the soft tissues, rotating the femoral component to gain an extension/flexion rectangular gap, and managing theligament balancing so as to achieve a satisfactory initial clinical outcome. This system can be routinely used in the TKA.

    Release date:2016-09-01 09:26 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content