west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "CHEN Xiaojun" 5 results
  • Clinical application of iliac myocutaneous flap pedicled with deep circumflex iliac artery in repair of complex defect of lower limb with cavity

    ObjectiveTo explore the effectiveness of iliac myocutaneous flap pedicled with deep circumflex iliac artery (DCIA) on the repair of lower limb composite defect wounds with cavity. MethodsA retrospective analysis of 7 patients with lower limb composite defect wounds treated between March 2017 and September 2020 was conducted, including 4 males and 3 females, aged 24-58 years, with a median age of 37 years. The causes of injury were machine twisting injury in 2 cases, fall from height injury in 2 cases, and traffic accident injury in 3 cases. According to Gustilo-Anderson classification, there were 1 case of type Ⅲa, 4 cases of type Ⅲb, and 2 cases of type Ⅲc (combined with anterior tibial artery rupture); according to AO/Orthopaedic Trauma Association (AO/OTA) classification, there were 2 cases of type 42-C3, 2 cases of type 43-A2, and 3 cases of type 43-B1. The time from injury to admission ranged from 2 to 10 hours, with an average of 6 hours. Tibial bone defect and surrounding soft tissue defect with deep cavity were left after primary emergency debridement. In the second stage, according to the characteristics of the wound, the three-dimensional repair of the composite defect was designed with DCIA embedded iliac myocutaneous flap. The size of the iliac flap was 2.0 cm×2.0 cm×2.0 cm to 7.0 cm×3.0 cm×2.5 cm, and the size of the flap was 12.0 cm×8.0 cm to 21.0 cm×13.0 cm. The internal oblique muscle flap was harvested in size of 3.0 cm×2.0 cm×2.0 cm to 5.5 cm×4.0 cm×4.0 cm. The donor site was primarily closed. ResultsAll the flaps survived after operation, except for 1 case of partial necrosis of the flap edge, which healed after secondary skin grafting, and the donor and recipient wounds healed by first intention. All patients were followed up 16-24 months, with an average of 18 months. The broken end of the bone defect healed well, and the healing time was 8-10 months, with an average of 7.3 months. At last follow-up, the shape of the flap was satisfactory, the texture was soft, and there was no abnormal hair growth, pigmentation, and so on. Only linear scar was left in the donor site, and no complication such as abdominal hernia occurred. According to Paley fracture healing scoring system, bone healing was rated as excellent in 5 cases and good in 2 cases. The limb function was satisfactory, and full weight bearing was achieved at 12-16 months after operation. According to the lower extremity functional scale (LEFS), 6 cases were excellent and 1 case was good. Conclusion The iliac myocutaneous flap pedicled with DCIA is flexible in design and highly free in tissue composition, which can repair the composite defect wound of lower limbs with deep cavity in a three-dimensional way, and repair the limb shape and reconstruct weight-bearing function to the greatest extent.

    Release date: Export PDF Favorites Scan
  • Microarchitecture features and pathology of necrotic region in patients with steroid-induced and alcohol-induced osteonecrosis of femoral head

    ObjectiveTo investigate the pathological and microstructural features of the osteonecrosis samples from subjects with steroid-induced or alcohol-induced osteonecrosis of the femoral head (ONFH).MethodsThirty femoral head bone samples were collected from ONFH patients who underwent total hip arthroplasty between August 2015 and April 2016. There were 22 males and 8 females. The etiology of ONFH was alcohol-induced in 15 patients and steroid-induced in 15 patients. No significant difference of Association Research Circulation Osseous (ARCO) stage was found between alcohol-induced and steroid-induced ONFH (Z=2.143, P=0.143). The femoral head bone samples in different areas (necrosis, sclerosis, and normal) from involved subjects was taken, and gross observation, HE staining were carried out (the rate of empty lacunaes was calculated). The intact femoral head was scanned by Micro-CT and the parameters of bone microstructure were analyzed quantitatively. The parameters included bone volume to total volume (BV/TV), bone surface area to bone volume ratio (BS/BV), bone mineral density (BMD), bone mineral content (BMC), structural model index (SMI), trabecular plate number (Tb. N), trabecular plate thickness (Tb. Th), and trabecular spacing (Tb. Sp).ResultsAs observed in hard tissue slicing of both groups, the integrity of trabecular bone was destructed and cystic lesions left by the bone resorption was replaced by granulation tissues. Significant revascularization was found in granulation tissues of steroid-induced ONFH, but not in the alcohol-induced one. HE staining showed that the bone marrow structure was disordered in both group, as well as bone marrow necrosis and empty bone lacunaes noticed. The structure and integrity of trabecular bone of steroid-induced ONFH was far more severe whereas that of alcohol-induced one were thicker and better. The rate of empty bone lacunae in necrosis area of steroid-induced group was significantly higher than that of alcohol-induced one (P<0.05), but no significant difference was found in sclerotic and normal areas between 2 groups (P>0.05). Micro-CT showed that necrotic and sclerotic areas of both groups were low bone density. Bone structure in the former area was mostly heterogeneous. Further blood-rich granulation tissues formation was observed in the same places of hard tissue slicing, while the sclerotic one wasn’t. The results of quantitative bone structure analysis showed that BV/TV, BMD, BMC, Tb.N, and Tb.Th of the necrotic and sclerotic areas of steroid-induced ONFH were significantly lower than those of alcohol-induced one (P<0.01), BS/BV, SMI, and Tb.Sp of steroid-induced ONFH were significantly higher than those of alcohol-induced one (P<0.01). No significant difference among the indexes above was found in the normal areas of both groups (P>0.05).ConclusionThe integrity of trabecular bone was destroyed in necrotic area of steroid-induced or alcohol-induced ONFH. However, they performed different features of osteonecrosis and contrasted with each other. The steroid-induced ONFH was characterized by multiple " osteolytic bone destruction”, while the alcohol-induced one was manifested by some kinds of " coagulative destruction”.

    Release date:2018-07-12 06:19 Export PDF Favorites Scan
  • Application of wrap-around great toe flap combined with medial plantar artery perforator flap for completely degloved fingers

    Objective To investigate the effectiveness of the wrap-around great toe flap combined with medial plantar artery perforator flap (MPAP) for repairing the completely degloved fingers. Methods Between February 2018 and December 2019, 12 patients with the completely degloved fingers caused by machine strangulation were admitted. There were 9 males and 3 females with a median age of 32 years (range, 18-42 years). The injured finger was index finger in 7 cases, middle finger in 3 cases, and ring finger in 2 cases. The skin was avulsed from the metacarpophalangeal joint level, with the intact tendon and joint. The interval between injury and admission was 1-8 hours (mean, 5 hours). All fingers were taken debridement during the emergency operation. The size of the skin defect ranged from 8.0 cm×5.0 cm to 12.0 cm×7.5 cm. After flap thinning, the wrap-around great toe flap (8.0 m×2.0 cm-12.0 cm×3.5 cm) and MPAP (8.0 cm×4.0 cm-12.0 cm×5.5 cm) were used to repair the degloved finger. The donor sites were repaired with the full-thickness skin graft or the flap. Results All flaps and skin grafts survived completely without significant complications and the wounds at recipient and donor sites healed by first intention. All patients were followed up 12-16 months (mean, 14 months). The texture, appearance, and color of the affected fingers were close to those of normal fingers, and the nails grew normally. At last follow-up, the mean two-point discrimination of the flap was 9 mm (range, 8-10 mm), and the sensation of the injured finger recovered to S3-S4. And 10 cases were rated as excellent and 2 cases as good according to the Michigan Hand Outcomes Questionnaire (MHQ). There was no complication such as pain from walking or skin ulceration at the donor site. The American Orthopaedic Foot and Ankle Society (AOFAS) score was excellent in 9 cases and good in 3 cases. Conclusion Treating for the completely degloved fingers, the wrap-around great toe flap combined with MPAP can obtain good effectiveness in the respect of the sensation, function, and appearance.

    Release date: Export PDF Favorites Scan
  • Application of deep inferior epigastric perforator flap for repair of extreme defects around knee

    Objective To investigate the effectiveness of the deep inferior epigastric perforator (DIEP) flap for extreme defects around the knee. Methods Between June 2017 and December 2018, 15 patients with the extreme defects around the knee were admitted. There were 9 males and 6 females with a median age of 36 years (range, 23-51 years). The etiology was the traffic accident in 7 cases, tumor in 5 cases, and burn in 3 cases. The injured location was left knee in 8 cases and right knee in 7 cases. The size of soft tissue defects ranged from 15 cm×10 cm to 30 cm×20 cm, and all defects complicated with exposure of blood vessels, nerves, tendons, and other tissues. Transverse DIEP flaps with 1-2 vascular pedicles were prepared according to the size of the defect, including 6 cases of single-pedicle flaps and 9 cases of double-pedicle conjoined flaps. According to the depth of the defect, 10 cases of skin flaps were thinned under microscope. The size of the DIEP flaps ranged from 16 cm×10 cm to 32 cm×20 cm; the average thickness was 1.5 cm (range, 0.8-1.8 cm); the average pedicle length was 7.5 cm (range, 5.0-9.0 cm). The donor site was directly sutured. Results One single-pedicle flap developed distal necrosis after operation, and healed after skin grafting; the other skin flaps survived, and the wounds at the donor and recipient sites healed by first intention. All patients were followed up 16-28 months (mean, 24 months). The shape and texture of the flap were satisfactory, and there was no abnormal hair growth or obvious pigmentation. There was only linear scar at the donor site and no complication such as abdominal hernia. The appearance and function of the knee were satisfactory. No recurred tumor was observed, and the scar contracture was released. At last follow-up, 13 cases were excellent and 2 cases were good, according to the Knee Society Score (KSS) criteria. Conclusion The DIEP flap is an ideal alternative for repairing the extreme defects around knee, with a concealed donor site, easy dissection, flexible design, as well as less complication.

    Release date: Export PDF Favorites Scan
  • Application of groin flap combined with medial plantar artery perforator flap for degree Ⅲ-Ⅳ defects of multiple fingers

    Objective To investigate the effectiveness of groin flap combined with medial plantar artery perforator flap (MPAP) for degree Ⅲ-Ⅳ defects of multiple fingers. Methods Between January 2018 and June 2019, 12 patients with degree Ⅲ-Ⅳ defects of multiple fingers caused by crushing were admitted. There were 9 males and 3 females with a median age of 29 years (range, 16-42 years). The mean interval between the injury and admission was 3 hours (range, 1-9 hours). The injured fingers of 7 cases were index and middle fingers, 4 cases were middle and ring fingers, and 1 case was index, middle, and ring fingers. All fingers were taken thorough debridement and covered by the vacuum sealing drainage device during the emergency operation. The mean interval between the debridement and flap repairing was 18 hours (range, 12-36 hours). During the first-stage operation, the iliac bone graft was used to reconstruct bone frame, and the proximal interphalangeal (PIP) joint from the foot was transferred as the digital PIP joint, then the thin groin flap and MPAP were tailored to cover the dorsal and palmar defects, respectively. The size of the groin flap was 7.0 cm×4.5 cm-14.0 cm×9.0 cm, and the size of the MPAP was 8.0 cm×4.5 cm-14.0 cm×6.5 cm. The abdominal donor site was directly sutured, and the foot was repaired with full-thickness skin grafting. The flaps were separated into the finger shape at the second-stage. Results All the flaps survived, and the wounds healed by first intention; the incisions in the donor site healed by first intention, and the skin grafts survived completely. All patients were followed up 12-18 months (mean, 16 months). At last follow-up, the injured finger was similar to the contralateral one in terms of texture, appearance, and color. The mean two-point discrimination was 8 mm (range, 6-10 mm), and the sensate level recovered to the S3-S4. According to the Michigan Hand Outcomes Questionnaire (MHQ), the reconstructed hand function was excellent in 8 cases and good in 4 cases. There was no complication in the donor sites. Conclusion The degree Ⅲ-Ⅳ defects of multiple fingers were repaired by the groin flap and MPAP, and the reconstructed fingers can perform good texture and motion with being sensate, with less sacrifice on the foot.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content